Line Interactive

  • Apex03-1K-3 LED UPS

     Input:

    • Capacity: 1000 VA / 600 W
    • Voltage: 110/120 VAC or 220/230/240 VAC
    • Voltage range: 81-145 Vac / 162-290 VAC
    • Frequency range: 60-50 Hz (auto sensing)Output:
    • Output voltage: 110/120 or 220/230/240 VAC
    • AC voltage regulation (Batt. Mode): ± 10%
    • Frequency range (Batt. Mode): 50 Hz or 60 Hz ± 1 Hz
    • Transfer time: Typical 2-3 ms
    • Waveform (Batt. Mode): Simulated sinewave

      Battery:
    • Battery type & number: 12 V/7 Ah x 2
    • Typical recharge time: 4-6 hours recover to 90% capacity

      Protection:
    • Full protection: overload, discharge and overcharge protection

      Indicators:
    • AC mode: Green lighting
    • Battery mode: Green lighting
    • Fault: N/A

      Alarm:
    • Battery mode: Sounding every 10 seconds
    • Low battery Sounding every second
    • Overload: Sounding every 0.5 second
    • Fault: Continuously sounding

      Physical:
    • Dimension: D x W x H (mm): 320 x 130 x 182
    • Net weight (kgs): 8.2

      Environment:

    • Humidity: 0-90 % RH @ 0-40°C (non-condensing)
    • Noise leverl: less than 40 dB
  • Apex14-2K-3LED UPS

    Input:

    • Capacity: 2000 VA / 1200 W
    • Voltage: 110/120 VAC or 220/230/240 VAC
    • Voltage range: 81-145 Vac / 162-290 VAC
    • Frequency range: 60-50 Hz (auto sensing)

      Output:
    • Output voltage: 110/120 or 220/230/240 VAC
    • AC voltage regulation (Batt. Mode): ± 10%
    • Frequency range (Batt. Mode): 50 Hz or 60 Hz ± 1 Hz
    • Transfer time: Typical 2-3 ms
    • Waveform (Batt. Mode): Simulated sinewave

      Battery:
    • Battery type & number: 12 V/9 Ah x 2
    • Typical recharge time: 4-6 hours recover to 90% capacity

      Protection:
    • Full protection: overload, discharge and overcharge protection

      Indicators:
    • AC mode: Green lighting
    • Battery mode: Yellow flashing
    • Fault: Red lighting

      Alarm:
    • Battery mode: Sounding every 10 seconds
    • Low battery Sounding every second
    • Overload: Sounding every 0.5 second
    • Fault: Continuously sounding

      Physical:
    • Dimension: D x W x H (mm): 320 x 130 x 182
    • Net weight (kgs): 10.6

      Environment:
    • Humidity: 0-90 % RH @ 0-40°C (non-condensing)
    • Noise leverl: less than 40 dB
  • Winner Pro Plus 2k UPS

          Input:

    • Capacity: 2000 VA / 1800 W
    • Nominal voltage: 110/115/120/127 VAC or 208/220/230/240 VAC
    • Voltage range: 60-145 VAC or 120-300 VAC at 50% load / 90-145 VAC or 180-300 VAC at 100% load
    • Frequency range: 60-70 Hz
    • Power factor: ≥ 0.99 @ nominal voltage (100% load)
      Output:
    • Output voltage: 110/115/120/127 VAC
    • Voltage regulation : ± 1%
    • Frequency range: 47-53 Hz or 57-63 Hz
    • Frequency range(Batt. Mode): 50 Hz or 60 Hz ± 0.5
    • Current crest ratio: 3:1
    • Harmonic distortion (Linear load): ≤ 3% THD
    • Harmonic distortion (non-linear load): ≤ 6% THD
    • Transfer time: 0 ms
    • Waveform (Batt. Mode): Pure sinewave
      Efficiency:
    • AC mode: 89%
    • Battery mode: 87%
      Battery:
    • Battery type & number: 12 V/9 Ah
    • Numbers: 2/3
    • Typical recharge time: 4 hours recover to 90% capacity
    • Charging current: 1.0A/2.0A (adjustable)
      Indicators:
    • LCD Panel: UPS status, load level, battery level, input/output voltage, discharge timer, fault conditions
      Alarm:
    • Battery mode: Sounding every 4 seconds
    • Low battery Sounding every second
    • Overload: Sounding every 0.5 second
    • Fault: Continuously sounding
      Physical:
    • Dimension: D x W x H (mm)(UPS unit): 421 x 190 x 318(3U)
    • Dimension: D x W x H (mm)(battery pack): 580 x 438 x 133(3U)
    • Net weight (kgs)(UPS unit): 26.2
    • Net weight (kgs)(battery pack): 6.8
      Environment:
    • Humidity: 20-90 % RH @ 0-40°C (Non-condensing)
    • Noise level: less than 50 dB
      Management:
    • Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
    • Optional SNMP: Power management from SNMP manager and web browser

     

  • Winner Pro Plus-Rack 3K-ZR6-R UPS

    Input:

    • Capacity: 3000 VA / 2700 W
    • Nominal voltage: 110/115/120/127VAC or 208/220/230/240VAC
    • Voltage range:  60-145 VAC  or 120-300 VAC at 50% load, 90-145 VAC or 180-300 VAC at 100% load
    • Frequency range: 40Hz  ~ 70 Hz
    • Power factor: ≥ 0.99 @ nominal voltage (100% load)
      Output:
    • Output voltage: 110/115/120/127VAC or 208/220/230/240VAC   
    • Voltage regulation : ± 1%
    • Frequency range: 47~ 53 Hz or 57 ~ 63 Hz
    • Frequency range(Batt. Mode): 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
    • Current crest ratio: 3:1
    • Harmonic distortion (Linear load): ≤ 3% THD
    • Harmonic distortion (non-linear load): ≤ 6% THD
    • Transfer time: 0 ms
    • Waveform (Batt. Mode): Pure sinewave
      Efficiency:
    • AC mode: 90% 
    • Battery mode: 88%
      Battery:
    • Battery type & number: 12 V/9 Ah 
    • Numbers: 6
    • Typical recharge time: 4 hours recover to 90% capacity
    • Charging current: 1.0A
      Physical:
    • Dimension: D x W x H (mm)(UPS unit): 630 x 438 x 88
    • Dimension: D x W x H (mm)(battery pack): 630 x 438 x 88
    • Net weight (kgs)(UPS unit): 29.3
    • Net weight (kgs)(battery pack): 14.2
      Environment:
    • Humidity: 20-90 % RH @ 0- 40°C (non-condensing)
    • Noise level: Less than 50dBA @ 1 Meter
      Management:
    • Smart RS-232 / USB: Supports Windows®️ 2000/2003/XP/Vista/2008/Windows®️7/8, Linux, MAC
    • Optional SNMP: Power management from SNMP manager and web browser