APEX 1500VA – 3 LED UPS
MODEL
Apex 1.5KCAPACITY
1500 VA / 900 WINPUT
Voltage
110/120 VAC or 220/230/240 VACVoltage Range
81-145 VAC / 162-290 VACFrequency Range
60/50 Hz (Auto sensing)OUTPUT
Output Voltage
110/120 VAC or 220/230/240 VACAC Voltage Regulation (Batt. Mode)
± 10%Frequency Range (Batt. Mode)
50 Hz or 60 Hz ± 1 HzTransfer Time
Typical 2-6 msWaveform (Batt. Mode)
Simulated SinewaveBATTERY
Battery Type & Number
12 V/9 Ah x 2Typical Recharge Time
4-6 hours recover to 90% capacityPROTECTION
Full Protection
Overload, discharge, and overcharge protectionINDICATORS
LCD Model
Input voltage, output voltage, battery capacity, load level and UPS statusLED Model
AC Mode
Green lightingBattery Mode
Yellow flashingFault
Red lightingALARM
Battery Mode
Sounding every 10 secondsLow Battery
Sounding every secondOverload
Sounding every 0.5 secondFault
Continuously soundingPHYSICAL
LED Model
Dimension, D x W x H (mm)
320 x 130 x 182Net Weight (kgs)
10.6LCD Model
Dimension, D x W x H (mm)
320 x 130 x 182Net Weight (kgs)
10.6ENVIRONMENT
Humidity
0-90 % RH @ 0- 40°C (Non-condensing)Noise Level
Less than 40dB -
APEX 600VA-3 LED UPS
MODEL
Apex 600CAPACITY
600 VA / 360 WINPUT
Voltage
110/120 VAC or 220/230/240 VACVoltage Range
81-145 VAC / 162-290 VACFrequency Range
60/50 Hz (Auto sensing)OUTPUT
Output Voltage
110/120 VAC or 220/230/240 VACAC Voltage Regulation (Batt. Mode)
± 10%Frequency Range (Batt. Mode)
50 Hz or 60 Hz ± 1 HzTransfer Time
Typical 2-6 msWaveform (Batt. Mode)
Simulated SinewaveBATTERY
Battery Type & Number
12 V/7 Ah x 1Typical Recharge Time
4 hours recover to 90% capacityPROTECTION
Full Protection
Overload, discharge, and overcharge protectionINDICATORS
LCD Model
Input voltage, output voltage, battery capacity, load level and UPS statusLED Model
AC Mode
Green lightingBattery Mode
Green flashingFault
N/AALARM
Battery Mode
Sounding every 10 secondsLow Battery
Sounding every secondOverload
Sounding every 0.5 secondFault
Continuously soundingPHYSICAL
LED Model
Dimension, D x W x H (mm)
279 x 101 x 142Net Weight (kgs)
4.2LCD Model
Dimension, D x W x H (mm)
300 x 101 x 142Net Weight (kgs)
4.4ENVIRONMENT
Humidity
0-90 % RH @ 0- 40°C (Non-condensing)Noise Level
Less than 40dB -
APEX 800VA -3 LED UPS
MODEL
Apex 800CAPACITY
800 VA / 480 WINPUT
Voltage
110/120 VAC or 220/230/240 VACVoltage Range
81-145 VAC / 162-290 VACFrequency Range
60/50 Hz (Auto sensing)OUTPUT
Output Voltage
110/120 VAC or 220/230/240 VACAC Voltage Regulation (Batt. Mode)
± 10%Frequency Range (Batt. Mode)
50 Hz or 60 Hz ± 1 HzTransfer Time
Typical 2-6 msWaveform (Batt. Mode)
Simulated SinewaveBATTERY
Battery Type & Number
12 V/9 Ah x 1Typical Recharge Time
4 hours recover to 90% capacityPROTECTION
Full Protection
Overload, discharge, and overcharge protectionINDICATORS
LCD Model
Input voltage, output voltage, battery capacity, load level and UPS statusLED Model
AC Mode
Green lightingBattery Mode
Green flashingFault
N/AALARM
Battery Mode
Sounding every 10 secondsLow Battery
Sounding every secondOverload
Sounding every 0.5 secondFault
Continuously soundingPHYSICAL
LED Model
Dimension, D x W x H (mm)
279 x 101 x 142Net Weight (kgs)
4.9LCD Model
Dimension, D x W x H (mm)
300 x 101 x 142Net Weight (kgs)
5.0ENVIRONMENT
Humidity
0-90 % RH @ 0- 40°C (Non-condensing)Noise Level
Less than 40dB -
Apex03-1K-3 LED UPS
Input:
- Capacity: 1000 VA / 600 W
- Voltage: 110/120 VAC or 220/230/240 VAC
- Voltage range: 81-145 Vac / 162-290 VAC
- Frequency range: 60-50 Hz (auto sensing)Output:
- Output voltage: 110/120 or 220/230/240 VAC
- AC voltage regulation (Batt. Mode): ± 10%
- Frequency range (Batt. Mode): 50 Hz or 60 Hz ± 1 Hz
- Transfer time: Typical 2-3 ms
- Waveform (Batt. Mode): Simulated sinewave
Battery:
- Battery type & number: 12 V/7 Ah x 2
- Typical recharge time: 4-6 hours recover to 90% capacity
Protection:
- Full protection: overload, discharge and overcharge protection
Indicators:
- AC mode: Green lighting
- Battery mode: Green lighting
- Fault: N/A
Alarm:
- Battery mode: Sounding every 10 seconds
- Low battery Sounding every second
- Overload: Sounding every 0.5 second
- Fault: Continuously sounding
Physical:
- Dimension: D x W x H (mm): 320 x 130 x 182
- Net weight (kgs): 8.2
Environment:
- Humidity: 0-90 % RH @ 0-40°C (non-condensing)
- Noise leverl: less than 40 dB
- Capacity: 1000 VA / 600 W
-
Apex14-2K-3LED UPS
Input:
- Capacity: 2000 VA / 1200 W
- Voltage: 110/120 VAC or 220/230/240 VAC
- Voltage range: 81-145 Vac / 162-290 VAC
- Frequency range: 60-50 Hz (auto sensing)
Output:
- Output voltage: 110/120 or 220/230/240 VAC
- AC voltage regulation (Batt. Mode): ± 10%
- Frequency range (Batt. Mode): 50 Hz or 60 Hz ± 1 Hz
- Transfer time: Typical 2-3 ms
- Waveform (Batt. Mode): Simulated sinewave
Battery:
- Battery type & number: 12 V/9 Ah x 2
- Typical recharge time: 4-6 hours recover to 90% capacity
Protection:
- Full protection: overload, discharge and overcharge protection
Indicators:
- AC mode: Green lighting
- Battery mode: Yellow flashing
- Fault: Red lighting
Alarm:
- Battery mode: Sounding every 10 seconds
- Low battery Sounding every second
- Overload: Sounding every 0.5 second
- Fault: Continuously sounding
Physical:
- Dimension: D x W x H (mm): 320 x 130 x 182
- Net weight (kgs): 10.6
Environment:
- Humidity: 0-90 % RH @ 0-40°C (non-condensing)
- Noise leverl: less than 40 dB
- Capacity: 2000 VA / 1200 W
-
Galleon 3P-10K-80K-Family UPS
Input:
- Capacity: 10000 VA / 9000 W
- Nominal Voltage: 3×400 VAC (3Ph+N)
- Frequency range: 46-54 Hz or 56-64 Hz
Output:
- Output voltage: 208/220/230/240 VAC
- AC voltage regulation (Batt. Mode): ± 1%
- Frequency range (Batt. Mode):46-54 Hz or 56-64 Hz
- Current crest ratio: 3:1 (max.)
- Waveform (Batt. Mode): Pure sinewave
Battery:
- Battery type: 12 V/7 Ah
- Typical recharge time: 9 hours recover to 90% capacity
- Charging Voltage: 273 VDC ± 1% (Based on 20pcs batteries)
Indicators:
- LCD Display: UPS status, Load level, Input/Output voltage, Discharge timer, and Fault conditions
Alarm:
- Battery mode: Sounding every 4 seconds
- Low battery Sounding every second
- Overload: Sounding twice every second
- Fault: Continuously sounding
Physical:
- Dimension: D x W x H (mm): 592x250x576
- Net weight (kgs): 83
-
Winner Pro 10K(L) Online UPS
Input:
- Capacity: 10000 VA / 8000 W
- Voltage: 208/220/230/240 VAC
- Voltage range: 110-300 VAC ± 3% at 50% load / 176-300 VAC ± 3% at 100% load
- Frequency range: 46~54 or 56~64 Hz
- Power factor: ≥ 0.99 @ nominal voltage (100% load)
Output:
- Output voltage: 208/220/230/240 VAC
- Voltage regulation : ± 1%
- Frequency range: 46~54 or 56~64 Hz
- Frequency range(Batt. Mode): 50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz
- Current crest ratio: 3:1
- Harmonic distortion(Linear load): ≤ 3% THD
- Harmonic distortion(non-linear load): ≤ 5% THD
- Transfer time: 0 ms
- Waveform (Batt. Mode): pure sinewave
Efficiency:
- AC mode: 93%
- Battery mode: 91%
Battery:
- Battery type & number: 12 V/9 Ah
- Numbers:16/20
- Typical recharge time: 9 hours recover to 90% capacity
- Charging current: 1A/2A (adjustable)
Indicators:
- LCD Panel: UPS status, load level, battery level, input/output voltage, discharge timer, fault conditions
Alarm:
- Battery mode: Sounding every 4 seconds
- Low battery Sounding every second
- Overload: Sounding every 0.5 second
- Fault: Continuously sounding
Physical:
- Dimension: D x W x H (mm)(UPS unit): 580 x 438 x 133(3U)
- Dimension: D x W x H (mm)(battery pack): 580 x 438 x 133(3U)
- Net weight (kgs)(UPS unit): 18
- Net weight (kgs)(battery pack): 61
Environment:
- Humidity: 0-95 % RH @ 0-40°C (non-condensing)
- Noise level: less than 58 dB
Management: - Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
- Optional SNMP: Power management from SNMP manager and web browser
- Capacity: 10000 VA / 8000 W
-
Winner Pro Plus 2k UPS
Input:
- Capacity: 2000 VA / 1800 W
- Nominal voltage: 110/115/120/127 VAC or 208/220/230/240 VAC
- Voltage range: 60-145 VAC or 120-300 VAC at 50% load / 90-145 VAC or 180-300 VAC at 100% load
- Frequency range: 60-70 Hz
- Power factor: ≥ 0.99 @ nominal voltage (100% load)
Output: - Output voltage: 110/115/120/127 VAC
- Voltage regulation : ± 1%
- Frequency range: 47-53 Hz or 57-63 Hz
- Frequency range(Batt. Mode): 50 Hz or 60 Hz ± 0.5
- Current crest ratio: 3:1
- Harmonic distortion (Linear load): ≤ 3% THD
- Harmonic distortion (non-linear load): ≤ 6% THD
- Transfer time: 0 ms
- Waveform (Batt. Mode): Pure sinewave
Efficiency: - AC mode: 89%
- Battery mode: 87%
Battery: - Battery type & number: 12 V/9 Ah
- Numbers: 2/3
- Typical recharge time: 4 hours recover to 90% capacity
- Charging current: 1.0A/2.0A (adjustable)
Indicators: - LCD Panel: UPS status, load level, battery level, input/output voltage, discharge timer, fault conditions
Alarm: - Battery mode: Sounding every 4 seconds
- Low battery Sounding every second
- Overload: Sounding every 0.5 second
- Fault: Continuously sounding
Physical: - Dimension: D x W x H (mm)(UPS unit): 421 x 190 x 318(3U)
- Dimension: D x W x H (mm)(battery pack): 580 x 438 x 133(3U)
- Net weight (kgs)(UPS unit): 26.2
- Net weight (kgs)(battery pack): 6.8
Environment: - Humidity: 20-90 % RH @ 0-40°C (Non-condensing)
- Noise level: less than 50 dB
Management: - Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
- Optional SNMP: Power management from SNMP manager and web browser
-
Winner Pro Plus 3k UPS
Input:
- Capacity: 3000 VA / 2700 W
- Nominal voltage: 110/115/120/127 VAC or 208/220/230/240 VAC
- Voltage range: 60-145 VAC or 120-300 VAC at 50% load / 90-145 VAC or 180-300 VAC at 100% load
- Frequency range: 60-70 Hz
- Power factor: ≥ 0.99 @ nominal voltage (100% load)
Output: - Output voltage: 110/115/120/127 VAC
- Voltage regulation : ± 1%
- Frequency range: 47-53 Hz or 57-63 Hz
- Frequency range(Batt. Mode): 50 Hz or 60 Hz ± 0.5
- Current crest ratio: 3:1
- Harmonic distortion (Linear load): ≤ 3% THD
- Harmonic distortion (non-linear load): ≤ 6% THD
- Transfer time: 0 ms
- Waveform (Batt. Mode): Pure sinewave
Efficiency: - AC mode: 90%
- Battery mode: 88%
Battery: - Battery type & number: 12 V/9 Ah
- Numbers: 6
- Typical recharge time: 4 hours recover to 90% capacity
- Charging current: 1.0A
Physical: - Dimension: D x W x H (mm) (Standart model): 630 x 438 x 88
- Dimension: D x W x H (mm) (Long run model): 460 x 438 x 88
- Net weight (kgs)(Standart model): 29,3
- Net weight (kgs)(Long run model): 14,2
Environment: - Humidity: 20-90 % RH @ 0-40°C (Non-condensing)
- Noise level: less than 50 dB @ 1 Meter
Management: - Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
- Optional SNMP: Power management from SNMP manager and web browser
-
Winner Pro Plus 6K(L) UPS
Input:
- Capacity: 6000VA / 5400W 6K(L), 10000 VA / 9000 W 10K(L)
- Nominal voltage: 208/220/230/240 VAC
- Voltage range: 110-300 VAC at 50% load or 176-300 VAC 100% load
- Frequency range: 46~54 Hz or 56~64 Hz
- Power factor: ≥ 0.99 @ nominal voltage (100% load)
Output: - Output voltage: 208/220/230/240 VAC
- Voltage regulation : ± 1%
- Frequency range: 46~54 Hz or 56~64 Hz
- Frequency range(Batt. Mode): 50 Hz or 60Hz ± 0.1 Hz
- Current crest ratio: 3:1
- Harmonic distortion (Linear load): ≤ 3% THD
- Harmonic distortion (non-linear load): ≤ 5% THD
- Transfer time: 0 ms
- Waveform (Batt. Mode): Pure sinewave
Efficiency: - AC mode: 92% 6K(L), 93% 10K(L)
- Battery mode: 90% 6K(L), 91% 10K(L)
Battery: - Battery type & number: 12 V/9 Ah
- Numbers: 16/20
- Typical recharge time: 9 hours recover to 90% capacity
- Charging current: 1A/2A (adjustable)
Indicators: - LCD Panel: UPS status, load level, battery level, input/output voltage, discharge timer, fault conditions
Alarm: - Battery mode: Sounding every 4 seconds
- Low battery Sounding every second
- Overload: Sounding every 0.5 second
- Fault: Continuously sounding
Physical: - Dimension: D x W x H (mm)(UPS unit): 369 x 190 x 688 6K(L), 442 x 190 x 688 10K(L)
- Dimension: D x W x H (mm)(battery pack): 369 x 190 x 318 6K(L), 442 x 190 x 318 10K(L)
- Net weight (kgs)(UPS unit): 61 6K(L), 74 10K(L)
- Net weight (kgs)(battery pack): 12 6K(L), 16 10K(L)
Environment: - Humidity: 0-95 % RH @ 0-50°C (Non-condensing) 6K(L), 0-95 % RH @ 0-50°C (Non-condensing) 10K(L)
- Noise level: less than 55 dB 6K(L), less than 55 dB 10K(L)
Management: - Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
- Optional SNMP: Power management from SNMP manager and web browser
-
Winner Pro Plus Rack 10KR UPS
MODEL
Winner Pro+ 10KR (L)PHASE
Single phase with groundCAPACITY *
10000 VA / 9000 WINPUT
Nominal Voltage
208/220/230/240VACInput Voltage Range
110-300 VAC (Based on load at 50%)
176-300 VAC (Based on load at 100%)Frequency Range
46~54 Hz or 56~64 HzPower Factor
0.99 @ Nominall Voltage (100% load)OUTPUT
Output Voltage
208/220/230/240VACVoltage Regulation
± 1 %Frequency Range (Synchronized Range)
46 Hz ~ 54 Hz or 56 Hz ~ 64 HzFrequency Range (Batt. Mode)
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio
3:1Harmonic Distortion
3% THD (Linear Load)
5% THD (Non-linear Load)Transfer Time
AC Mode to Battery Mode
0 msInverter to Bypass
0 msWaveform (Batt. Mode)
Pure SinewaveEFFICIENCY
AC Mode
93%Battery Mode
91%BATTERY
Standard Model
Battery Type
12 V / 9 AhNumbers
16
20Typical Recharge Time
9 hours recover to 90% capacityCharging Current ( max.)
1A/2A (Adjustable)Charging Voltage
218.4 VDC±1%
273VDC ±1%Long-run Model **
Battery Type
Depending on applicationsNumbers
16 ~ 20 ( Adjustable)Charging Current ( max.)
1A/2A/4A/6A (Adjustable, 6A is only available for 16 pcs batteries)Charging Voltage
218.4 VDC ± 1% (Based on 16 pcs batteries)INDICATORS
LCD
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicatorsALARM
Battery Mode
Sounding every 4 secondsLow Battery
Sounding every secondOverload
Sounding twice every secondFault
Continuously soundingPHYSICAL
Standard Model
Dimension, D x W x H (mm)
UPS Unit: 580x438x133[3U]
Battery Pack: 580x438x133 [3U]Net Weight (kgs)
UPS Unit: 18
Battery Pack: 51
UPS Unit: 18
Battery Pack: 61Long-run Model **
Dimension, D x W x H (mm)
580 x 438 x 133[3U]Net Weight (kgs)
18ENVIRONMENT
Humi dity
0-95% RH @ 0-40°C (non-condensing)Noise Level
Less than 55dB @ 1 Meter
Less than 58dB @ 1 MeterMANAGEMENT
S mart RS-232 / USB
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MACOptional SNMP
Power management from SNMP manager and web browser -
Winner Pro Plus Rack 1KR UPS
MODEL
Winner Pro+ 1KR(L)PHASE
Single phase with groundCAPACITY *
1000 VA / 900 WINPUT
Nominal Voltage
110/115/120/127VAC or 208/220/230/240VACInput Voltage Range
60-145 VAC or 120-300 VAC (Based on load at 50%)
90-145 VAC or 180-300 VAC (Based on load at 100%)Frequency Range
40 Hz ~ 70 HzPower Factor
0.99 @ Nominall Voltage (100% load)OUTPUT
Output Voltage
110/115/120/127VAC or 208/220/230/240VACVoltage Regulation
± 1 %Frequency Range (Synchronized Range)
47~ 53 Hz or 57 ~ 63 HzFrequency Range (Batt. Mode)
50 Hz or 60 Hz ± 0.5%Current Crest Ratio
3:1Harmonic Distortion
3% THD (Linear Load)
6% THD (Non-linear Load)Transfer Time
AC Mode to Battery Mode
ZeroInverter to Bypass
4 ms (Typical)Waveform (Batt. Mode)
Pure SinewaveEFFICIENCY
AC Mode
88%Battery Mode
83%BATTERY
Standard Model
Battery Type
12 V / 9 AhNumbers
2
3Typical Recharge Ti me
4 hours recover to 90% capacityCharging Current ( max.)
1ACharging Voltage
27.4VDC ± 1%
41.0VDC ± 1%Battery Type
Depending on applicationsNumbers
3Long-run Model **
Charging Current ( max.)
1.0A/2.0A/4.0A/6.0 ACharging Voltage
41.0 VDC ±1%INDICATORS
LCD
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicatorsALARM
Battery Mode
Sounding every 4 secondsLow Battery
Sounding every secondOverload
Sounding twice every secondFault
Continuously soundingPHYSICAL
Standard Model
Dimension, D x W x H (mm)
310 x 438 x 88
410 x 438 x 88Net Weight (kgs)
12
14.1Long-run Model **
Dimension, D x W x H (mm)
310 x 438 x 88Net Weight (kgs)
9ENVIRONMENT
Humi dity
20-90 % RH @ 0- 40°C (No n-condensing)Noise Level
Less than 50dB @ 1 MeterMANAGEMENT
S mart RS-232 / USB
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MACOptional SNMP
Power management from SNMP manager and web browser -
Winner Pro Plus Rack 2KR UPS
MODEL
Winner Pro+ 2KR(L)PHASE
Single phase with groundCAPACITY *
2000 VA / 1800 WINPUT
Nominal Voltage
110/115/120/127VAC or 208/220/230/240VACInput Voltage Range
60-145 VAC or 120-300 VAC (Based on load at 50%)
90-145 VAC or 180-300 VAC (Based on load at 100%)Frequency Range
40 Hz ~ 70 HzPower Factor
0.99 @ Nominall Voltage (100% load)OUTPUT
Output Voltage
110/115/120/127VAC or 208/220/230/240VACVoltage Regulation
± 1 %Frequency Range (Synchronized Range)
47~ 53 Hz or 57 ~ 63 HzFrequency Range (Batt. Mode)
50 Hz or 60 Hz ± 0.5%Current Crest Ratio
3:1Harmonic Distortion
3% THD (Linear Load)
6% THD (Non-linear Load)Transfer Time
AC Mode to Battery Mode
ZeroInverter to Bypass
4 ms (Typical)Waveform (Batt. Mode)
Pure SinewaveEFFICIENCY
AC Mode
89%Battery Mode
87%BATTERY
Standard Model
Battery Type
12 V / 9 AhNumbers
4Typical Recharge Ti me
4 hours recover to 90% capacityCharging Current ( max.)
1ACharging Voltage
54.7 VDC ±1%Long-run Model **
Battery Type
Depending on applicationsNumbers
6Charging Current ( max.)
1.0A/2.0A/4.0A/6.0 ACharging Voltage
82.1 VDC ±1%INDICATORS
LCD
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicatorsALARM
Battery Mode
Sounding every 4 secondsLow Battery
Sounding every secondOverload
Sounding twice every secondFault
Continuously soundingPHYSICAL
Standard Model
Dimension, D x W x H (mm)
410 x 438 x 88Net Weight (kgs)
19Long-run Model **
Dimension, D x W x H (mm)
410 x 438 x 88Net Weight (kgs)
12ENVIRONMENT
Humi dity
20-90 % RH @ 0- 40°C (No n-condensing)Noise Level
Less than 50dB @ 1 MeterMANAGEMENT
S mart RS-232 / USB
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MACOptional SNMP
Power management from SNMP manager and web browser -
Winner Pro Plus Rack 6KR UPS
Input:
- Capacity: 6000 VA / 5400 W
- Nominal voltage: 208/220/230/240VAC
- Voltage range: 110-300 VAC at 50% load, 176-300 VAC at 100% load
- Frequency range: 46Hz ~ 54Hz or 56Hz ~ 64Hz
- Power factor: ≥ 0.99 @ nominal voltage (100% load)
Output: - Output voltage: 208/220/230/240VAC
- Voltage regulation : ± 1%
- Frequency range: 46Hz ~ 54Hz or 56Hz ~ 64Hz
- Frequency range(Batt. Mode): 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
- Current crest ratio: 3:1
- Harmonic distortion (Linear load): ≤ 3% THD
- Harmonic distortion (non-linear load): ≤ 5% THD
- Transfer time: 0 ms
- Waveform (Batt. Mode): Pure sinewave
Efficiency: - AC mode: 92%
- Battery mode: 90%
Battery: - Battery type & number: 12 V/9 Ah
- Numbers: 16/20
- Typical recharge time: 9 hours recover to 90% capacity
- Charging current: 1A/2A (Adjustable)
Physical: - Dimension: D x W x H (mm)(UPS unit): 500 x 438 x 88
- Dimension: D x W x H (mm)(battery pack): 580x 438 x 133
- Net weight (kgs)(UPS unit): 15
- Net weight (kgs)(battery pack): 61
Environment: - Humidity: 0-95 % RH @ 0- 40°C (non-condensing)
- Noise level: Less than 55dBA @ 1 Meter
Management: - Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
- Optional SNMP: Power management from SNMP manager and web browser
-
Winner Pro Plus-Rack 3K-ZR6-R UPS
Input:
- Capacity: 3000 VA / 2700 W
- Nominal voltage: 110/115/120/127VAC or 208/220/230/240VAC
- Voltage range: 60-145 VAC or 120-300 VAC at 50% load, 90-145 VAC or 180-300 VAC at 100% load
- Frequency range: 40Hz ~ 70 Hz
- Power factor: ≥ 0.99 @ nominal voltage (100% load)
Output: - Output voltage: 110/115/120/127VAC or 208/220/230/240VAC
- Voltage regulation : ± 1%
- Frequency range: 47~ 53 Hz or 57 ~ 63 Hz
- Frequency range(Batt. Mode): 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
- Current crest ratio: 3:1
- Harmonic distortion (Linear load): ≤ 3% THD
- Harmonic distortion (non-linear load): ≤ 6% THD
- Transfer time: 0 ms
- Waveform (Batt. Mode): Pure sinewave
Efficiency: - AC mode: 90%
- Battery mode: 88%
Battery: - Battery type & number: 12 V/9 Ah
- Numbers: 6
- Typical recharge time: 4 hours recover to 90% capacity
- Charging current: 1.0A
Physical: - Dimension: D x W x H (mm)(UPS unit): 630 x 438 x 88
- Dimension: D x W x H (mm)(battery pack): 630 x 438 x 88
- Net weight (kgs)(UPS unit): 29.3
- Net weight (kgs)(battery pack): 14.2
Environment: - Humidity: 20-90 % RH @ 0- 40°C (non-condensing)
- Noise level: Less than 50dBA @ 1 Meter
Management: - Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
- Optional SNMP: Power management from SNMP manager and web browser