-
DESIGN
- Conductor: soft copper Diameter: 0,51 mm (±0,005 mm)
- Insulation: PE . Conductor diameter: 1,03 mm
- Pair: two conductors twisted together. Color identification of pairs: white-blue / blue and white – orange / orange
- Core wrapping
- Copper tinned contact wire Ø 0,4 mm is applied between the sheath and shield.
- Core shield: aluminum polymer foil (metal inside)
- Sheath: PE, nominal cable diameter: 6,0 mm, color: black
APPLICATION
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s,
100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s,
Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, ATM LAN 1,2 Gbit/s
СOMPLIANCE WITH THE REQUIREMENTS
ISO/IEC 11801:2002, EN 50173-1:2002, ANSI/TIA/EIA-568-B.2-1-2002, IEC 61156-5:2002, TU U 31.3-05758730-020-2002
MECHANICAL CHARACTERISTICS
Тemperature range:
During installation -10 °C … +60 °C
After installation -50 °C … +60 °C
Bending radius:
During installation ≥ 8 cable diameters After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance
Оhm/km
≤ 100Insulation resistance
GOhm/km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,65Characteristic impedance in the frequency range of:
Ohm
100±15Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20Attenuation, dB, max
2,1
4,1
6,5
8,3
9,3NEXT, dB, min
65,3
56,2
50,3
47,2
45,7PS NEXT, dB, min
62,3
53,2
47,3
44,2
42,7ELFEXT, dB, min
64
51,9
44
39,9
37,9PS ELFEXT, dB, min
61
48,9
41
36,9
34,9RL, dB, min
20
23
25
25
25Frequency, MHz
31,25
62,5
100Attenuation, dB, max
11,7
17,0
22,0NEXT, dB, min
42,8
38,3
35,3PS NEXT, dB, min
39,8
35,3
32,3ELFEXT, dB, min
34,1
28
24PS ELFEXT, dB, min
31,1
25
21RL, dB, min
23,6
21,5
20,1IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT 5 F/UTP 2x2x24 AWG outdoor
-
APPLICATION
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T
СOMPLIANCE WITH THE REQUIREMENTS
Cable: IEC 61156-5 (cat.5e)
Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
Fire safety: IEC 60332-1, CPR class Eca
MECHANICAL CHARACTERISTICS
Тemperature range:
· During installation -10 °C … +60 °C
· After installation -20 °C … +60 °C
Bending radius:· During installation ≥ 8 cable diameters
· After installation ≥ 4 cable diameters
Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance for
conductors with Ø:
0,51 mm
0,48 mm
0,46 mm
0,44 mm
Оhm/km
≤ 92
≤ 103
≤ 112
≤ 123
Insulation resistance
GOhm*km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,69Characteristic impedance in the
frequency range of: 1-100 MHz
Ohm
100±15Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20Attenuation, dB, max; for max. cable lengths with conductor Ø:
2,1
4,1
6,5
8,3
9,30,51 mm = 104 m
0,48 mm = 92 m
0,46 mm = 84 m
0,44 mm = 77 m
NEXT, dB, min
65,3
56,3
50,3
47,2
45,8PS NEXT, dB, min
62,3
53,3
47,3
44,2
42,8ELFEXT, dB, min
64
52
44
40
38PS ELFEXT, dB, min
61
49
41
37
35RL, dB, min
20,0
23,0
25,0
25,0
25,0Frequency, MHz
31,25
62,5
100Attenuation, dB, max; for max. cable lengths with conductor Ø:
11,7
17,0
22,00,51 mm = 104 m
0,48 mm = 92 m
0,46 mm = 84 m
0,44 mm = 77 m
NEXT, dB, min
42,9
38,4
35,3PS NEXT, dB, min
39,9
35,4
32,3ELFEXT, dB, min
34
28,1
24PS ELFEXT, dB, min
31
25,1
21RL, dB, min
23,6
21,5
20,1IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT 5 SF/UTP 4x2x23 AWG
-
Application
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s
Installation and Operation Conditions
For outdoor installation in telephone ducts, collectors, mines, on the walls of buildings in conditions of heightened electro-magnetic impacts.
Operated on frequencies up to 250 MHzCompliance with the requirements
Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568-C.2
Cable: IEC 61156-2
Mechanical Characteristics
Temperature range: During installation -10 °C … +60 °C
After installation -20 °C … +60 °C
Bending radius: During installation ≥ 8 cable diameters
After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance
Оhm/km
≤ 95Insulation resistance
GOhm/km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,68Propagation delay
ns/100 m
≤ 534+36/√fDelay shift on the frequency 100 MHz
ns/100 m
≤ 30Characteristic impedance in the frequency range of:
1-100 MHz
Ohm
100±15
Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20Attenuation, dB, max:
2,1
4,1
6,5
8,3
9,3NEXT, dB, min
65,3
56,3
50,3
47,2
45,8ELFEXT, dB, min
64
52
44
40
38RL, dB, min
20,0
23,0
25,0
25,0
25,0Frequency, MHz
31,25
62,5
100Attenuation, dB, max:
11,7
17,0
22,0NEXT, dB, min
42,9
38,4
35,3ELFEXT, dB, min
34
28
24RL, dB, min
23,3
20,7
19,0IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT 5 U/UTP 2x2x24 AWG indoor
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T (up to 55 meters)
DESIGN:
- Conductor: solid annealed copper
- Insulation: solid PE
- Pair: two conductors twisted together
- Core wrapping
- Copper tinned contact wire Ø 0,4 mm
- Core shield: aluminum polymer foil (metal outside)
- Jacket: PVC, color RAL 7035
СOMPLIANCE WITH THE REQUIREMENTS:
- Cable: IEC 61156-5 (cat.5e)
- Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
- Fire safety: IEC 60332-1, CPR class EcaMECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius:
– During installation ≥ 8 cable diameters
– After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors: Оhm/km ≤ 95
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 5E F/UTP 4x2x24 AWG Outdoor Cable
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T (up to 55 meters)
DESIGN:
- Conductor: solid annealed copper
- Insulation: LSZH
- Pair: two conductors twisted together
- Core wrapping
- Copper tinned contact wire Ø 0,4 mm
- Core shield: aluminum polymer foil (metal outside)
- Jacket: PVC, LSZH, LSFRZH
- СOMPLIANCE WITH THE REQUIREMENTS:
- Cable: IEC 61156-5 (cat.5e)
- Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
- Fire safety: IEC 60332-1, CPR class EcaMECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius:
– During installation ≥ 8 cable diameters
– After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors: Оhm/km ≤ 95
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 5E LSZH F/UTP 4x2x24 AWG Indoor Cable
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T (up to 55 meters)
DESIGN:
- Conductor: solid annealed copper
- Insulation: solid PE
- Pair: two conductors twisted together
- Core wrapping
- Jacket: PVC, color RAL 7035
- СOMPLIANCE WITH THE REQUIREMENTS:
- Cable: IEC 61156-5 (cat.5e)
- Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
- Fire safety: IEC 60332-1, CPR class Eca
MECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius:
– During installation ≥ 8 cable diameters
– After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors(-0.51 mm; -0.50mm): Оhm/km ≤ 92-95
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 5E U/UTP 4x2x24 AWG Indoor Cable
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T (up to 55 meters)
DESIGN:
- Conductor: solid annealed copper
- Insulation: PE
- Pair: two conductors twisted together:
– Pair 1: white-blue / blue
– Pair 2: white-orange / orange
– Pair 3: white-green / green
– Pair 4: white – brown / brown - Cross-web (PE or LSFRZH)
- Core wrapping
- Core shield: aluminum polymer foil (metal outside)
- Copper tinned contact wire Ø 0,4 mm
- Jacket: PVC, LSZH, LSFRZH
- MECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius: ≥ 10 cable diameters
- Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors(0,54 mm; 0,57 mm): Оhm/km ≤ 83-88
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 6 F/UTP 4x2x23 AWG Indoor Cable
-
APPLICATION
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155
Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, 10 Gigabit Ethernet (10GBASE-T*), ATM LAN 1,2 Gbit/s
INSTALLATION AND OPERATION CONDITIONS
For stationary installation inside buildings, stations, structures and equipment in conditions of heightened electromagnetic impacts. Operated on frequencies up to 250 MHz.
СOMPLIANCE WITH THE REQUIREMENTS
System: ISO/IEC 11801, EN 50173-1, ANSI/TIA 568-С.2 Cable: IEC 61156-5
Fire safety: IEC 60332-1, IEC 61034-1, IEC 60754-2
CPR class: Eca
MECHANICAL CHARACTERISTICS
Тemperature range:
During installation -10 °C … +60 °C / After installation -20 °C … +60 °C
Bending radius:
During installation ≥ 8 cable diameters / After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance
Оhm/km
≤ 85Insulation resistance
GOhm/km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,68Propagation delay
ns/100 m
≤ 534+36/√fDelay shift on the frequency 100 MHz
ns/100 m
≤ 30Characteristic impedance in the frequency range of: 1-100 MHz
100-250 MHz
Ohm
100±15
100±22
Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20
31,25Attenuation, dB, max
2,1
3,8
6
7,6
8,5
10,8NEXT, dB, min
75,3
66,3
60,3
57,3
55,8
52,8PS NEXT, dB, min
72,3
63,3
57,3
54,3
52,8
49,8ELFEXT, dB, min
68
56
48
44
42
38PS ELFEXT, dB, min
65
53
45
41
39
35RL, dB, min
20,0
23,0
25,0
25,0
25,0
23,6Frequency, MHz
62,5
100
125
200
250Attenuation, dB, max
15,5
19,9
22,5
29,1
33NEXT, dB, min
48,3
45,3
43,8
40,8
39,3PS NEXT, dB, min
45,3
42,3
40,8
37,8
36,3ELFEXT, dB, min
32
28
26
22
20PS ELFEXT, dB, min
29
25
23
19
17RL, dB, min
21,5
20,1
19,4
18,0
17,3IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT 6 F/UTP LSZH 4x2x23 AWG
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T
- 10GBASE-T
DESIGN:
- Conductor: soft copper wire
- Insulation: PE
- Pair: two conductors twisted together:
– Pair 1: white-blue / blue
– Pair 2: white-orange / orange
– Pair 3: white-green / green
– Pair 4: white – brown / brown - Cross-web (PE or LSFRZH)
- Core wrapping
- Core shield1: aluminum polymer foil (metal outside)
- Core shield 2: tined copper braid
- Sheath: UV-stabilized PE
- MECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius: ≥ 10 cable diameters
- Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors(0,54 mm; 0,57 mm): Оhm/km ≤ 83-88
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 6 SF/UTP 4x2x23 AWG Indoor Cable
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Token Ring 16/100 Mbit/s
- Fast Ethernet (100BASE-TX)
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T
- PoE
- PoE+
- 4PPoE
DESIGN:
- Conductor: solid annealed copper
- Insulation: PE
- Pair: two conductors twisted:
- Cross-web: HDPE, 2,6×2,6 mm
- Jacket: LS0H, nominal thickness 0,5 mm; PVC, nominal thickness 0,5 mm
- STANDARDS:
- Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568.2-D
- Cable: IEC 61156-5, EN 50288-6-1
- Fire safety:LS0H jacket: EN 60332-1-2
- CPR class: Eca
- MECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius:- During installation ≥ 8 cable diameters- After installation ≥ 4 cable diameters
- Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors TPG(0,52; 0,54 mm; 0,57 mm): Оhm/km ≤ 75-82-87
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 6 U/UTP LSZH 4x2x23 AWG Indoor Cable
-
Application:
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, ATM LAN 1,2 Gbit/s
Сompliance with the requirements:
Cable: IEC 61156-5 (cat.5e)
Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
Fire safety: IEC 60332-1, CPR class Eca
Mechanical characteristics:
Тemperature range:
- During installation -10 °C … +60 °C
- After installation -20 °C … +60 °C
Bending radius:
- During installation ≥ 8 cable diameters
- After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C:
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance for
Оhm/kmconductors with Ø:
0,51 mm
≤ 920,48 mm
≤ 1030,46 mm
≤ 1120,44 mm
≤ 123Insulation resistance
GOhm*km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,69Characteristic impedance in the
Ohm
100±15frequency range of: 1-100 MHz
Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20
31,25Attenuation, dB, max; for max. cable lengths with conductor Ø:
2,1
4,1
6,5
8,3
9,3
11,70,51 mm = 104 m
0,48 mm = 92 m
0,46 mm = 84 m
0,44 mm = 77 m
NEXT, dB, min
65,3
56,3
50,3
47,2
45,8
42,9PS NEXT, dB, min
62,3
53,3
47,3
44,2
42,8
39,9ELFEXT, dB, min
64
52
44
40
38
34PS ELFEXT, dB, min
61
49
41
37
35
31RL, dB, min
20,0
23,0
25,0
25,0
25,0
23,3Frequency, MHz
62,5
100Attenuation, dB, max; for max. cable lengths with conductor Ø:
17,0
22,00,51 mm = 104 m
0,48 mm = 92 m
0,46 mm = 84 m
0,44 mm = 77 m
NEXT, dB, min
38,4
35,3PS NEXT, dB, min
35,4
32,3ELFEXT, dB, min
28
24PS ELFEXT, dB, min
25
21RL, dB, min
20,7
19,0IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT5 F/UTP 4x2x24 AWG Indoor
-
Application:
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T, 10GBASE-T (under 55 m)
Installation and Operation conditions:
For outdoor installation in telephone ducts, collectors, mines, on the walls of buildings in conditions of heightened electro-magnetic impacts. Operated on frequencies up to 250 MHz
Compliance with the requirements:
Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568-C.2
Cable: IEC 61156-5, EN 50288-5-1
Mechanical characteristics:
Temperature range:
- During installation -10 °C … +60 °C
- After installation -50 °C … +60 °C
Bending radius:
- During installation ≥ 8 cable diameters
- After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
Electrical characteristics at 20 °C:
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance
Оhm/km
≤ 85Insulation resistance
GOhm/km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,68Propagation delay
ns/100 m
≤ 534+36/√fDelay shift on the frequency 100 MHz
ns/100 m
≤ 30Characteristic impedance in the frequency range of:
1-100 MHz
100-250 MHz
Ohm
100±15
100±22
Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20
31,25Attenuation, dB, max
2,1
3,8
6
7,6
8,5
10,8NEXT, dB, min
75,3
66,3
60,3
57,3
55,8
52,8PS NEXT, dB, min
72,3
63,3
57,3
54,3
52,8
49,8ELFEXT, dB, min
68
56
48
44
42
38PS ELFEXT, dB, min
65
53
45
41
39
35RL, dB, min
20,0
23,0
25,0
25,0
25,0
23,6Frequency, MHz
62,5
100
250Attenuation, dB, max
15,5
19,9
33NEXT, dB, min
48,3
45,3
39,3PS NEXT, dB, min
45,3
42,3
36,3ELFEXT, dB, min
32
28
20PS ELFEXT, dB, min
29
25
17RL, dB, min
21,5
20,1
17,3IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT6 F/UTP 4x2x23 AWG Outdoor
-
Application:
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s,
100VG-AnyLAN, Token Ring 16/100 Mbit/s, Fast Ethernet (100BASE- TX), 1000BASE-T, 2.5GBASE-T, 5GBASE-T, PoE, PoE+, PoE++
Installation and Operation conditions:
For stationary installation inside buildings, stations, structures and equipment. Op- erated on frequencies up to 250 MHz
Standads:
Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568.2-D
Cable: IEC 61156-5, EN 50288-6-1, ANSI/TIA-568.2-D
Fire safety:
- Flame propagation: EN 60332-1-2
CPR class: Eca
Mechanical characteristics:
Temperature range:
- During installation -10 °C … +60 °C
- After installation -20 °C … +60 °C
Bending radius:
- During installation ≥ 8 cable diameters
- After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
Electrical characteristics at 20 °C:
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Resistance for conductor Ø, mm:
· 0,54
Оhm/km
≤ 82Insulation resistance
GOhm*km
≥ 5Resistance unbalance
%
1Velocity of propagation (NVP)
%
70Propagation delay
ns/100 m
≤ 534+36/√fDelay skew
ns/100 m
≤ 20Characteristic impedance in the frequency range of:
· 1-100 MHz
· 101-250 MHz
Ohm
100±15
100±22
Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20
31,25Attenuation, dB, max
2,1
3,8
6
7,6
8,5
10,8NEXT, dB, min
75,3
66,3
60,3
57,3
55,8
52,8PS NEXT, dB, min
72,3
63,3
57,3
54,3
52,8
49,8ELFEXT, dB, min
68
56
48
44
42
38PS ELFEXT, dB, min
65
53
45
41
39
35RL, dB, min
20,0
23,0
25,0
25,0
25,0
23,6Frequency, MHz
62,5
100
250Attenuation, dB, max
15,5
19,9
33NEXT, dB, min
48,3
45,3
39,3PS NEXT, dB, min
45,3
42,3
36,3ELFEXT, dB, min
32
28
20PS ELFEXT, dB, min
29
25
17RL, dB, min
21,5
20,1
17,3IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT6 UTP 4x2x23 AWG Indoor
-
Application
Designed for connection home acoustics (speakers, music centers, home cinemas), lengthening speaker cords.
Cable design
- Conductor: copper wire (conductor structure complies with VDE 0295 class 6)
- Sheath: ion stable PVC (transparent with a longitudinal black stripe).
Installation and operation conditions
Temp Rating:
- Installation Temp Rating: -10 °C … +50 °C;
- Operating Temp Range: -20 °C … +70 °C.
Min Bend Radius: 5 cable diameters.
Main technical and mechanical characteristics
Cable brand Resistance, Ohm/km Capacitance, pF/m Inductance, mH/k
Loudspeaker Cable 2*0,75 Hi-Fi
23,5 60 0,61Nomenclature and mass-dimensional characteristics
Cable brand Outside diameter, mm Weight, kg/km
Loudspeaker Cable 2*0,75 Hi-Fi
2,5х5,4
27,1Loudspeaker cable 2×0,75 mm²
-
Application
Designed for connection home acoustics (speakers, music centers, home cinemas), lengthening speaker cords.
Cable design
- Conductor: copper wire (conductor structure complies with VDE 0295 class 6)
- Sheath: ion stable PVC (transparent with a longitudinal black stripe).
Installation and operation conditions
Temp Rating:
- Installation Temp Rating: -10 °C … +50 °C;
- Operating Temp Range: -20 °C … +70 °C.
Min Bend Radius: 5 cable diameters.
Main technical and mechanical characteristics
Cable brand Resistance, Ohm/km Capacitance, pF/m Inductance, mH/k
Loudspeaker Cable 2*0,75 Hi-Fi
12,5 67 0,54Nomenclature and mass-dimensional characteristics
Cable brand Outside diameter, mm Weight, kg/km
Loudspeaker Cable 2*0,75 Hi-Fi
3,5х7,4
54,7Loudspeaker cable 2×1,5 mm²