Optics Specifications
Attenuation(dB/km)
@1310nm
≤0.34db/km@1383nm (after hydrogen aging)
≤0.32db/km@1550nm
≤0.20db/km@1625nm
≤0.24db/kmDispersion
@1285nm~1340nm
-3.0~3.0ps/(nm*km)@1550nm
≤18ps/(nm*km)@1625nm
≤22ps/(nm*km)Zero-Dispersion wavelength
1300~1324nmZero-Dispersion slope
≤0.092ps/(nm2*km)Mode field diameter @ 1310nm
9.2±0.4μmMode field diameter @ 1550nm
10.4±0.8μmPMD
Max. value for fiber on the reel
0.2ps/km 1/2Max. Designed value for link
0.08ps/km 1/2Cable cutoff wavelength,λ cc
≤1260nmEffective group index(Neff)@1310nm
1.4675Effective group index(Neff)@1550nm
1.4680Macro-bend loss(Φ60mm,100 turns)@1550nm
≤0.05dbBack scatter characteristic(@1310nm&1550nm)
Point discontinuity
≤0.05dbAttenuation uniformity
≤0.05db/kmAttenuation coefficient difference for bi-directional measurement
≤0.05db/kmGeometrical characteristics
Cladding diameter
125±1μmCladding non-circularity
≤1%Core/cladding concentricity error
≤0.4μmFiber diameter with coating(uncolored)
245±5μmCladding/coating concentricity error
≤12.0μmCurl
≥4mMechanical characteristic
Proof test
0.69GPaCoating strip force(typical value)
1.4NDynamic stress corrosion susceptibility parameter(typical value)
≥20Environmental characteristics(@1310nm&1550nm)
Temperature induced attenuation(-60~+85℃)
≤0.5dB/kmDry heat induced attenuation(85±2℃,30days)
≤0.5dB/kmWater immersion induced attenuation(23±2℃,30days)
≤0.5dB/kmDamp heat induced attenuation(85±2℃,RH85%,30days)
≤0.5dB/kmFiber count
2
4
6
8
12Fiber No. per tube
2
4
6
8
12Loose tube diameter/Material
2.2+0.2mm/PBTOuter sheath thickness &Material
1.5-1.8mm HDPEStrength member
Steel tape +Two steel wireCable overall diameter
8.5±0.2mmCable weight
Approx 65 kg/kmOperation temperature range
-40 ℃ to + 70 ℃Installation temperature range
-40 ℃ to + 70 ℃Transport and storage temperature
range
– 40 ℃ to + 70 ℃Allowable Tensile Load(N)
2000NCrush resistance
Short term :2200N/100MM Long term:1100N/100MM
Minimal installation bending radius
20 x ODMinimal operation bending radius
10 x ODFiber Optic Cable Armoured 9125 outdoor Multi-tube
-
Fiber count
2
4
6
8
12Max. No of loose tube
1Fiber No. per tube
2
4
6
8
12Loose tube diameter
2.0±0.1mmOuter sheath thickness
1.6±0.1mmMessenger wire
1.0MM*7pcs galvanized steelOuter sheath material
HDPECable OD mm
10.6-11MM *5.0-5.2MMCable weight
66KG/KMTensile
3KNOperation temperature range
-40 d℃ to + 70 ℃Installation temperature range
-40 ℃ to + 70 ℃Transport and storage temperature
range
-40 ℃ to + 70 ℃Crush resistance
1000 N/10cmMinimal installation bending radius
20 x ODMinimal operation bending radius
10 x ODFiber Optic Cable Aerial 9/125 outdoor Multi-tube
-
- Impendance: 75+/-3 Ohm
- Capacity: 55+/-3 pF/m
- Velocity ratio: 80 %
- DC resistance (20 ºC) Conductor: 63,1 Ohm/km
Outer shield: 40,6 Ohm/km - Attenuation (20 ºC): 5 MHz 2,62 dB/100 m
50 MHz 8,40 dB/100 m
200 MHz 16,87 dB/100 m
470 MHz 25,97 dB/100 m
500 MHz 26,80 dB/100 m
862 MHz 35,32 dB/100 m
1000 MHz 38,09 dB/100 m - Return loss at: 30-470 MHz dB >20
470-862 MHz dB >23
862-2150 MHz dB >18 - Screening efficiency: 5-10 MHz dB >70
10-30 MHz dB >80
30-1000 MHz dB >85
CCTV Cable 1+2 Mini U4 2×0,50 500M
-
Fiber count: 1/2/4
Color of fiber: Blue, Orange, Green, Brown, Grey
Fiber Type: G657A2
Strength member: Steel wire/FRP
Supporting messenger wire: 1.0MM*x1 steel wire
Outer sheath: LSZH Lower smoke zero halogen frame retardant & UV Anti
Cable Diameter dimensions: 2.0( Height) × 5.0W ± 0.1 mm(width)
Operation temperature range: -20 ℃ to + 70 ℃
Installation temperature range: -20 ℃ to + 60 ℃
Transport and storage temperature range: -20 ℃ to + 70 ℃
Tension Load (N): Short term :800N Long term :500N
Crush Load(N): Long term 1000 N/100mm Short term:2200N/100mm
Minimal installation bending radius: 30 x OD
Minimal operation bending radius: 15 x OD
Cable marking: The marking length 1meter apart , as requiredCategory
Description
G657A1
G657A2/B2Standard
StandardOptical transmission performance
Attenuation coefficient
1310nm
≤0.35
≤0.351383nm
≤0.35
≤0.351550nm
≤0.21
≤0.211625nm
≤0.23
≤0.23Attenuation inhomogeneity
1310nm、1550nm
≤0.03
≤0.05Attenuation discontinuity
1310nm、1550nm
≤0.03
≤0.05Wavelength attenuation
characteristics
1288~1330nm
≤0.05
≤0.051525~1575nm
≤0.05
≤0.05Dispersion characteristic
The zero dispersion wavelengthnm
1300~1324
1300~1324Zero dispersion slope
≤0.092
≤0.0921288~1339nm
≤3.5
≤3.51271~1360nm
≤5.3
≤5.31550nm
≤18
≤181625nm
≤22
≤22The polarization mode dispersion of the fiber
≤0.1
≤0.1Fiber cutoff wavelength
≤1260
≤1260Macro bending loss
(10 laps,30mm)
1550nm
≤0.2dB
≤0.03(10 laps,30mm)
1625nm
≤0.5dB
≤0.1(1 lap,20mm)
1550nm
≤0.3dB
≤0.1(1 lap,20mm)
1625nm
≤1.0dB
≤0.2(1 lap,15mm)
1550nm
–
≤0.5(1 lap,15mm)
1625nm
–
≤1.0Mode field diameter
1310nm
8.8±0.4
8.6±0.4Dimension parameter
Warp degrees
≥4.0
≥4.0Cladding diameter
125 ± 0.7
125 ± 0.7Core/package concentricity
≤0.5
≤0.5Cladding non-circularity
≤1.0%
≤1.0%Coating diameter
243± 5
243± 5Coating concentricity
≤8
≤8Coating roundness
≤3%
≤3%Mechanical property
Strain
≥1.05%
≥1.05%Tensile strength(10m)
15% Weber fracture probability
2.76
2.76
50% Weber fracture probability
3.45
3.45Fatigue parameters Nd
≥ 22
≥ 22Coating peak stripping force N
1.0~8.9
1.0~8.9Coating average stripping force N
1.0~5.0
1.0~5.0Environmental performance
Additional damping temperature cycle (-60℃ ~ +85℃)dB/km@1310nm,1550nm, 1625 nm
≤ 0.05
≤ 0.05Wet and heat aging (+85±2℃, 85%RH,30 days) dB/km@1310nm,
≤ 0.05
≤ 0.05
1550nm, 1625 nm
High temperature aging(85±2℃,30 days ) dB/km @1310nm,1550
nm, 1625 nm
≤ 0.05
≤ 0.05Additional attenuation of flooding (23±2℃,30 days ) dB/km
@1310nm,1550nm, 1625 nm
≤ 0.05
≤ 0.05Fiber Optic DROP Cable FO1 Aerial outdoor G657A2
-
The typical bow-type drop optical cable includes central optical fibers with 2 Steel wire as the strength members placed on both sides, a LSZH sheath is extruded outside.
Fiber Optical
Fiber count
1/2Color Of fiber
Blue OrangeFiber Type
G657A2Strength member
Galvanized steel wireOuter sheath
LSZH(white)Cable Diameter dimensions
2.0( Height) × 3.0W ± 0.1 mm(width)Operation temperature range
-20 ℃ to + 70 ℃Installation temperature range
-0 ℃ to + 60 ℃Transport and storage temperature range
-20 ℃ to + 70 ℃Minimal installation bending radius
30 x ODMinimal operation bending radius
15 x ODCable marking
The marking length 1meter apart , as requiredG657A2 fiber
Category
Description
G657A1
G657A2/B2Standard
StandardOptical transmission performance
Attenuation coefficient
1310nm
≤0.35
≤0.351383nm
≤0.35
≤0.351550nm
≤0.21
≤0.211625nm
≤0.23
≤0.23Attenuation inhomogeneity
1310nm、1550nm
≤0.03
≤0.05Attenuation discontinuity
1310nm、1550nm
≤0.03
≤0.05Wavelength attenuation
characteristics
1288~1330nm
≤0.05
≤0.051525~1575nm
≤0.05
≤0.05Dispersion characteristic
The zero dispersion wavelengthnm
1300~1324
1300~1324Zero dispersion slope
≤0.092
≤0.0921288~1339nm
≤3.5
≤3.51271~1360nm
≤5.3
≤5.31550nm
≤18
≤181625nm
≤22
≤22The polarization mode dispersion of the fiber
≤0.1
≤0.1Fiber cutoff wavelength
≤1260
≤1260Macro bending loss
(10 laps,30mm)
1550nm
≤0.2dB
≤0.03(10 laps,30mm)
1625nm
≤0.5dB
≤0.1(1 lap,20mm)
1550nm
≤0.3dB
≤0.1(1 lap,20mm)
1625nm
≤1.0dB
≤0.2(1 lap,15mm)
1550nm
–
≤0.5(1 lap,15mm)
1625nm
–
≤1.0Mode field diameter
1310nm
8.8±0.4
8.6±0.4Dimension parameter
Warp degrees≥4.0
≥4.0Cladding diameter
125 ± 0.7
125 ± 0.7Core/package concentricity
≤0.5
≤0.5Cladding non-circularity
≤1.0%
≤1.0%Coating diameter
243± 5
243± 5Coating concentricity
≤8
≤8Coating roundness
≤3%
≤3%Mechanical property
Strain≥1.05%
≥1.05%Tensile strength(10m)
15% Weber fracture probability
2.76
2.7650% Weber fracture probability
3.45
3.45Fatigue parameters Nd
≥ 22
≥ 22Coating peak stripping force N
1.0~8.9
1.0~8.9Coating average stripping force N
1.0~5.0
1.0~5.0Environmental
performance
Additional damping temperature cycle (-60℃ ~ +85℃)dB/km@1310nm,1550nm, 1625 nm
≤ 0.05
≤ 0.05Wet and heat aging (+85±2℃, 85%RH,30 days) dB/km@1310nm,
1550nm, 1625 nm
≤ 0.05
≤ 0.05High temperature aging(85±2℃,30 days ) dB/km @1310nm,1550
nm, 1625 nm
≤ 0.05
≤ 0.05Additional attenuation of flooding (23±2℃,30 days ) dB/km
@1310nm,1550nm, 1625 nm
≤ 0.05
≤ 0.05Fiber Optic DROP Cable FO1 SM indoor G657A2
-
Fiber count
2
4
6
8
12Max. No of loose tube
1Fiber No. per tube
2
4
6
8
12Loose tube diameter
2.0±0.1mmOuter sheath thickness
1.6±0.1mmMessenger wire
1.0MM*7pcs galvanized steelOuter sheath material
HDPECable OD mm
10.6-11MM *5.0-5.2MMCable weight
66KG/KMTensile
3KNOperation temperature range
-40 d℃ to + 70 ℃Installation temperature range
-40 ℃ to + 70 ℃Transport and storage temperature
range
-40 ℃ to + 70 ℃Crush resistance
1000 N/10cmMinimal installation bending radius
20 x ODMinimal operation bending radius
10 x ODFiber Optic Cable Aerial 9/125 outdoor Uni-tube
-
The typical bow-type drop optical cable includes central optical fibers with 2 Steel wire as the strength members placed on both sides, a LSZH sheath is extruded outside.
Fiber Optical
Fiber count
1/2Color Of fiber
Blue OrangeFiber Type
G657A2Strength member
Galvanized steel wireOuter sheath
LSZH(white)Cable Diameter dimensions
2.0( Height) × 3.0W ± 0.1 mm(width)Operation temperature range
-20 ℃ to + 70 ℃Installation temperature range
-0 ℃ to + 60 ℃Transport and storage temperature range
-20 ℃ to + 70 ℃Minimal installation bending radius
30 x ODMinimal operation bending radius
15 x ODCable marking
The marking length 1meter apart , as requiredG657A2 fiber
Category
Description
G657A2/B2Optical
transmission
performance
Attenuation coefficient
1310nm
≤0.351383nm
≤0.351550nm
≤0.211625nm
≤0.23Attenuation inhomogeneity
1310nm, 1550nm
≤0.05Attenuation discontinuity
1310nm, 1550nm
≤0.05Wavelength attenuation
characteristics
1228 ~ 1330nm
≤0.051525 ~ 1575nm
≤0.05Dispersion characteristic
The zero dispersion wavelength nm
1300~1324Zero dispersion slope
≤0.0921288~1339nm
≤3.51271~1360nm
≤5.31550nm
≤181625nm
≤22The polarization mode dispersion of the fiber
≤0.1Fiber cutoff wavelength
≤1260Macro bending loss
(10 laps,30mm)
1550nm
≤0.03(10 laps,30mm)
1625nm
≤0.1(1 lap,20mm)
1550nm
≤0.1(1 lap,20mm)
1625nm
≤0.2(1 lap,15mm)
1550nm
≤0.5(1 lap,15mm)
1625nm
≤1.0Mode field diameter
1310nm
8.6±0.4Dimension
parameter
Warp degrees≥4.0
Cladding diameter
125 ± 0.7
Core/package concentricity
≤0.5
Cladding non-circularity
≤1.0%
Coating diameter
243± 5
Coating concentricity
≤8
Coating roundness
≤3%
Mechanical
property
Strain≥1.05%
Tensile strength(10m)
15% Weber fracture probability
2.7650% Weber fracture probability
3.45Fatigue parameters Nd
≥ 22
Coating peak stripping force N
1.0~8.9
Coating average stripping force N
1.0~5.0
Environmental
performance
Additional damping temperature cycle (-60℃ ~ +85℃)
dB/km@1310nm,1550nm, 1625 nm
≤ 0.05Wet and heat aging (+85±2℃, 85%RH,30 days) dB/km@1310nm, 1550nm, 1625 nm
≤ 0.05High temperature aging(85±2℃,30 days ) dB/km @1310nm, 1550nm, 1625 nm
≤ 0.05Additional attenuation of flooding (23±2℃,30 days ) dB/km
@1310nm,1550nm, 1625 nm
≤ 0.05Fiber Optic DROP Cable FO2 SM indoor G657A2
-
Fiber count
2-8
12Fiber type
Single Mode G652DMax. No of loose tube
1Fiber No. per tube
2-8
12Loose tube diameter
1.6mm
2.0mmOuter sheath thickness
1.5mmFRP Strength member
0.8mm
1.0mmOuter sheath
HDPECable OD mm
4.6±0.2mm
5.8±0.2mmCable weight kg/km
19
30Operation temperature range
-40 d℃ to + 70 ℃Installation temperature range
-40 ℃ to + 70 ℃Transport and storage temperature range
-40 ℃ to + 70 ℃Allowable Tensile Load(N)
Short term:1500 Long term:600Crush resistance
1000 N/10cm 2200N/10CMMinimal installation bending radius
20 x ODMinimal operation bending radius
10 x ODFiber Optic Cable SM 9125 outdoor
-
Electric parameters:
Impedance
Ohm
75+/-3Capacity
pF/m
54.5+/-3Velocity ratio
%
85DC resistance (20 ºC)
Conductor
Ohm/km
35.5Outer shield
Ohm/km
31Attenuation (20 ºC)
1 MHz
db/100 m
0.875 MHz
db/100 m
1.9810 MHz
db/100 m
2.7950 MHz
db/100 m
6.25100 MHz
db/100 m
8.91200 MHz
db/100 m
12.9300 MHz
db/100 m
15.83470 MHz
db/100 m
19.41862 MHz
db/100 m
26.141000 MHz
db/100 m
28.921350 MHz
db/100 m1750 MHz
db/100 m2150 MHz
db/100 mReturn loss at
30-470 MHz
db
>23470-862 MHz
db
>20682-2150 MHz
db
>18Screening efficiency
5-10 MHz
db
>5510-30 MHz
db
>6030-1000 MHz
db
>65Construction:
Material conductor
Bare copper
Diameter conductor
mm
0.8Material dielectric
FHDPE
Diameter dielectric
mm
3,7±0,15Typf of foil
Al/Pet/Al
Braiding material
AM (aluminium)
Braid coverage
%
67Power wires
Copper (2 x 0,75 mm2)
Outer jacket
PVC
Diameter sheath
mm
6.1/12.0Min. Setting radius
mm
35CCTV Cable RG59 1+2 2×0,75 outdoor 500m
-
Optics Specifications
Attenuation(dB/km)
@1310nm
≤0.34db/km@1383nm (after hydrogen aging)
≤0.32db/km@1550nm
≤0.20db/km@1625nm
≤0.24db/kmDispersion
@1285nm~1340nm
-3.0~3.0ps/(nm*km)@1550nm
≤18ps/(nm*km)@1625nm
≤22ps/(nm*km)Zero-Dispersion wavelength
1300~1324nmZero-Dispersion slope
≤0.092ps/(nm2*km)Mode field diameter @ 1310nm
9.2±0.4μmMode field diameter @ 1550nm
10.4±0.8μmPMD
Max. value for fiber on the reel
0.2ps/km 1/2Max. Designed value for link
0.08ps/km 1/2Cable cutoff wavelength,λ cc
≤1260nmEffective group index(Neff)@1310nm
1.4675Effective group index(Neff)@1550nm
1.4680Macro-bend loss(Φ60mm,100 turns)@1550nm
≤0.05dbBack scatter characteristic(@1310nm&1550nm)
Point discontinuity
≤0.05dbAttenuation uniformity
≤0.05db/kmAttenuation coefficient difference for bi-directional measurement
≤0.05db/kmGeometrical characteristics
Cladding diameter
125±1μmCladding non-circularity
≤1%Core/cladding concentricity error
≤0.4μmFiber diameter with coating(uncolored)
245±5μmCladding/coating concentricity error
≤12.0μmCurl
≥4mMechanical characteristic
Proof test
0.69GPaCoating strip force(typical value)
1.4NDynamic stress corrosion susceptibility parameter(typical value)
≥20Environmental characteristics(@1310nm&1550nm)
Temperature induced attenuation(-60~+85℃)
≤0.5dB/kmDry heat induced attenuation(85±2℃,30days)
≤0.5dB/kmWater immersion induced attenuation(23±2℃,30days)
≤0.5dB/kmDamp heat induced attenuation(85±2℃,RH85%,30days)
≤0.5dB/kmFiber count
2
4
6
8
12Fiber No. per tube
2
4
6
8
12Loose tube diameter/Material
2.2+0.2mm/PBTOuter sheath thickness &Material
1.5-1.8mm HDPEStrength member
Steel tape +Two steel wireCable overall diameter
8.5±0.2mmCable weight
Approx 65 kg/kmOperation temperature range
-40 ℃ to + 70 ℃Installation temperature range
-40 ℃ to + 70 ℃Transport and storage temperature
range
– 40 ℃ to + 70 ℃Allowable Tensile Load(N)
2000NCrush resistance
Short term :2200N/100MM Long term:1100N/100MM
Minimal installation bending radius
20 x ODMinimal operation bending radius
10 x ODFiber Optic Cable Armoured 9125 outdoor Uni-tube
-
Application
Designed for connection home acoustics (speakers, music centers, home cinemas), lengthening speaker cords.
Cable design
- Conductor: copper wire (conductor structure complies with VDE 0295 class 6)
- Sheath: ion stable PVC (transparent with a longitudinal black stripe).
Installation and operation conditions
Temp Rating:
- Installation Temp Rating: -10 °C … +50 °C;
- Operating Temp Range: -20 °C … +70 °C.
Min Bend Radius: 5 cable diameters.
Main technical and mechanical characteristics
Cable brand Resistance, Ohm/km Capacitance, pF/m Inductance, mH/k
Loudspeaker Cable 2*0,75 Hi-Fi
12,5 67 0,54Nomenclature and mass-dimensional characteristics
Cable brand Outside diameter, mm Weight, kg/km
Loudspeaker Cable 2*0,75 Hi-Fi
3,5х7,4
54,7Loudspeaker cable 2×1,5 mm²
-
Application
Designed for connection home acoustics (speakers, music centers, home cinemas), lengthening speaker cords.
Cable design
- Conductor: copper wire (conductor structure complies with VDE 0295 class 6)
- Sheath: ion stable PVC (transparent with a longitudinal black stripe).
Installation and operation conditions
Temp Rating:
- Installation Temp Rating: -10 °C … +50 °C;
- Operating Temp Range: -20 °C … +70 °C.
Min Bend Radius: 5 cable diameters.
Main technical and mechanical characteristics
Cable brand Resistance, Ohm/km Capacitance, pF/m Inductance, mH/k
Loudspeaker Cable 2*0,75 Hi-Fi
23,5 60 0,61Nomenclature and mass-dimensional characteristics
Cable brand Outside diameter, mm Weight, kg/km
Loudspeaker Cable 2*0,75 Hi-Fi
2,5х5,4
27,1Loudspeaker cable 2×0,75 mm²
-
APPLICATION
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T
СOMPLIANCE WITH THE REQUIREMENTS
Cable: IEC 61156-5 (cat.5e)
Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
Fire safety: IEC 60332-1, CPR class Eca
MECHANICAL CHARACTERISTICS
Тemperature range:
· During installation -10 °C … +60 °C
· After installation -20 °C … +60 °C
Bending radius:· During installation ≥ 8 cable diameters
· After installation ≥ 4 cable diameters
Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance for
conductors with Ø:
0,51 mm
0,48 mm
0,46 mm
0,44 mm
Оhm/km
≤ 92
≤ 103
≤ 112
≤ 123
Insulation resistance
GOhm*km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,69Characteristic impedance in the
frequency range of: 1-100 MHz
Ohm
100±15Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20Attenuation, dB, max; for max. cable lengths with conductor Ø:
2,1
4,1
6,5
8,3
9,30,51 mm = 104 m
0,48 mm = 92 m
0,46 mm = 84 m
0,44 mm = 77 m
NEXT, dB, min
65,3
56,3
50,3
47,2
45,8PS NEXT, dB, min
62,3
53,3
47,3
44,2
42,8ELFEXT, dB, min
64
52
44
40
38PS ELFEXT, dB, min
61
49
41
37
35RL, dB, min
20,0
23,0
25,0
25,0
25,0Frequency, MHz
31,25
62,5
100Attenuation, dB, max; for max. cable lengths with conductor Ø:
11,7
17,0
22,00,51 mm = 104 m
0,48 mm = 92 m
0,46 mm = 84 m
0,44 mm = 77 m
NEXT, dB, min
42,9
38,4
35,3PS NEXT, dB, min
39,9
35,4
32,3ELFEXT, dB, min
34
28,1
24PS ELFEXT, dB, min
31
25,1
21RL, dB, min
23,6
21,5
20,1IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT 5 SF/UTP 4x2x23 AWG
-
Application
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s
Installation and Operation Conditions
For outdoor installation in telephone ducts, collectors, mines, on the walls of buildings in conditions of heightened electro-magnetic impacts.
Operated on frequencies up to 250 MHzCompliance with the requirements
Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568-C.2
Cable: IEC 61156-2
Mechanical Characteristics
Temperature range: During installation -10 °C … +60 °C
After installation -20 °C … +60 °C
Bending radius: During installation ≥ 8 cable diameters
After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance
Оhm/km
≤ 95Insulation resistance
GOhm/km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,68Propagation delay
ns/100 m
≤ 534+36/√fDelay shift on the frequency 100 MHz
ns/100 m
≤ 30Characteristic impedance in the frequency range of:
1-100 MHz
Ohm
100±15
Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20Attenuation, dB, max:
2,1
4,1
6,5
8,3
9,3NEXT, dB, min
65,3
56,3
50,3
47,2
45,8ELFEXT, dB, min
64
52
44
40
38RL, dB, min
20,0
23,0
25,0
25,0
25,0Frequency, MHz
31,25
62,5
100Attenuation, dB, max:
11,7
17,0
22,0NEXT, dB, min
42,9
38,4
35,3ELFEXT, dB, min
34
28
24RL, dB, min
23,3
20,7
19,0IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT 5 U/UTP 2x2x24 AWG indoor
-
DESIGN
- Conductor: soft copper Diameter: 0,51 mm (±0,005 mm)
- Insulation: PE . Conductor diameter: 1,03 mm
- Pair: two conductors twisted together. Color identification of pairs: white-blue / blue and white – orange / orange
- Core wrapping
- Copper tinned contact wire Ø 0,4 mm is applied between the sheath and shield.
- Core shield: aluminum polymer foil (metal inside)
- Sheath: PE, nominal cable diameter: 6,0 mm, color: black
APPLICATION
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s,
100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s,
Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, ATM LAN 1,2 Gbit/s
СOMPLIANCE WITH THE REQUIREMENTS
ISO/IEC 11801:2002, EN 50173-1:2002, ANSI/TIA/EIA-568-B.2-1-2002, IEC 61156-5:2002, TU U 31.3-05758730-020-2002
MECHANICAL CHARACTERISTICS
Тemperature range:
During installation -10 °C … +60 °C
After installation -50 °C … +60 °C
Bending radius:
During installation ≥ 8 cable diameters After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance
Оhm/km
≤ 100Insulation resistance
GOhm/km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,65Characteristic impedance in the frequency range of:
Ohm
100±15Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20Attenuation, dB, max
2,1
4,1
6,5
8,3
9,3NEXT, dB, min
65,3
56,2
50,3
47,2
45,7PS NEXT, dB, min
62,3
53,2
47,3
44,2
42,7ELFEXT, dB, min
64
51,9
44
39,9
37,9PS ELFEXT, dB, min
61
48,9
41
36,9
34,9RL, dB, min
20
23
25
25
25Frequency, MHz
31,25
62,5
100Attenuation, dB, max
11,7
17,0
22,0NEXT, dB, min
42,8
38,3
35,3PS NEXT, dB, min
39,8
35,3
32,3ELFEXT, dB, min
34,1
28
24PS ELFEXT, dB, min
31,1
25
21RL, dB, min
23,6
21,5
20,1IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT 5 F/UTP 2x2x24 AWG outdoor
-
APPLICATION
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155
Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, 10 Gigabit Ethernet (10GBASE-T*), ATM LAN 1,2 Gbit/s
INSTALLATION AND OPERATION CONDITIONS
For stationary installation inside buildings, stations, structures and equipment in conditions of heightened electromagnetic impacts. Operated on frequencies up to 250 MHz.
СOMPLIANCE WITH THE REQUIREMENTS
System: ISO/IEC 11801, EN 50173-1, ANSI/TIA 568-С.2 Cable: IEC 61156-5
Fire safety: IEC 60332-1, IEC 61034-1, IEC 60754-2
CPR class: Eca
MECHANICAL CHARACTERISTICS
Тemperature range:
During installation -10 °C … +60 °C / After installation -20 °C … +60 °C
Bending radius:
During installation ≥ 8 cable diameters / After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance
Оhm/km
≤ 85Insulation resistance
GOhm/km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,68Propagation delay
ns/100 m
≤ 534+36/√fDelay shift on the frequency 100 MHz
ns/100 m
≤ 30Characteristic impedance in the frequency range of: 1-100 MHz
100-250 MHz
Ohm
100±15
100±22
Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20
31,25Attenuation, dB, max
2,1
3,8
6
7,6
8,5
10,8NEXT, dB, min
75,3
66,3
60,3
57,3
55,8
52,8PS NEXT, dB, min
72,3
63,3
57,3
54,3
52,8
49,8ELFEXT, dB, min
68
56
48
44
42
38PS ELFEXT, dB, min
65
53
45
41
39
35RL, dB, min
20,0
23,0
25,0
25,0
25,0
23,6Frequency, MHz
62,5
100
125
200
250Attenuation, dB, max
15,5
19,9
22,5
29,1
33NEXT, dB, min
48,3
45,3
43,8
40,8
39,3PS NEXT, dB, min
45,3
42,3
40,8
37,8
36,3ELFEXT, dB, min
32
28
26
22
20PS ELFEXT, dB, min
29
25
23
19
17RL, dB, min
21,5
20,1
19,4
18,0
17,3IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT 6 F/UTP LSZH 4x2x23 AWG
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T (up to 55 meters)
DESIGN:
- Conductor: solid annealed copper
- Insulation: PE
- Pair: two conductors twisted together:
– Pair 1: white-blue / blue
– Pair 2: white-orange / orange
– Pair 3: white-green / green
– Pair 4: white – brown / brown - Cross-web (PE or LSFRZH)
- Core wrapping
- Core shield: aluminum polymer foil (metal outside)
- Copper tinned contact wire Ø 0,4 mm
- Jacket: PVC, LSZH, LSFRZH
- MECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius: ≥ 10 cable diameters
- Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors(0,54 mm; 0,57 mm): Оhm/km ≤ 83-88
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 6 F/UTP 4x2x23 AWG Indoor Cable
-
- Impendance: 75+/-3 Ohm
- Capacity: 55+/-3 pF/m
- Velocity ratio: 80 %
- DC resistance (20 ºC) Conductor: 63,1 Ohm/km
Outer shield: 40,6 Ohm/km - Attenuation (20 ºC): 5 MHz 2,62 dB/100 m
50 MHz 8,40 dB/100 m
200 MHz 16,87 dB/100 m
470 MHz 25,97 dB/100 m
500 MHz 26,80 dB/100 m
862 MHz 35,32 dB/100 m
1000 MHz 38,09 dB/100 m - Return loss at: 30-470 MHz dB >20
470-862 MHz dB >23
862-2150 MHz dB >18 - Screening efficiency: 5-10 MHz dB >70
10-30 MHz dB >80
30-1000 MHz dB >85
CCTV Cable 1+4 Mini U4 2×0,50 500M
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T (up to 55 meters)
DESIGN:
- Conductor: solid annealed copper
- Insulation: LSZH
- Pair: two conductors twisted together
- Core wrapping
- Copper tinned contact wire Ø 0,4 mm
- Core shield: aluminum polymer foil (metal outside)
- Jacket: PVC, LSZH, LSFRZH
- СOMPLIANCE WITH THE REQUIREMENTS:
- Cable: IEC 61156-5 (cat.5e)
- Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
- Fire safety: IEC 60332-1, CPR class EcaMECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius:
– During installation ≥ 8 cable diameters
– After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors: Оhm/km ≤ 95
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 5E LSZH F/UTP 4x2x24 AWG Indoor Cable
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T (up to 55 meters)
DESIGN:
- Conductor: solid annealed copper
- Insulation: solid PE
- Pair: two conductors twisted together
- Core wrapping
- Copper tinned contact wire Ø 0,4 mm
- Core shield: aluminum polymer foil (metal outside)
- Jacket: PVC, color RAL 7035
СOMPLIANCE WITH THE REQUIREMENTS:
- Cable: IEC 61156-5 (cat.5e)
- Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
- Fire safety: IEC 60332-1, CPR class EcaMECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius:
– During installation ≥ 8 cable diameters
– After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors: Оhm/km ≤ 95
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 5E F/UTP 4x2x24 AWG Outdoor Cable
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T (up to 55 meters)
DESIGN:
- Conductor: solid annealed copper
- Insulation: solid PE
- Pair: two conductors twisted together
- Core wrapping
- Jacket: PVC, color RAL 7035
- СOMPLIANCE WITH THE REQUIREMENTS:
- Cable: IEC 61156-5 (cat.5e)
- Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
- Fire safety: IEC 60332-1, CPR class Eca
MECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius:
– During installation ≥ 8 cable diameters
– After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors(-0.51 mm; -0.50mm): Оhm/km ≤ 92-95
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 5E U/UTP 4x2x24 AWG Indoor Cable
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T
- 10GBASE-T
DESIGN:
- Conductor: soft copper wire
- Insulation: PE
- Pair: two conductors twisted together:
– Pair 1: white-blue / blue
– Pair 2: white-orange / orange
– Pair 3: white-green / green
– Pair 4: white – brown / brown - Cross-web (PE or LSFRZH)
- Core wrapping
- Core shield1: aluminum polymer foil (metal outside)
- Core shield 2: tined copper braid
- Sheath: UV-stabilized PE
- MECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius: ≥ 10 cable diameters
- Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors(0,54 mm; 0,57 mm): Оhm/km ≤ 83-88
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 6 SF/UTP 4x2x23 AWG Indoor Cable
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Token Ring 16/100 Mbit/s
- Fast Ethernet (100BASE-TX)
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T
- PoE
- PoE+
- 4PPoE
DESIGN:
- Conductor: solid annealed copper
- Insulation: PE
- Pair: two conductors twisted:
- Cross-web: HDPE, 2,6×2,6 mm
- Jacket: LS0H, nominal thickness 0,5 mm; PVC, nominal thickness 0,5 mm
- STANDARDS:
- Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568.2-D
- Cable: IEC 61156-5, EN 50288-6-1
- Fire safety:LS0H jacket: EN 60332-1-2
- CPR class: Eca
- MECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius:- During installation ≥ 8 cable diameters- After installation ≥ 4 cable diameters
- Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors TPG(0,52; 0,54 mm; 0,57 mm): Оhm/km ≤ 75-82-87
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 6 U/UTP LSZH 4x2x23 AWG Indoor Cable