Line Interactive

  • No thumb

    APEX 1500VA – 3 LED UPS

    MODEL
    Apex 1.5K

    CAPACITY
    1500 VA / 900 W

    INPUT

    Voltage
    110/120 VAC or 220/230/240 VAC

    Voltage Range
    81-145 VAC / 162-290 VAC

    Frequency Range
    60/50 Hz (Auto sensing)

    OUTPUT

    Output Voltage
    110/120 VAC or 220/230/240 VAC

    AC Voltage Regulation (Batt. Mode)
    ± 10%

    Frequency Range (Batt. Mode)
    50 Hz or 60 Hz ± 1 Hz

    Transfer Time
    Typical 2-6 ms

    Waveform (Batt. Mode)
    Simulated Sinewave

    BATTERY

    Battery Type & Number
    12 V/9 Ah x 2

    Typical Recharge Time
    4-6 hours recover to 90% capacity

    PROTECTION

    Full Protection
    Overload, discharge, and overcharge protection

    INDICATORS

    LCD Model
    Input voltage, output voltage, battery capacity, load level and UPS status

    LED Model
    AC Mode
    Green lighting

    Battery Mode
    Yellow flashing

    Fault
    Red lighting

    ALARM

    Battery Mode
    Sounding every 10 seconds

    Low Battery
    Sounding every second

    Overload
    Sounding every 0.5 second

    Fault
    Continuously sounding

    PHYSICAL

    LED Model
    Dimension, D x W x H (mm)
    320 x 130 x 182

    Net Weight (kgs)
    10.6

    LCD Model
    Dimension, D x W x H (mm)
    320 x 130 x 182

    Net Weight (kgs)
    10.6

    ENVIRONMENT

    Humidity
    0-90 % RH @ 0- 40°C (Non-condensing)

    Noise Level
    Less than 40dB

  • No thumb

    APEX 800VA -3 LED UPS

    MODEL
    Apex 800

    CAPACITY
    800 VA / 480 W

    INPUT

    Voltage
    110/120 VAC or 220/230/240 VAC

    Voltage Range
    81-145 VAC / 162-290 VAC

    Frequency Range
    60/50 Hz (Auto sensing)

    OUTPUT

    Output Voltage
    110/120 VAC or 220/230/240 VAC

    AC Voltage Regulation (Batt. Mode)
    ± 10%

    Frequency Range (Batt. Mode)
    50 Hz or 60 Hz ± 1 Hz

    Transfer Time
    Typical 2-6 ms

    Waveform (Batt. Mode)
    Simulated Sinewave

    BATTERY

    Battery Type & Number
    12 V/9 Ah x 1

    Typical Recharge Time
    4 hours recover to 90% capacity

    PROTECTION

    Full Protection
    Overload, discharge, and overcharge protection

    INDICATORS

    LCD Model
    Input voltage, output voltage, battery capacity, load level and UPS status

    LED Model
    AC Mode
    Green lighting

    Battery Mode
    Green flashing

    Fault
    N/A

    ALARM

    Battery Mode
    Sounding every 10 seconds

    Low Battery
    Sounding every second

    Overload
    Sounding every 0.5 second

    Fault
    Continuously sounding

    PHYSICAL

    LED Model
    Dimension, D x W x H (mm)
    279 x 101 x 142

    Net Weight (kgs)
    4.9

    LCD Model
    Dimension, D x W x H (mm)
    300 x 101 x 142

    Net Weight (kgs)
    5.0

    ENVIRONMENT

    Humidity
    0-90 % RH @ 0- 40°C (Non-condensing)

    Noise Level
    Less than 40dB

  • No thumb

    APEX 600VA-3 LED UPS

    MODEL
    Apex 600

    CAPACITY
    600 VA / 360 W

    INPUT

    Voltage
    110/120 VAC or 220/230/240 VAC

    Voltage Range
    81-145 VAC / 162-290 VAC

    Frequency Range
    60/50 Hz (Auto sensing)

    OUTPUT

    Output Voltage
    110/120 VAC or 220/230/240 VAC

    AC Voltage Regulation (Batt. Mode)
    ± 10%

    Frequency Range (Batt. Mode)
    50 Hz or 60 Hz ± 1 Hz

    Transfer Time
    Typical 2-6 ms

    Waveform (Batt. Mode)
    Simulated Sinewave

    BATTERY

    Battery Type & Number
    12 V/7 Ah x 1

    Typical Recharge Time
    4 hours recover to 90% capacity

    PROTECTION

    Full Protection
    Overload, discharge, and overcharge protection

    INDICATORS

    LCD Model
    Input voltage, output voltage, battery capacity, load level and UPS status

    LED Model
    AC Mode
    Green lighting

    Battery Mode
    Green flashing

    Fault
    N/A

    ALARM

    Battery Mode
    Sounding every 10 seconds

    Low Battery
    Sounding every second

    Overload
    Sounding every 0.5 second

    Fault
    Continuously sounding

    PHYSICAL

    LED Model
    Dimension, D x W x H (mm)
    279 x 101 x 142

    Net Weight (kgs)
    4.2

    LCD Model
    Dimension, D x W x H (mm)
    300 x 101 x 142

    Net Weight (kgs)
    4.4

    ENVIRONMENT

    Humidity
    0-90 % RH @ 0- 40°C (Non-condensing)

    Noise Level
    Less than 40dB

  • Apex14-2K-3LED UPS

    Input:

    • Capacity: 2000 VA / 1200 W
    • Voltage: 110/120 VAC or 220/230/240 VAC
    • Voltage range: 81-145 Vac / 162-290 VAC
    • Frequency range: 60-50 Hz (auto sensing)

      Output:
    • Output voltage: 110/120 or 220/230/240 VAC
    • AC voltage regulation (Batt. Mode): ± 10%
    • Frequency range (Batt. Mode): 50 Hz or 60 Hz ± 1 Hz
    • Transfer time: Typical 2-3 ms
    • Waveform (Batt. Mode): Simulated sinewave

      Battery:
    • Battery type & number: 12 V/9 Ah x 2
    • Typical recharge time: 4-6 hours recover to 90% capacity

      Protection:
    • Full protection: overload, discharge and overcharge protection

      Indicators:
    • AC mode: Green lighting
    • Battery mode: Yellow flashing
    • Fault: Red lighting

      Alarm:
    • Battery mode: Sounding every 10 seconds
    • Low battery Sounding every second
    • Overload: Sounding every 0.5 second
    • Fault: Continuously sounding

      Physical:
    • Dimension: D x W x H (mm): 320 x 130 x 182
    • Net weight (kgs): 10.6

      Environment:
    • Humidity: 0-90 % RH @ 0-40°C (non-condensing)
    • Noise leverl: less than 40 dB
  • Apex03-1K-3 LED UPS

     Input:

    • Capacity: 1000 VA / 600 W
    • Voltage: 110/120 VAC or 220/230/240 VAC
    • Voltage range: 81-145 Vac / 162-290 VAC
    • Frequency range: 60-50 Hz (auto sensing)Output:
    • Output voltage: 110/120 or 220/230/240 VAC
    • AC voltage regulation (Batt. Mode): ± 10%
    • Frequency range (Batt. Mode): 50 Hz or 60 Hz ± 1 Hz
    • Transfer time: Typical 2-3 ms
    • Waveform (Batt. Mode): Simulated sinewave

      Battery:
    • Battery type & number: 12 V/7 Ah x 2
    • Typical recharge time: 4-6 hours recover to 90% capacity

      Protection:
    • Full protection: overload, discharge and overcharge protection

      Indicators:
    • AC mode: Green lighting
    • Battery mode: Green lighting
    • Fault: N/A

      Alarm:
    • Battery mode: Sounding every 10 seconds
    • Low battery Sounding every second
    • Overload: Sounding every 0.5 second
    • Fault: Continuously sounding

      Physical:
    • Dimension: D x W x H (mm): 320 x 130 x 182
    • Net weight (kgs): 8.2

      Environment:

    • Humidity: 0-90 % RH @ 0-40°C (non-condensing)
    • Noise leverl: less than 40 dB