• LAN Cable CAT 5 F/UTP 2x2x24 AWG outdoor

    DESIGN

    1. Conductor: soft copper Diameter: 0,51 mm (±0,005 mm)
    2. Insulation: PE . Conductor diameter: 1,03 mm
    3. Pair: two conductors twisted together. Color identification of pairs: white-blue / blue and white – orange / orange
    4. Core wrapping
    5. Copper tinned contact wire Ø 0,4 mm is applied between the sheath and shield.
    6. Core shield: aluminum polymer foil (metal inside)
    7. Sheath: PE, nominal cable diameter: 6,0 mm, color: black

    APPLICATION

    PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s,

    100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s,

    Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, ATM LAN 1,2 Gbit/s

    СOMPLIANCE WITH THE REQUIREMENTS

    ISO/IEC 11801:2002, EN 50173-1:2002, ANSI/TIA/EIA-568-B.2-1-2002, IEC 61156-5:2002, TU U 31.3-05758730-020-2002

    MECHANICAL CHARACTERISTICS

    Тemperature range:

    During installation -10 °C … +60 °C

    After installation -50 °C … +60 °C

    Bending radius:

    During installation ≥ 8 cable diameters After installation ≥ 4 cable diameters

    Tensile stress ≤ 85 N

    ELECTRICAL CHARACTERISTICS AT 20 °C

    Parameter
    Unit
    Value

    Capacitance
    pF/m
    ≤ 56

    Direct current resistance
    Оhm/km
    ≤ 100

    Insulation resistance
    GOhm/km
    ≥ 5

    Resistance unbalance
    %
    2

    Signal propagation velocity
    s
    0,65

    Characteristic impedance in the frequency range of:
    Ohm
    100±15

    Test voltage between cores, (DC, 2 s)
    kV
    2,5

     

    Frequency, MHz
    1
    4
    10
    16
    20

    Attenuation, dB, max
    2,1
    4,1
    6,5
    8,3
    9,3

    NEXT, dB, min
    65,3
    56,2
    50,3
    47,2
    45,7

    PS NEXT, dB, min
    62,3
    53,2
    47,3
    44,2
    42,7

    ELFEXT, dB, min
    64
    51,9
    44
    39,9
    37,9

    PS ELFEXT, dB, min
    61
    48,9
    41
    36,9
    34,9

    RL, dB, min
    20
    23
    25
    25
    25

    Frequency, MHz
    31,25
    62,5
    100

    Attenuation, dB, max
    11,7
    17,0
    22,0

    NEXT, dB, min
    42,8
    38,3
    35,3

    PS NEXT, dB, min
    39,8
    35,3
    32,3

    ELFEXT, dB, min
    34,1
    28
    24

    PS ELFEXT, dB, min
    31,1
    25
    21

    RL, dB, min
    23,6
    21,5
    20,1

    IEC 61156-5, values lower than 4 MHz are given for information only

  • LAN Cable CAT 5 SF/UTP 4x2x23 AWG

    APPLICATION

    PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T

    СOMPLIANCE WITH THE REQUIREMENTS

    Cable: IEC 61156-5 (cat.5e)

    Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)

    Fire safety: IEC 60332-1, CPR class Eca

    MECHANICAL CHARACTERISTICS

    Тemperature range:

    · During installation -10 °C … +60 °C

    · After installation -20 °C … +60 °C
    Bending radius:

    · During installation ≥ 8 cable diameters

    · After installation ≥ 4 cable diameters
    Tensile stress ≤ 85 N

     

    ELECTRICAL CHARACTERISTICS AT 20 °C

    Parameter
    Unit
    Value

    Capacitance
    pF/m
    ≤ 56

    Direct current resistance for

    conductors with Ø:

    0,51 mm

    0,48 mm

    0,46 mm

    0,44 mm
    Оhm/km
     

     

    ≤ 92

    ≤ 103

    ≤ 112

    ≤ 123

    Insulation resistance
    GOhm*km
    ≥ 5

    Resistance unbalance
    %
    2

    Signal propagation velocity
    s
    0,69

    Characteristic impedance in the

    frequency range of: 1-100 MHz
    Ohm
    100±15

    Test voltage between cores, (DC, 2 s)
    kV
    2,5

     

    Frequency, MHz
    1
    4
    10
    16
    20

    Attenuation, dB, max; for max. cable lengths with conductor Ø:
    2,1
    4,1
    6,5
    8,3
    9,3

    0,51 mm = 104 m

    0,48 mm = 92 m

    0,46 mm = 84 m

    0,44 mm = 77 m

    NEXT, dB, min
    65,3
    56,3
    50,3
    47,2
    45,8

    PS NEXT, dB, min
    62,3
    53,3
    47,3
    44,2
    42,8

    ELFEXT, dB, min
    64
    52
    44
    40
    38

    PS ELFEXT, dB, min
    61
    49
    41
    37
    35

    RL, dB, min
    20,0
    23,0
    25,0
    25,0
    25,0

    Frequency, MHz
    31,25
    62,5
    100

    Attenuation, dB, max; for max. cable lengths with conductor Ø:
    11,7
    17,0
    22,0

    0,51 mm = 104 m

    0,48 mm = 92 m

    0,46 mm = 84 m

    0,44 mm = 77 m

    NEXT, dB, min
    42,9
    38,4
    35,3

    PS NEXT, dB, min
    39,9
    35,4
    32,3

    ELFEXT, dB, min
    34
    28,1
    24

    PS ELFEXT, dB, min
    31
    25,1
    21

    RL, dB, min
    23,6
    21,5
    20,1

    IEC 61156-5, values lower than 4 MHz are given for information only

  • LAN Cable CAT 5 U/UTP 2x2x24 AWG indoor

    Application

    PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s

    Installation and Operation Conditions

    For outdoor installation in telephone ducts, collectors, mines, on the walls of buildings in conditions of heightened electro-magnetic impacts.
    Operated on frequencies up to 250 MHz

    Compliance with the requirements

    Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568-C.2

    Cable: IEC 61156-2

    Mechanical Characteristics

    Temperature range:    During installation -10 °C … +60 °C

    After installation -20 °C … +60 °C

    Bending radius:            During installation ≥ 8 cable diameters

    After installation ≥ 4 cable diameters

    Tensile stress ≤ 85 N

     

    ELECTRICAL CHARACTERISTICS AT 20 °C

    Parameter
    Unit
    Value

    Capacitance
    pF/m
    ≤ 56

    Direct current resistance
    Оhm/km
    ≤ 95

    Insulation resistance
    GOhm/km
    ≥ 5

    Resistance unbalance
    %
    2

    Signal propagation velocity
    s
    0,68

    Propagation delay
    ns/100 m
    ≤ 534+36/√f

    Delay shift on the frequency 100 MHz
    ns/100 m
    ≤ 30

    Characteristic impedance in the frequency range of:

    1-100 MHz
     

    Ohm
     

    100±15

    Test voltage between cores, (DC, 2 s)
    kV
    2,5

     

    Frequency, MHz
    1
    4
    10
    16
    20

    Attenuation, dB, max:
    2,1
    4,1
    6,5
    8,3
    9,3

    NEXT, dB, min
    65,3
    56,3
    50,3
    47,2
    45,8

    ELFEXT, dB, min
    64
    52
    44
    40
    38

    RL, dB, min
    20,0
    23,0
    25,0
    25,0
    25,0

    Frequency, MHz
    31,25
    62,5
    100

    Attenuation, dB, max:
    11,7
    17,0
    22,0

    NEXT, dB, min
    42,9
    38,4
    35,3

    ELFEXT, dB, min
    34
    28
    24

    RL, dB, min
    23,3
    20,7
    19,0

    IEC 61156-5, values lower than 4 MHz are given for information only

     

  • LAN Cable CAT 5E LSZH F/UTP 4x2x24 AWG Indoor Cable

              APPLICATION:

    • PBX
    • V.11
    • X.21
    • ISDN
    • Ethernet (10Base-T)
    • ATM-25/52/155 Mbit/s
    • 100VG-AnyLAN
    • Fast Ethernet (100BASE-TX)
    • Token Ring 16/100 Mbit/s
    • Firewire 100 Mbit/s
    • PoE (IEEE 802.3af)
    • PoE+ (IEEE 802.3at)
    • PoE++ (IEEE 802.3bt)
    • HDBaseT
    • 1000BASE-T
    • 2.5GBASE-T
    • 5GBASE-T (up to 55 meters)

      DESIGN:
    • Conductor: solid annealed copper
    • Insulation: LSZH
    • Pair: two conductors twisted together
    • Core wrapping
    • Copper tinned contact wire Ø 0,4 mm
    • Core shield: aluminum polymer foil (metal outside)
    • Jacket: PVC, LSZH, LSFRZH
    • СOMPLIANCE WITH THE REQUIREMENTS:
    • Cable: IEC 61156-5 (cat.5e)
    • Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
    • Fire safety: IEC 60332-1, CPR class EcaMECHANICAL CHARACTERISTICS:
    • Temperature range:
      – During installation -10 °C … +60 °C
      – After installation -20 °C … +60 °C
    • Bending radius:
      – During installation ≥ 8 cable diameters
      – After installation ≥ 4 cable diameters
      Tensile stress ≤ 85 N

      ELECTRICAL CHARACTERISTICS AT 20 °C:
    • Capacitance: pF/m ≤ 56
    • Direct current resistance for conductors: Оhm/km ≤ 95
    • Resistance unbalance: % 2
    • Insulation resistance: GOhm/km ≥ 5
    • Signal propagation velocity: % 68
    • Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
    • Test voltage between cores, (DC, 2 s): kV 2,5
  • LAN Cable CAT 5E U/UTP 4x2x24 AWG Indoor Cable

              APPLICATION:

    • PBX
    • V.11
    • X.21
    • ISDN
    • Ethernet (10Base-T)
    • ATM-25/52/155 Mbit/s
    • 100VG-AnyLAN
    • Fast Ethernet (100BASE-TX)
    • Token Ring 16/100 Mbit/s
    • Firewire 100 Mbit/s
    • PoE (IEEE 802.3af)
    • PoE+ (IEEE 802.3at)
    • PoE++ (IEEE 802.3bt)
    • HDBaseT
    • 1000BASE-T
    • 2.5GBASE-T
    • 5GBASE-T (up to 55 meters)

      DESIGN:
    • Conductor: solid annealed copper
    • Insulation: solid PE
    • Pair: two conductors twisted together
    • Core wrapping
    • Jacket: PVC, color RAL 7035
    • СOMPLIANCE WITH THE REQUIREMENTS:
    • Cable: IEC 61156-5 (cat.5e)
    • Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
    • Fire safety: IEC 60332-1, CPR class Eca 

      MECHANICAL CHARACTERISTICS:

    • Temperature range:
      – During installation -10 °C … +60 °C
      – After installation -20 °C … +60 °C
    • Bending radius:
      – During installation ≥ 8 cable diameters
      – After installation ≥ 4 cable diameters
      Tensile stress ≤ 85 N

      ELECTRICAL CHARACTERISTICS AT 20 °C:
    • Capacitance: pF/m ≤ 56
    • Direct current resistance for conductors(-0.51 mm; -0.50mm): Оhm/km ≤ 92-95
    • Resistance unbalance: % 2
    • Insulation resistance: GOhm/km ≥ 5
    • Signal propagation velocity: % 68
    • Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
    • Test voltage between cores, (DC, 2 s): kV 2,5