Specification:
- Stable Transmission
- 100% pass fluke test
- Triple Protection of Patch Cables: RJ45 modular plug, PVC Jacket and strain relief boot to increase the service life of the
- Spine-Leaf Architecture Achieve Larger Network Scale: to prevent network bottlenecks, reduce network latency, and expanding bandwidth and scalability for future network
- Widely Used in Equipment with RJ45 Ports: this cable is suitable for all devices with RJ45 jacks, such as PCs, servers, printers, routers, switches, media players, NAS, VoIP phones, PoE devices, and more.
- Provide cost-effective copper cable solutions for major corporations, medium-sized and small enterprises data centers.
CAT5E UTP Patch Cord
Catagory
CAT5EShieled
NOConductor Material
Stranded Bare CopperCable AWG
26Construction(±0.01mm)
7/0.16Connector
8P8C UTP plug; 3μm gold platingInsulation
Material
PENom. Thickness(mm)
0.14Diameter(±0.05mm)
0.77Jacket
Material
PVCNom. Thickness(mm)
0.7Diameter(±0.30mm)
5Color
Light grayELECTRICAL TEST
100% OPEN,SHORT & MISS WIRE TESTCONDUCTOR RESISTANCE
3~10 OHMS MAX.INSULATOR RESISTANCE
5M OHMS MIN.HI-POT
DC 300V 0.01secLength
0.5M/1M/2M/3M/5M (or customized length)CAT5 U/UTP Patch Cord
-
Specification:
- Stable Transmission
- 100% pass fluke test
- Triple Protection of Patch Cables: RJ45 modular plug, PVC Jacket and strain relief boot to increase the service life of the
- Spine-Leaf Architecture Achieve Larger Network Scale: to prevent network bottlenecks, reduce network latency, and expanding bandwidth and scalability for future network
- Widely Used in Equipment with RJ45 Ports: this cable is suitable for all devices with RJ45 jacks, such as PCs, servers, printers, routers, switches, media players, NAS, VoIP phones, PoE devices, and more.
- Provide cost-effective copper cable solutions for major corporations, medium-sized and small enterprises data centers.
CAT6 UTP Patch Cord
Catagory
CAT6Shieled
NOConductor Material
Stranded Bare CopperCable AWG
26Construction(±0.01mm)
7/0.16Connector
8P8C UTP plug; 3μm gold platingInsulation
Material
PENom. Thickness(mm)
0.17Diameter(±0.05mm)
0.88Jacket
Material
PVCNom. Thickness(mm)
0.7Diameter(±0.30mm)
6Color
Light grayELECTRICAL TEST
100% OPEN,SHORT & MISS WIRE TESTCONDUCTOR RESISTANCE
3~10 OHMS MAX.INSULATOR RESISTANCE
5M OHMS MIN.HI-POT
DC 300V 0.01secLength
0.25M/0.5M/1M/2M(or customized lenghth)CAT6 U/UTP Patch Cord
-
Specification:
- Stable Transmission
- 100% pass fluke test
- Triple Protection of Patch Cables: RJ45 modular plug, PVC Jacket and strain relief boot to increase the service life of the cable.
- Spine-Leaf Architecture Achieve Larger Network Scale: to prevent network bottlenecks, reduce network latency, and expanding bandwidth and scalability for future network expansion.
- Widely Used in Equipment with RJ45 Ports: this cable is suitable for all devices with RJ45 jacks, such as PCs, servers, printers, routers, switches, media players, NAS, VoIP phones, PoE devices, and more.
- Provide cost-effective copper cable solutions for major corporations, medium-sized and small enterprises data centers.
CAT6 FTP Patch Cord
Catagory
CAT6Shieled
YESConductor Material
Stranded Bare CopperCable AWG
26Construction(±0.01mm)
7/0.16Connector
8P8C FTP plug; 3μm gold platingInsulation
Material
PENom. Thickness(mm)
0.21Diameter(±0.05mm)
0.9Jacket
Material
PVCNom. Thickness(mm)
0.55Diameter(±0.30mm)
6Color
Light grayELECTRICAL TEST
100% OPEN,SHORT & MISS WIRE TESTCONDUCTOR RESISTANCE
3~10 OHMS MAX.INSULATOR RESISTANCE
5M OHMS MIN.HI-POT
DC 300V 0.01secLength
0.5M/1M/2M(or customized lenghth)CAT6 F/UTP Patch Cord
-
Specification:
- With CAT6 keystone modules, for 19″cabinet
- Complete metalation and reed
- Modularization design
- Ant-burn performance, meeting the International standard
- Label: Clear label to ensure management
- Designed by international ISO/IEC11801 and TIA/EIA5688.2
Product name
19’’ CAT6 UTP Patch panelShielded
NOPort
24-portUnit
1UIDC
Phosphor bronze and silver plating (20- 50uinch), suitable diameter 0.4-0.6mm Durability: 200 cyclesContact pin
Phosphor bronze with 3 micro-inch gold plating Mating durability: not less than 750 cyclesIntermediate Resistance
No more than 20m ohm in normal atmosphere pressure (not including bulk resistor)Insulated resistance
No less than 1,00 OM ohm in normal atmosphere pressureThe Intensity of anti-currency
DC 1,000V (AC,700V), No puncture and flash-over phenomenon In one minute. Accord with Industry standardAir pressure
70-106 KpaBack wave loss
≧34dB (1≦f<100MHZ)Relative humidity
85% (30℃)Min near end cros talk loss 100MHZ
≧43dB (100MHZ)Min far end cros talk loss 100MHZ
≧35.3dB (100MHZ)Operation temperature
-20℃ to 60℃CAT6 U/UTP Patch Panel 24 Ports 1U
-
Specification:
- With CAT6 keystone modules, for 19″cabinet
- Complete metalation and reed
- Modularization design
- Ant-burn performance, meeting the International standard
- Label: Clear label to ensure management
- Designed by international ISO/IEC11801 and TIA/EIA5688.2
Product name
19’’ CAT6 UTP Patch panelShielded
NOPort
48-portUnit
2UIDC
Phosphor bronze and silver plating (20- 50uinch), suitable diameter 0.4-0.6mm Durability: 200 cyclesContact pin
Phosphor bronze with 3 micro-inch gold plating Mating durability: not less than 750 cyclesIntermediate Resistance
No more than 20m ohm in normal atmosphere pressure(not including bulk resistor)Insulated resistance
No less than 1,00 OM ohm in normal atmosphere pressureThe Intensity of anti-currency
DC 1,000V (AC,700V), No puncture and flash-over phenomenon In one minute. Accord with Industry standardAir pressure
70-106 KpaBack wave loss
≧34dB (1≦f<100MHZ)Relative humidity
85% (30℃)Min near end cros talk loss 100MHZ
≧43dB (100MHZ)Min far end cros talk loss 100MHZ
≧35.3dB (100MHZ)Operation temperature
-20℃ to 60℃CAT6 U/UTP Patch Panel 48 Ports 2U
-
Specification:
- With CAT6 keystone modules, for 19″cabinet
- Complete metalation and reed
- Modularization design
- Ant-burn performance, meeting the International standard
- Label: Clear label to ensure management
- Designed by international ISO/IEC11801 and TIA/EIA5688.2
Product name
19’’ CAT6 FTP Patch panelShielded
YesPort
24-portUnit
1UMaterial
– Panel: 1.2mm SPCC with black color painting– RJ45 Housing: PC
– RJ45 Contatt material and finished:
Phosphor Bronze with 50-60 micro-inh Nickel plated Contact area: 3 micro-inch gold plating
– IDC house: PC, UL 94V-2 Krone
– IDC terminal material and finishing: phosphor bronze with 50 micro-inch tin-lead plated; over 50-60 micro inch nikel plating
– PCB: FR4 UL94VO
IDC Accept
22-26 AWG Stranded and solid wireRetention strength
7.7 kgs between jack and plugInsertion force
900 grms for 8 contactsDurability
Jack: 750 cycles plug-jack mating and unmating test Inseration cycles at 20 cycles/min max.Contact resistance test per 100 cycles IDC: Max. 200 punching time
Operating temperature
-40~+70 °CCAT6 F/UTP Patch Panel 24 Ports 1U
-
Specification:
- With Cat5e keystone modules, for 19″cabinet
- Complete metalation and reed
- Modularization design
- Ant-burn performance, meeting the International standard
- Label: Clear label to ensure management
- Designed by international ISO/IEC11801 and TIA/EIA5688.2
Product name
19’’ CAT5E UTP Patch panelShielded
NOPort
48-portUnit
2UIDC
Phosphor bronze and silver plating (20- 50uinch), suitable diameter 0.4-0.6mm Durability: 200 cyclesContact pin
Phosphor bronze with 3 micro-inch gold plating Mating durability: not less than 750 cyclesIntermediate Resistance
No more than 20m ohm in normal atmosphere pressure (not including bulk resistor)Insulated resistance
No less than 1,00 OM ohm in normal atmosphere pressureThe Intensity of anti-currency
DC 1,000V (AC,700V), No puncture and flash-over phenomenon In one minute. Accord with Industry standardAir pressure
70-106 KpaRelative humidity
85% (30℃)Operation temperature
-20℃ to 60℃CAT5E U/UTP Patch Panel 48 Ports 2U