• Input:

    • Capacity: 6000 VA / 5400 W
    • Nominal voltage: 208/220/230/240VAC
    • Voltage range: 110-300 VAC at 50% load, 176-300 VAC at 100% load
    • Frequency range: 46Hz  ~ 54Hz or 56Hz ~ 64Hz
    • Power factor: ≥ 0.99 @ nominal voltage (100% load)
      Output:
    • Output voltage: 208/220/230/240VAC   
    • Voltage regulation : ± 1%
    • Frequency range: 46Hz  ~ 54Hz or 56Hz ~ 64Hz
    • Frequency range(Batt. Mode): 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
    • Current crest ratio: 3:1
    • Harmonic distortion (Linear load): ≤ 3% THD
    • Harmonic distortion (non-linear load): ≤ 5% THD
    • Transfer time: 0 ms
    • Waveform (Batt. Mode): Pure sinewave
      Efficiency:
    • AC mode: 92% 
    • Battery mode: 90%
      Battery:
    • Battery type & number: 12 V/9 Ah 
    • Numbers: 16/20
    • Typical recharge time: 9 hours recover to 90% capacity
    • Charging current: 1A/2A (Adjustable)
      Physical:
    • Dimension: D x W x H (mm)(UPS unit): 500 x 438 x 88
    • Dimension: D x W x H (mm)(battery pack): 580x 438 x 133
    • Net weight (kgs)(UPS unit): 15
    • Net weight (kgs)(battery pack): 61
      Environment:
    • Humidity: 0-95 % RH @ 0- 40°C (non-condensing)
    • Noise level: Less than 55dBA @ 1 Meter
      Management:
    • Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
    • Optional SNMP: Power management from SNMP manager and web browser

     

    Winner Pro Plus Rack 6KR UPS

  • Input:

    • Capacity: 3000 VA / 2700 W
    • Nominal voltage: 110/115/120/127 VAC or 208/220/230/240 VAC
    • Voltage range: 60-145 VAC or 120-300 VAC at 50% load / 90-145 VAC or 180-300 VAC at 100% load
    • Frequency range: 60-70 Hz
    • Power factor: ≥ 0.99 @ nominal voltage (100% load)
      Output:
    • Output voltage: 110/115/120/127 VAC
    • Voltage regulation : ± 1%
    • Frequency range: 47-53 Hz or 57-63 Hz
    • Frequency range(Batt. Mode): 50 Hz or 60 Hz ± 0.5
    • Current crest ratio: 3:1
    • Harmonic distortion (Linear load): ≤ 3% THD
    • Harmonic distortion (non-linear load): ≤ 6% THD
    • Transfer time: 0 ms
    • Waveform (Batt. Mode): Pure sinewave
      Efficiency:
    • AC mode: 90%
    • Battery mode: 88%
      Battery:
    • Battery type & number: 12 V/9 Ah
    • Numbers: 6
    • Typical recharge time: 4 hours recover to 90% capacity
    • Charging current: 1.0A
      Physical:
    • Dimension: D x W x H (mm) (Standart model): 630 x 438 x 88
    • Dimension: D x W x H (mm) (Long run model): 460 x 438 x 88
    • Net weight (kgs)(Standart model): 29,3
    • Net weight (kgs)(Long run model): 14,2
      Environment:
    • Humidity: 20-90 % RH @ 0-40°C (Non-condensing)
    • Noise level: less than 50 dB @ 1 Meter
      Management:
    • Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
    • Optional SNMP: Power management from SNMP manager and web browser

     

    Winner Pro Plus 3k UPS

  •       Input:

    • Capacity: 2000 VA / 1800 W
    • Nominal voltage: 110/115/120/127 VAC or 208/220/230/240 VAC
    • Voltage range: 60-145 VAC or 120-300 VAC at 50% load / 90-145 VAC or 180-300 VAC at 100% load
    • Frequency range: 60-70 Hz
    • Power factor: ≥ 0.99 @ nominal voltage (100% load)
      Output:
    • Output voltage: 110/115/120/127 VAC
    • Voltage regulation : ± 1%
    • Frequency range: 47-53 Hz or 57-63 Hz
    • Frequency range(Batt. Mode): 50 Hz or 60 Hz ± 0.5
    • Current crest ratio: 3:1
    • Harmonic distortion (Linear load): ≤ 3% THD
    • Harmonic distortion (non-linear load): ≤ 6% THD
    • Transfer time: 0 ms
    • Waveform (Batt. Mode): Pure sinewave
      Efficiency:
    • AC mode: 89%
    • Battery mode: 87%
      Battery:
    • Battery type & number: 12 V/9 Ah
    • Numbers: 2/3
    • Typical recharge time: 4 hours recover to 90% capacity
    • Charging current: 1.0A/2.0A (adjustable)
      Indicators:
    • LCD Panel: UPS status, load level, battery level, input/output voltage, discharge timer, fault conditions
      Alarm:
    • Battery mode: Sounding every 4 seconds
    • Low battery Sounding every second
    • Overload: Sounding every 0.5 second
    • Fault: Continuously sounding
      Physical:
    • Dimension: D x W x H (mm)(UPS unit): 421 x 190 x 318(3U)
    • Dimension: D x W x H (mm)(battery pack): 580 x 438 x 133(3U)
    • Net weight (kgs)(UPS unit): 26.2
    • Net weight (kgs)(battery pack): 6.8
      Environment:
    • Humidity: 20-90 % RH @ 0-40°C (Non-condensing)
    • Noise level: less than 50 dB
      Management:
    • Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
    • Optional SNMP: Power management from SNMP manager and web browser

     

    Winner Pro Plus 2k UPS

  •  

    Input:

    • Capacity: 10000 VA / 9000 W
    • Nominal Voltage: 3×400 VAC (3Ph+N)
    • Frequency range: 46-54 Hz or 56-64 Hz

     

    Output:

    • Output voltage: 208/220/230/240 VAC
    • AC voltage regulation (Batt. Mode): ± 1%
    • Frequency range (Batt. Mode):46-54 Hz or 56-64 Hz
    • Current crest ratio: 3:1 (max.)
    • Waveform (Batt. Mode): Pure sinewave

     

    Battery:

    • Battery type: 12 V/7 Ah
    • Typical recharge time: 9 hours recover to 90% capacity
    • Charging Voltage: 273 VDC ± 1% (Based on 20pcs batteries)

     

    Indicators:

    • LCD Display: UPS status, Load level, Input/Output voltage, Discharge timer, and Fault conditions 

     

    Alarm:

    • Battery mode: Sounding every 4 seconds
    • Low battery Sounding every second
    • Overload: Sounding twice every second
    • Fault: Continuously sounding

     

    Physical:

    • Dimension: D x W x H (mm): 592x250x576
    • Net weight (kgs): 83

     

    Galleon 3P-10K-80K-Family UPS

  • Input:

    • Capacity: 6000VA / 5400W 6K(L), 10000 VA / 9000 W 10K(L)
    • Nominal voltage: 208/220/230/240 VAC
    • Voltage range: 110-300 VAC at 50% load or 176-300 VAC 100% load
    • Frequency range: 46~54 Hz or 56~64 Hz
    • Power factor: ≥ 0.99 @ nominal voltage (100% load)
      Output:
    • Output voltage: 208/220/230/240 VAC  
    • Voltage regulation : ± 1%
    • Frequency range: 46~54 Hz or 56~64 Hz
    • Frequency range(Batt. Mode): 50 Hz or 60Hz ± 0.1 Hz
    • Current crest ratio: 3:1
    • Harmonic distortion (Linear load): ≤ 3% THD
    • Harmonic distortion (non-linear load): ≤ 5% THD
    • Transfer time: 0 ms
    • Waveform (Batt. Mode): Pure sinewave
      Efficiency:
    • AC mode: 92% 6K(L), 93% 10K(L)
    • Battery mode: 90% 6K(L), 91% 10K(L)
      Battery:
    • Battery type & number: 12 V/9 Ah 
    • Numbers: 16/20
    • Typical recharge time: 9 hours recover to 90% capacity
    • Charging current: 1A/2A (adjustable)
      Indicators:
    • LCD Panel: UPS status, load level, battery level, input/output voltage, discharge timer, fault conditions
      Alarm:
    • Battery mode: Sounding every 4 seconds
    • Low battery Sounding every second
    • Overload: Sounding every 0.5 second
    • Fault: Continuously sounding
      Physical:
    • Dimension: D x W x H (mm)(UPS unit): 369 x 190 x 688  6K(L), 442 x 190 x 688 10K(L)
    • Dimension: D x W x H (mm)(battery pack): 369 x 190 x 318 6K(L), 442 x 190 x 318 10K(L) 
    • Net weight (kgs)(UPS unit): 61 6K(L), 74 10K(L)
    • Net weight (kgs)(battery pack): 12 6K(L), 16 10K(L)
      Environment:
    • Humidity: 0-95 % RH @ 0-50°C (Non-condensing) 6K(L),  0-95 % RH @ 0-50°C (Non-condensing) 10K(L)
    • Noise level: less than 55 dB 6K(L),  less than 55 dB 10K(L)
      Management:
    • Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
    • Optional SNMP: Power management from SNMP manager and web browser

     

    Winner Pro Plus 6K(L) UPS

  • Input:

    • Capacity: 3000 VA / 2700 W
    • Nominal voltage: 110/115/120/127VAC or 208/220/230/240VAC
    • Voltage range:  60-145 VAC  or 120-300 VAC at 50% load, 90-145 VAC or 180-300 VAC at 100% load
    • Frequency range: 40Hz  ~ 70 Hz
    • Power factor: ≥ 0.99 @ nominal voltage (100% load)
      Output:
    • Output voltage: 110/115/120/127VAC or 208/220/230/240VAC   
    • Voltage regulation : ± 1%
    • Frequency range: 47~ 53 Hz or 57 ~ 63 Hz
    • Frequency range(Batt. Mode): 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
    • Current crest ratio: 3:1
    • Harmonic distortion (Linear load): ≤ 3% THD
    • Harmonic distortion (non-linear load): ≤ 6% THD
    • Transfer time: 0 ms
    • Waveform (Batt. Mode): Pure sinewave
      Efficiency:
    • AC mode: 90% 
    • Battery mode: 88%
      Battery:
    • Battery type & number: 12 V/9 Ah 
    • Numbers: 6
    • Typical recharge time: 4 hours recover to 90% capacity
    • Charging current: 1.0A
      Physical:
    • Dimension: D x W x H (mm)(UPS unit): 630 x 438 x 88
    • Dimension: D x W x H (mm)(battery pack): 630 x 438 x 88
    • Net weight (kgs)(UPS unit): 29.3
    • Net weight (kgs)(battery pack): 14.2
      Environment:
    • Humidity: 20-90 % RH @ 0- 40°C (non-condensing)
    • Noise level: Less than 50dBA @ 1 Meter
      Management:
    • Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
    • Optional SNMP: Power management from SNMP manager and web browser

     

    Winner Pro Plus-Rack 3K-ZR6-R UPS

  •  Input:

    • Capacity: 1000 VA / 600 W
    • Voltage: 110/120 VAC or 220/230/240 VAC
    • Voltage range: 81-145 Vac / 162-290 VAC
    • Frequency range: 60-50 Hz (auto sensing)Output:
    • Output voltage: 110/120 or 220/230/240 VAC
    • AC voltage regulation (Batt. Mode): ± 10%
    • Frequency range (Batt. Mode): 50 Hz or 60 Hz ± 1 Hz
    • Transfer time: Typical 2-3 ms
    • Waveform (Batt. Mode): Simulated sinewave

      Battery:
    • Battery type & number: 12 V/7 Ah x 2
    • Typical recharge time: 4-6 hours recover to 90% capacity

      Protection:
    • Full protection: overload, discharge and overcharge protection

      Indicators:
    • AC mode: Green lighting
    • Battery mode: Green lighting
    • Fault: N/A

      Alarm:
    • Battery mode: Sounding every 10 seconds
    • Low battery Sounding every second
    • Overload: Sounding every 0.5 second
    • Fault: Continuously sounding

      Physical:
    • Dimension: D x W x H (mm): 320 x 130 x 182
    • Net weight (kgs): 8.2

      Environment:

    • Humidity: 0-90 % RH @ 0-40°C (non-condensing)
    • Noise leverl: less than 40 dB

    Apex03-1K-3 LED UPS

  • Input:

    • Capacity: 2000 VA / 1200 W
    • Voltage: 110/120 VAC or 220/230/240 VAC
    • Voltage range: 81-145 Vac / 162-290 VAC
    • Frequency range: 60-50 Hz (auto sensing)

      Output:
    • Output voltage: 110/120 or 220/230/240 VAC
    • AC voltage regulation (Batt. Mode): ± 10%
    • Frequency range (Batt. Mode): 50 Hz or 60 Hz ± 1 Hz
    • Transfer time: Typical 2-3 ms
    • Waveform (Batt. Mode): Simulated sinewave

      Battery:
    • Battery type & number: 12 V/9 Ah x 2
    • Typical recharge time: 4-6 hours recover to 90% capacity

      Protection:
    • Full protection: overload, discharge and overcharge protection

      Indicators:
    • AC mode: Green lighting
    • Battery mode: Yellow flashing
    • Fault: Red lighting

      Alarm:
    • Battery mode: Sounding every 10 seconds
    • Low battery Sounding every second
    • Overload: Sounding every 0.5 second
    • Fault: Continuously sounding

      Physical:
    • Dimension: D x W x H (mm): 320 x 130 x 182
    • Net weight (kgs): 10.6

      Environment:
    • Humidity: 0-90 % RH @ 0-40°C (non-condensing)
    • Noise leverl: less than 40 dB

    Apex14-2K-3LED UPS

  • Input:

    • Capacity: 10000 VA / 8000 W
    • Voltage: 208/220/230/240 VAC
    • Voltage range: 110-300 VAC ± 3% at 50% load / 176-300 VAC ± 3% at 100% load
    • Frequency range: 46~54 or 56~64 Hz
    • Power factor: ≥ 0.99 @ nominal voltage (100% load)
      Output:
    • Output voltage: 208/220/230/240 VAC
    • Voltage regulation : ± 1%
    • Frequency range: 46~54 or 56~64 Hz
    • Frequency range(Batt. Mode): 50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz
    • Current crest ratio: 3:1
    • Harmonic distortion(Linear load): ≤ 3% THD
    • Harmonic distortion(non-linear load): ≤ 5% THD
    • Transfer time: 0 ms
    • Waveform (Batt. Mode): pure sinewave
      Efficiency:
    • AC mode: 93%
    • Battery mode: 91%
      Battery:
    • Battery type & number: 12 V/9 Ah
    • Numbers:16/20
    • Typical recharge time: 9 hours recover to 90% capacity
    • Charging current: 1A/2A (adjustable)
      Indicators:
    • LCD Panel: UPS status, load level, battery level, input/output voltage, discharge timer, fault conditions
      Alarm:
    • Battery mode: Sounding every 4 seconds
    • Low battery Sounding every second
    • Overload: Sounding every 0.5 second
    • Fault: Continuously sounding
      Physical:
    • Dimension: D x W x H (mm)(UPS unit): 580 x 438 x 133(3U)
    • Dimension: D x W x H (mm)(battery pack): 580 x 438 x 133(3U)
    • Net weight (kgs)(UPS unit): 18
    • Net weight (kgs)(battery pack): 61
      Environment:
    • Humidity: 0-95 % RH @ 0-40°C (non-condensing)
    • Noise level: less than 58 dB
      Management:
    • Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
    • Optional SNMP: Power management from SNMP manager and web browser

    Winner Pro 10K(L) Online UPS

  • No thumb

    MODEL
    Winner Pro+ 1KR(L)

    PHASE
    Single phase with ground

    CAPACITY *
    1000 VA / 900 W

    INPUT

    Nominal Voltage
    110/115/120/127VAC or 208/220/230/240VAC

    Input Voltage Range
    60-145 VAC or 120-300 VAC (Based on load at 50%)
    90-145 VAC or 180-300 VAC (Based on load at 100%)

    Frequency Range
    40 Hz ~ 70 Hz

    Power Factor
    0.99 @ Nominall Voltage (100% load)

    OUTPUT

    Output Voltage
    110/115/120/127VAC or 208/220/230/240VAC

    Voltage Regulation
    ± 1 %

    Frequency Range (Synchronized Range)
    47~ 53 Hz or 57 ~ 63 Hz

    Frequency Range (Batt. Mode)
    50 Hz or 60 Hz ± 0.5%

    Current Crest Ratio
    3:1

    Harmonic Distortion
    3% THD (Linear Load)
    6% THD (Non-linear Load)

    Transfer Time
    AC Mode to Battery Mode
    Zero

    Inverter to Bypass
    4 ms (Typical)

    Waveform (Batt. Mode)
    Pure Sinewave

    EFFICIENCY

    AC Mode
    88%

    Battery Mode
    83%

    BATTERY

    Standard Model
    Battery Type
    12 V / 9 Ah

    Numbers
    2
    3

    Typical Recharge Ti me
    4 hours recover to 90% capacity

    Charging Current ( max.)
    1A

    Charging Voltage
    27.4VDC ± 1%
    41.0VDC ± 1%

    Battery Type
    Depending on applications

    Numbers
    3

    Long-run Model **
    Charging Current ( max.)
    1.0A/2.0A/4.0A/6.0 A

    Charging Voltage
    41.0 VDC ±1%

    INDICATORS

    LCD
    Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

    ALARM

    Battery Mode
    Sounding every 4 seconds

    Low Battery
    Sounding every second

    Overload
    Sounding twice every second

    Fault
    Continuously sounding

    PHYSICAL

    Standard Model
    Dimension, D x W x H (mm)
    310 x 438 x 88
    410 x 438 x 88

    Net Weight (kgs)
    12
    14.1

    Long-run Model **
    Dimension, D x W x H (mm)
    310 x 438 x 88

    Net Weight (kgs)
    9

    ENVIRONMENT

    Humi dity
    20-90 % RH @ 0- 40°C (No n-condensing)

    Noise Level
    Less than 50dB @ 1 Meter

    MANAGEMENT

    S mart RS-232 / USB
    Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC

    Optional SNMP
    Power management from SNMP manager and web browser

    Winner Pro Plus Rack 1KR UPS

  • No thumb

    MODEL
    Winner Pro+ 2KR(L)

    PHASE
    Single phase with ground

    CAPACITY *
    2000 VA / 1800 W

    INPUT

    Nominal Voltage
    110/115/120/127VAC or 208/220/230/240VAC

    Input Voltage Range
    60-145 VAC or 120-300 VAC (Based on load at 50%)
    90-145 VAC or 180-300 VAC (Based on load at 100%)

    Frequency Range
    40 Hz ~ 70 Hz

    Power Factor
    0.99 @ Nominall Voltage (100% load)

    OUTPUT

    Output Voltage
    110/115/120/127VAC or 208/220/230/240VAC

    Voltage Regulation
    ± 1 %

    Frequency Range (Synchronized Range)
    47~ 53 Hz or 57 ~ 63 Hz

    Frequency Range (Batt. Mode)
    50 Hz or 60 Hz ± 0.5%

    Current Crest Ratio
    3:1

    Harmonic Distortion
    3% THD (Linear Load)
    6% THD (Non-linear Load)

    Transfer Time
    AC Mode to Battery Mode
    Zero

    Inverter to Bypass
    4 ms (Typical)

    Waveform (Batt. Mode)
    Pure Sinewave

    EFFICIENCY

    AC Mode
    89%

    Battery Mode
    87%

    BATTERY

    Standard Model
    Battery Type
    12 V / 9 Ah

    Numbers
    4

    Typical Recharge Ti me
    4 hours recover to 90% capacity

    Charging Current ( max.)
    1A

    Charging Voltage
    54.7 VDC ±1%

    Long-run Model **
    Battery Type
    Depending on applications

    Numbers
    6

    Charging Current ( max.)
    1.0A/2.0A/4.0A/6.0 A

    Charging Voltage
    82.1 VDC ±1%

    INDICATORS

    LCD
    Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

    ALARM

    Battery Mode
    Sounding every 4 seconds

    Low Battery
    Sounding every second

    Overload
    Sounding twice every second

    Fault
    Continuously sounding

    PHYSICAL

    Standard Model
    Dimension, D x W x H (mm)
    410 x 438 x 88

    Net Weight (kgs)
    19

    Long-run Model **
    Dimension, D x W x H (mm)
    410 x 438 x 88

    Net Weight (kgs)
    12

    ENVIRONMENT

    Humi dity
    20-90 % RH @ 0- 40°C (No n-condensing)

    Noise Level
    Less than 50dB @ 1 Meter

    MANAGEMENT

    S mart RS-232 / USB
    Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC

    Optional SNMP
    Power management from SNMP manager and web browser

    Winner Pro Plus Rack 2KR UPS

  • No thumb

    MODEL
    Winner Pro+ 10KR (L)

    PHASE
    Single phase with ground

    CAPACITY *
    10000 VA / 9000 W

    INPUT

    Nominal Voltage
    208/220/230/240VAC

    Input Voltage Range
    110-300 VAC (Based on load at 50%)
    176-300 VAC (Based on load at 100%)

    Frequency Range
    46~54 Hz or 56~64 Hz

    Power Factor
    0.99 @ Nominall Voltage (100% load)

    OUTPUT

    Output Voltage
    208/220/230/240VAC

    Voltage Regulation
    ± 1 %

    Frequency Range (Synchronized Range)
    46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz

    Frequency Range (Batt. Mode)
    50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz

    Current Crest Ratio
    3:1

    Harmonic Distortion
    3% THD (Linear Load)
    5% THD (Non-linear Load)

    Transfer Time
    AC Mode to Battery Mode
    0 ms

    Inverter to Bypass
    0 ms

    Waveform (Batt. Mode)
    Pure Sinewave

    EFFICIENCY

    AC Mode
    93%

    Battery Mode
    91%

    BATTERY

    Standard Model
    Battery Type
    12 V / 9 Ah

    Numbers
    16
    20

    Typical Recharge Time
    9 hours recover to 90% capacity

    Charging Current ( max.)
    1A/2A (Adjustable)

    Charging Voltage
    218.4 VDC±1%
    273VDC ±1%

    Long-run Model **
    Battery Type
    Depending on applications

    Numbers
    16 ~ 20 ( Adjustable)

    Charging Current ( max.)
    1A/2A/4A/6A (Adjustable, 6A is only available for 16 pcs batteries)

    Charging Voltage
    218.4 VDC ± 1% (Based on 16 pcs batteries)

    INDICATORS

    LCD
    Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

    ALARM

    Battery Mode
    Sounding every 4 seconds

    Low Battery
    Sounding every second

    Overload
    Sounding twice every second

    Fault
    Continuously sounding

    PHYSICAL

    Standard Model
    Dimension, D x W x H (mm)
    UPS Unit: 580x438x133[3U]
    Battery Pack: 580x438x133 [3U]

    Net Weight (kgs)
    UPS Unit: 18
    Battery Pack: 51
    UPS Unit: 18
    Battery Pack: 61

    Long-run Model **
    Dimension, D x W x H (mm)
    580 x 438 x 133[3U]

    Net Weight (kgs)
    18

    ENVIRONMENT

    Humi dity
    0-95% RH @ 0-40°C (non-condensing)

    Noise Level
    Less than 55dB @ 1 Meter
    Less than 58dB @ 1 Meter

    MANAGEMENT

    S mart RS-232 / USB
    Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC

    Optional SNMP
    Power management from SNMP manager and web browser

    Winner Pro Plus Rack 10KR UPS

  • No thumb

    MODEL
    Apex 600

    CAPACITY
    600 VA / 360 W

    INPUT

    Voltage
    110/120 VAC or 220/230/240 VAC

    Voltage Range
    81-145 VAC / 162-290 VAC

    Frequency Range
    60/50 Hz (Auto sensing)

    OUTPUT

    Output Voltage
    110/120 VAC or 220/230/240 VAC

    AC Voltage Regulation (Batt. Mode)
    ± 10%

    Frequency Range (Batt. Mode)
    50 Hz or 60 Hz ± 1 Hz

    Transfer Time
    Typical 2-6 ms

    Waveform (Batt. Mode)
    Simulated Sinewave

    BATTERY

    Battery Type & Number
    12 V/7 Ah x 1

    Typical Recharge Time
    4 hours recover to 90% capacity

    PROTECTION

    Full Protection
    Overload, discharge, and overcharge protection

    INDICATORS

    LCD Model
    Input voltage, output voltage, battery capacity, load level and UPS status

    LED Model
    AC Mode
    Green lighting

    Battery Mode
    Green flashing

    Fault
    N/A

    ALARM

    Battery Mode
    Sounding every 10 seconds

    Low Battery
    Sounding every second

    Overload
    Sounding every 0.5 second

    Fault
    Continuously sounding

    PHYSICAL

    LED Model
    Dimension, D x W x H (mm)
    279 x 101 x 142

    Net Weight (kgs)
    4.2

    LCD Model
    Dimension, D x W x H (mm)
    300 x 101 x 142

    Net Weight (kgs)
    4.4

    ENVIRONMENT

    Humidity
    0-90 % RH @ 0- 40°C (Non-condensing)

    Noise Level
    Less than 40dB

    APEX 600VA-3 LED UPS

  • No thumb

    MODEL
    Apex 800

    CAPACITY
    800 VA / 480 W

    INPUT

    Voltage
    110/120 VAC or 220/230/240 VAC

    Voltage Range
    81-145 VAC / 162-290 VAC

    Frequency Range
    60/50 Hz (Auto sensing)

    OUTPUT

    Output Voltage
    110/120 VAC or 220/230/240 VAC

    AC Voltage Regulation (Batt. Mode)
    ± 10%

    Frequency Range (Batt. Mode)
    50 Hz or 60 Hz ± 1 Hz

    Transfer Time
    Typical 2-6 ms

    Waveform (Batt. Mode)
    Simulated Sinewave

    BATTERY

    Battery Type & Number
    12 V/9 Ah x 1

    Typical Recharge Time
    4 hours recover to 90% capacity

    PROTECTION

    Full Protection
    Overload, discharge, and overcharge protection

    INDICATORS

    LCD Model
    Input voltage, output voltage, battery capacity, load level and UPS status

    LED Model
    AC Mode
    Green lighting

    Battery Mode
    Green flashing

    Fault
    N/A

    ALARM

    Battery Mode
    Sounding every 10 seconds

    Low Battery
    Sounding every second

    Overload
    Sounding every 0.5 second

    Fault
    Continuously sounding

    PHYSICAL

    LED Model
    Dimension, D x W x H (mm)
    279 x 101 x 142

    Net Weight (kgs)
    4.9

    LCD Model
    Dimension, D x W x H (mm)
    300 x 101 x 142

    Net Weight (kgs)
    5.0

    ENVIRONMENT

    Humidity
    0-90 % RH @ 0- 40°C (Non-condensing)

    Noise Level
    Less than 40dB

    APEX 800VA -3 LED UPS

  • No thumb

    MODEL
    Apex 1.5K

    CAPACITY
    1500 VA / 900 W

    INPUT

    Voltage
    110/120 VAC or 220/230/240 VAC

    Voltage Range
    81-145 VAC / 162-290 VAC

    Frequency Range
    60/50 Hz (Auto sensing)

    OUTPUT

    Output Voltage
    110/120 VAC or 220/230/240 VAC

    AC Voltage Regulation (Batt. Mode)
    ± 10%

    Frequency Range (Batt. Mode)
    50 Hz or 60 Hz ± 1 Hz

    Transfer Time
    Typical 2-6 ms

    Waveform (Batt. Mode)
    Simulated Sinewave

    BATTERY

    Battery Type & Number
    12 V/9 Ah x 2

    Typical Recharge Time
    4-6 hours recover to 90% capacity

    PROTECTION

    Full Protection
    Overload, discharge, and overcharge protection

    INDICATORS

    LCD Model
    Input voltage, output voltage, battery capacity, load level and UPS status

    LED Model
    AC Mode
    Green lighting

    Battery Mode
    Yellow flashing

    Fault
    Red lighting

    ALARM

    Battery Mode
    Sounding every 10 seconds

    Low Battery
    Sounding every second

    Overload
    Sounding every 0.5 second

    Fault
    Continuously sounding

    PHYSICAL

    LED Model
    Dimension, D x W x H (mm)
    320 x 130 x 182

    Net Weight (kgs)
    10.6

    LCD Model
    Dimension, D x W x H (mm)
    320 x 130 x 182

    Net Weight (kgs)
    10.6

    ENVIRONMENT

    Humidity
    0-90 % RH @ 0- 40°C (Non-condensing)

    Noise Level
    Less than 40dB

    APEX 1500VA – 3 LED UPS