Electric parameters:
| Impendance | Ohm | 75+/-2 | |
| Capacity | pF/m | 54,5+/-3 | |
| Velocity ratio | % | 85 | |
| DC resistance (20 ºC) | Conductor | Ohm/km | 22,5 |
| Outer shield | Ohm/km | 24,0 | |
| Attenuation (20 ºC) | 1 MHz | dB/100 m | 0,68 |
| 5 MHz | dB/100 m | 1,53 | |
| 10 MHz | dB/100 m | 2,17 | |
| 50 MHz | dB/100 m | 4,85 | |
| 100 MHz | dB/100 m | 6,87 | |
| 200 MHz | dB/100 m | 9,74 | |
| 300 MHz | dB/100 m | 11,95 | |
| 470 MHz | dB/100 m | 14,98 | |
| 862 MHz | dB/100 m | 20,37 | |
| 1000 MHz | dB/100 m | 21,97 | |
| 1350 MHz | dB/100 m | ||
| 1750 MHz | dB/100 m | ||
| 2150 MHz | dB/100 m | ||
| Return loss at | 30-470 MHz | dB | >23 |
| 470-862 MHz | dB | >20 | |
| 862-2150 MHz dB | dB | >18 | |
| Screening efficiency | 5-10 MHz dB | dB | >75 |
| 10-30 MHz dB | dB | >85 | |
| 30-1000 MHz dB | dB | >90 |
Construction:
| Material conductor | Bare copper | ||
| Diameter conductor | Ø | mm | 1,02 |
| Material dielectric | FHDPE | ||
| Diameter dielectric | Ø | mm | 4,3±0,15 |
| Type of foil | Al/Pet/Al | ||
| Braiding material | Annealed tinned copper | ||
| Braid coverage | % | 60 | |
| Power wires | Copper (2 x 0,75 mm2) | ||
| Outer jacket | PVC | ||
| Diameter sheath | Ø | mm | 6,8/15,6 |
| Min. Setting radius | mm | 50 |