Shop

  • Application:

    PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, ATM LAN 1,2 Gbit/s

    Сompliance with the requirements:

    Cable: IEC 61156-5 (cat.5e)

    Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)

    Fire safety: IEC 60332-1, CPR class Eca

    Mechanical characteristics:

    Тemperature range:

    • During installation -10 °C … +60 °C
    • After installation -20 °C … +60 °C

     

    Bending radius:

    • During installation ≥ 8 cable diameters
    • After installation ≥ 4 cable diameters

     

    Tensile stress ≤ 85 N

     

    ELECTRICAL CHARACTERISTICS AT 20 °C:

    Parameter
    Unit
    Value

    Capacitance
    pF/m
    ≤ 56

    Direct current resistance for
    Оhm/km

    conductors with Ø:

    0,51 mm
    ≤ 92

    0,48 mm
    ≤ 103

    0,46 mm
    ≤ 112

    0,44 mm
    ≤ 123

    Insulation resistance
    GOhm*km
    ≥ 5

    Resistance unbalance
    %
    2

    Signal propagation velocity
    s
    0,69

    Characteristic impedance in the
    Ohm
    100±15

    frequency range of: 1-100 MHz

    Test voltage between cores, (DC, 2 s)
    kV
    2,5

     

    Frequency, MHz
    1
    4
    10
    16
    20
    31,25

    Attenuation, dB, max; for max. cable lengths with conductor Ø:
    2,1
    4,1
    6,5
    8,3
    9,3
    11,7

    0,51 mm = 104 m

    0,48 mm = 92 m

    0,46 mm = 84 m

    0,44 mm = 77 m

    NEXT, dB, min
    65,3
    56,3
    50,3
    47,2
    45,8
    42,9

    PS NEXT, dB, min
    62,3
    53,3
    47,3
    44,2
    42,8
    39,9

    ELFEXT, dB, min
    64
    52
    44
    40
    38
    34

    PS ELFEXT, dB, min
    61
    49
    41
    37
    35
    31

    RL, dB, min
    20,0
    23,0
    25,0
    25,0
    25,0
    23,3

    Frequency, MHz
    62,5
    100

    Attenuation, dB, max; for max. cable lengths with conductor Ø:
    17,0
    22,0

    0,51 mm = 104 m

    0,48 mm = 92 m

    0,46 mm = 84 m

    0,44 mm = 77 m

    NEXT, dB, min
    38,4
    35,3

    PS NEXT, dB, min
    35,4
    32,3

    ELFEXT, dB, min
    28
    24

    PS ELFEXT, dB, min
    25
    21

    RL, dB, min
    20,7
    19,0

    IEC 61156-5, values lower than 4 MHz are given for information only

     

     

    LAN Cable CAT5 F/UTP 4x2x24 AWG Indoor

  • Application:

    PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T, 10GBASE-T (under 55 m)

     

    Installation and Operation conditions:

    For outdoor installation in telephone ducts, collectors, mines, on the walls of buildings in conditions of heightened electro-magnetic impacts. Operated on frequencies up to 250 MHz

     

    Compliance with the requirements:

    Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568-C.2

    Cable: IEC 61156-5, EN 50288-5-1

     

    Mechanical characteristics:

    Temperature range:

    • During installation -10 °C … +60 °C
    • After installation -50 °C … +60 °C

    Bending radius:

    • During installation ≥ 8 cable diameters
    • After installation ≥ 4 cable diameters

    Tensile stress ≤ 85 N

     

    Electrical characteristics at 20 °C:

    Parameter
    Unit
    Value

    Capacitance
    pF/m
    ≤ 56

    Direct current resistance
    Оhm/km
    ≤ 85

    Insulation resistance
    GOhm/km
    ≥ 5

    Resistance unbalance
    %
    2

    Signal propagation velocity
    s
    0,68

    Propagation delay
    ns/100 m
    ≤ 534+36/√f

    Delay shift on the frequency 100 MHz
    ns/100 m
    ≤ 30

    Characteristic impedance in the frequency range of:

    1-100 MHz

    100-250 MHz
     

    Ohm
     

    100±15

    100±22

    Test voltage between cores, (DC, 2 s)
    kV
    2,5

     

    Frequency, MHz
    1
    4
    10
    16
    20
    31,25

    Attenuation, dB, max
    2,1
    3,8
    6
    7,6
    8,5
    10,8

    NEXT, dB, min
    75,3
    66,3
    60,3
    57,3
    55,8
    52,8

    PS NEXT, dB, min
    72,3
    63,3
    57,3
    54,3
    52,8
    49,8

    ELFEXT, dB, min
    68
    56
    48
    44
    42
    38

    PS ELFEXT, dB, min
    65
    53
    45
    41
    39
    35

    RL, dB, min
    20,0
    23,0
    25,0
    25,0
    25,0
    23,6

    Frequency, MHz
    62,5
    100
    250

    Attenuation, dB, max
    15,5
    19,9
    33

    NEXT, dB, min
    48,3
    45,3
    39,3

    PS NEXT, dB, min
    45,3
    42,3
    36,3

    ELFEXT, dB, min
    32
    28
    20

    PS ELFEXT, dB, min
    29
    25
    17

    RL, dB, min
    21,5
    20,1
    17,3

    IEC 61156-5, values lower than 4 MHz are given for information only

    LAN Cable CAT6 F/UTP 4x2x23 AWG Outdoor

  • Application

    • PBX, 11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Token Ring 16/100 Mbit/s
    • Fast Ethernet (100BASE-TX), Gigabit Ethernet (1000BASE-T), 2,5 Gbit/s Ethernet (2.5GBASE-T) and 5 Gbit/s (5GBASE-T)
    • PoE, PoE+, PoE++

    Installation and Operation Conditions

    To provide support for aerial outdoor applications in conditions of height- ened electromagnetic impacts. Operated on frequencies up to 250 MHz

    Compliance with the requirements

    Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568.2-D

    Cable: IEC 61156-5, EN 50288-5-1, ANSI/TIA-568.2-D

    CPR euroclass: Fca

    LAN Cable CAT6 F/UTP 4x2x23 AWG Outdoor Aerial

  • Application:

    PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s,

    100VG-AnyLAN, Token Ring 16/100 Mbit/s, Fast Ethernet (100BASE- TX), 1000BASE-T, 2.5GBASE-T, 5GBASE-T, PoE, PoE+, PoE++

    Installation and Operation conditions:

    For stationary installation inside buildings, stations, structures and equipment. Op- erated on frequencies up to 250 MHz

    Standads:

    Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568.2-D

    Cable: IEC 61156-5, EN 50288-6-1, ANSI/TIA-568.2-D

    Fire safety:

    • Flame propagation: EN 60332-1-2

    CPR class: Eca

    Mechanical characteristics:

    Temperature range:

    • During installation -10 °C … +60 °C
    • After installation -20 °C … +60 °C

     

    Bending radius:

    • During installation ≥ 8 cable diameters
    • After installation ≥ 4 cable diameters

     

    Tensile stress ≤ 85 N

     

    Electrical characteristics at 20 °C:

    Parameter
    Unit
    Value

    Capacitance
    pF/m
    ≤ 56

    Resistance for conductor Ø, mm:

    ·     0,54
    Оhm/km
    ≤ 82

    Insulation resistance
    GOhm*km
    ≥ 5

    Resistance unbalance
    %
    1

    Velocity of propagation (NVP)
    %
    70

    Propagation delay
    ns/100 m
    ≤ 534+36/√f

    Delay skew
    ns/100 m
    ≤ 20

    Characteristic impedance in the frequency range of:

    ·     1-100 MHz

    ·     101-250 MHz
     

    Ohm
     

    100±15

    100±22

    Test voltage between cores, (DC, 2 s)
    kV
    2,5

     

    Frequency, MHz
    1
    4
    10
    16
    20
    31,25

    Attenuation, dB, max
    2,1
    3,8
    6
    7,6
    8,5
    10,8

    NEXT, dB, min
    75,3
    66,3
    60,3
    57,3
    55,8
    52,8

    PS NEXT, dB, min
    72,3
    63,3
    57,3
    54,3
    52,8
    49,8

    ELFEXT, dB, min
    68
    56
    48
    44
    42
    38

    PS ELFEXT, dB, min
    65
    53
    45
    41
    39
    35

    RL, dB, min
    20,0
    23,0
    25,0
    25,0
    25,0
    23,6

    Frequency, MHz
    62,5
    100
    250

    Attenuation, dB, max
    15,5
    19,9
    33

    NEXT, dB, min
    48,3
    45,3
    39,3

    PS NEXT, dB, min
    45,3
    42,3
    36,3

    ELFEXT, dB, min
    32
    28
    20

    PS ELFEXT, dB, min
    29
    25
    17

    RL, dB, min
    21,5
    20,1
    17,3

    IEC 61156-5, values lower than 4 MHz are given for information only

    LAN Cable CAT6 UTP 4x2x23 AWG Indoor

    • For 22-26AWG stranded and solid wire
    • Meet TIA/ EIA-568A and TIA/ EIA-568B CAT5E/ CAT6 Requirements
    • Labels for T568A and T568B wiring standards
    • Gold-plated contacts
    • IDC modules fit Krone or 110 impact tools
    • Impact resistant construction

    LAN Coupler Inline

  • Feature:

    • Panel clip for easy installation
    • High temperature stability
    • High precision alignment
    • Good interchangeability
    • Low insertion loss
    • Good repeatability
    • Good durability
    • Compact design

    Application:

    • Optical Fiber Communication System
    • Telecommunication Network
    • Local Area Networks(LAN)
    • Data Processing Networks
    • Engineering ReLCue
    • Test Equipment
    • Fiber CATV
    • FTTH
    • Optical Distribution Frame
    • Docking Connector

    LC UPC SM Adapter DX

  • Feature:

    • Panel clip for easy installation
    • High temperature stability
    • High precision alignment
    • Good interchangeability
    • Low insertion loss
    • Good repeatability
    • Good durability
    • Compact design

    Application:

    • Optical Fiber Communication System
    • Telecommunication Network
    • Local Area Networks(LAN)
    • Data Processing Networks
    • Engineering ReLCue
    • Test Equipment
    • Fiber CATV
    • FTTH
    • Optical Distribution Frame
    • Docking Connector

    LC UPC SM Adapter SX

  • Application

    Designed for connection home acoustics (speakers, music centers, home cinemas), lengthening speaker cords.

    Cable design

    1. Conductor: copper wire (conductor structure complies with VDE 0295 class 6)
    2. Sheath: ion stable PVC (transparent with a longitudinal black stripe).

    Installation and operation conditions

    Temp Rating:

    • Installation Temp Rating: -10 °C … +50 °C;
    • Operating Temp Range: -20 °C … +70 °C.

    Min Bend Radius: 5 cable diameters.

    Main technical and mechanical characteristics

    Cable brand                                          Resistance, Ohm/km     Capacitance, pF/m     Inductance, mH/k

    Loudspeaker Cable 2*0,75 Hi-Fi
    23,5                               60                                     0,61

     

    Nomenclature and mass-dimensional characteristics

    Cable brand                                                     Outside diameter, mm                            Weight, kg/km

    Loudspeaker Cable 2*0,75 Hi-Fi
    2,5х5,4
    27,1

    Loudspeaker cable 2×0,75 mm²

  • Application

    Designed for connection home acoustics (speakers, music centers, home cinemas), lengthening speaker cords.

    Cable design

    1. Conductor: copper wire (conductor structure complies with VDE 0295 class 6)
    2. Sheath: ion stable PVC (transparent with a longitudinal black stripe).

    Installation and operation conditions

    Temp Rating:

    • Installation Temp Rating: -10 °C … +50 °C;
    • Operating Temp Range: -20 °C … +70 °C.

    Min Bend Radius: 5 cable diameters.

    Main technical and mechanical characteristics

    Cable brand                                          Resistance, Ohm/km     Capacitance, pF/m     Inductance, mH/k

    Loudspeaker Cable 2*0,75 Hi-Fi
    12,5                              67                                     0,54

     

    Nomenclature and mass-dimensional characteristics

    Cable brand                                                     Outside diameter, mm                            Weight, kg/km

    Loudspeaker Cable 2*0,75 Hi-Fi
    3,5х7,4
    54,7

    Loudspeaker cable 2×1,5 mm²

  • Features:

    1. Automatically adapt to 10/100/1000Mbps environment to facilitate network upgrade
    2. Built-in high-efficiency switching core to realize flow control and reduce broadcast packets
    3. Supports full-duplex and half-duplex transmission modes, and can automatically negotiate
    4. Supports automatic crossover of twisted pair ports, which is convenient for system debugging and installation
    5. Support FX half/full duplex
    6. Support storage and forwarding or 1000Mbps direct transmission mode
    7. Support low-latency transmission
    8. Support 1600byte long data packet transmission
    9. Support STP spanning tree to form a redundant network
    10. It supports multiple fiber port options of dual fiber multimode, dual fiber single mode and single fiber single mode, which expands the needs of users

    Optic Converter SM 1 Pair A B 1 GBPS 40KM

  • Features:

    1. Automatically adapt to 10/100/1000Mbps environment to facilitate network upgrade
    2. Built-in high-efficiency switching core to realize flow control and reduce broadcast packets
    3. Supports full-duplex and half-duplex transmission modes, and can automatically negotiate
    4. Supports automatic crossover of twisted pair ports, which is convenient for system debugging and installation
    5. Support FX half/full duplex
    6. Support storage and forwarding or 1000Mbps direct transmission mode
    7. Support low-latency transmission
    8. Support 1600byte long data packet transmission
    9. Support STP spanning tree to form a redundant network
    10. It supports multiple fiber port options of dual fiber multimode, dual fiber single mode and single fiber single mode, which expands the needs of users

    Optic Converter SM 1 Pair A B 1 GBPS 20KM

    1. Automatically adapt to 10/100Mbps environment to facilitate network upgrade
    2. Built-in high-efficiency switching core to realize flow control and reduce broadcast packets
    3. Supports full-duplex and half-duplex transmission modes, and can automatically negotiate
    4. Supports automatic crossover of twisted pair ports, which is convenient for system debugging and installation
    5. Support FX half/full duplex
    6. Support storage and forwarding or 100Mbps direct transmission mode
    7. Support low-latency transmission
    8. Support STP spanning tree to form a redundant network
    9. It supports multiple fiber port options of dual fiber multimode, dual fiber single mode and single fiber single mode, which expands the needs of users

    Optic Converter SM 1 Pair A B 100 MBPS 25KM

  • The optical fiber patch cords are suitable for data communication, telecommunication applications.
    Our patch cords are with standard optical specifications, precise length tolerances.
    All assemblies are 100% inspected for optical characteristics and fiber end face finish.
    The terminated connectors in assemblies are designed to and are compatible with industry standards

     

    Features:

    • Adopts high precision ceramic ferrule with good concentricity
    • Compact & strong crimping offers exceptional tensile strength in cable assemblies
    • 100% inspected for optical characteristics & fiber endface finish
    • Low insertion loss & return loss, clean and LCratch-free end faces
    • Good performance endurance under changing circumstances

    Optic Patch Cord LC-LC SM 9/125 DX

  • The optical fiber patch cords are suitable for data communication, telecommunication applications. Our patch cords are with standard optical specifications, precise length tolerances.
    All assemblies are 100% inspected for optical characteristics and fiber end face finish.
    The terminated connectors in assemblies are designed to and are compatible with industry standards

     

    Features:

    • Adopts high precision ceramic ferrule with good concentricity
    • Compact & strong crimping offers exceptional tensile strength in cable assemblies
    • 100% inspected for optical characteristics & fiber endface finish
    • Low insertion loss & return loss, clean and scratch-free end faces
    • Good performance endurance under changing circumstances

    Optic Patch Cord SC-LC APC SM 9/125 DX

  • The optical fiber patch cords are suitable for data communication, telecommunication applications. Our patch cords are with standard optical specifications, precise length tolerances.
    All assemblies are 100% inspected for optical characteristics and fiber end face finish.
    The terminated connectors in assemblies are designed to and are compatible with industry standards

     

    Features:

    • Adopts high precision ceramic ferrule with good concentricity
    • Compact & strong crimping offers exceptional tensile strength in cable assemblies
    • 100% inspected for optical characteristics & fiber endface finish
    • Low insertion loss & return loss, clean and scratch-free end faces
    • Good performance endurance under changing circumstances

    Optic Patch Cord SC-LC MM 50/125 DX OM3

  • The optical fiber patch cords are suitable for data communication, telecommunication applications. Our patch cords are with standard optical specifications, precise length tolerances.
    All assemblies are 100% inspected for optical characteristics and fiber end face finish.
    The terminated connectors in assemblies are designed to and are compatible with industry standards

     

    Features:

    • Adopts high precision ceramic ferrule with good concentricity
    • Compact & strong crimping offers exceptional tensile strength in cable assemblies
    • 100% inspected for optical characteristics & fiber endface finish
    • Low insertion loss & return loss, clean and scratch-free end faces
    • Good performance endurance under changing circumstances

    Optic Patch Cord SC-LC SM 9/125 DX