-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T (up to 55 meters)
DESIGN:
- Conductor: solid annealed copper
- Insulation: solid PE
- Pair: two conductors twisted together
- Core wrapping
- Jacket: PVC, color RAL 7035
- СOMPLIANCE WITH THE REQUIREMENTS:
- Cable: IEC 61156-5 (cat.5e)
- Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
- Fire safety: IEC 60332-1, CPR class Eca
MECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius:
– During installation ≥ 8 cable diameters
– After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors(-0.51 mm; -0.50mm): Оhm/km ≤ 92-95
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 5E U/UTP 4x2x24 AWG Indoor Cable
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T (up to 55 meters)
DESIGN:
- Conductor: solid annealed copper
- Insulation: LSZH
- Pair: two conductors twisted together
- Core wrapping
- Copper tinned contact wire Ø 0,4 mm
- Core shield: aluminum polymer foil (metal outside)
- Jacket: PVC, LSZH, LSFRZH
- СOMPLIANCE WITH THE REQUIREMENTS:
- Cable: IEC 61156-5 (cat.5e)
- Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
- Fire safety: IEC 60332-1, CPR class EcaMECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius:
– During installation ≥ 8 cable diameters
– After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors: Оhm/km ≤ 95
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 5E LSZH F/UTP 4x2x24 AWG Indoor Cable
-
DESIGN
- Conductor: soft copper Diameter: 0,51 mm (±0,005 mm)
- Insulation: PE . Conductor diameter: 1,03 mm
- Pair: two conductors twisted together. Color identification of pairs: white-blue / blue and white – orange / orange
- Core wrapping
- Copper tinned contact wire Ø 0,4 mm is applied between the sheath and shield.
- Core shield: aluminum polymer foil (metal inside)
- Sheath: PE, nominal cable diameter: 6,0 mm, color: black
APPLICATION
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s,
100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s,
Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, ATM LAN 1,2 Gbit/s
СOMPLIANCE WITH THE REQUIREMENTS
ISO/IEC 11801:2002, EN 50173-1:2002, ANSI/TIA/EIA-568-B.2-1-2002, IEC 61156-5:2002, TU U 31.3-05758730-020-2002
MECHANICAL CHARACTERISTICS
Тemperature range:
During installation -10 °C … +60 °C
After installation -50 °C … +60 °C
Bending radius:
During installation ≥ 8 cable diameters After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance
Оhm/km
≤ 100Insulation resistance
GOhm/km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,65Characteristic impedance in the frequency range of:
Ohm
100±15Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20Attenuation, dB, max
2,1
4,1
6,5
8,3
9,3NEXT, dB, min
65,3
56,2
50,3
47,2
45,7PS NEXT, dB, min
62,3
53,2
47,3
44,2
42,7ELFEXT, dB, min
64
51,9
44
39,9
37,9PS ELFEXT, dB, min
61
48,9
41
36,9
34,9RL, dB, min
20
23
25
25
25Frequency, MHz
31,25
62,5
100Attenuation, dB, max
11,7
17,0
22,0NEXT, dB, min
42,8
38,3
35,3PS NEXT, dB, min
39,8
35,3
32,3ELFEXT, dB, min
34,1
28
24PS ELFEXT, dB, min
31,1
25
21RL, dB, min
23,6
21,5
20,1IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT 5 F/UTP 2x2x24 AWG outdoor
-
Application
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s
Installation and Operation Conditions
For outdoor installation in telephone ducts, collectors, mines, on the walls of buildings in conditions of heightened electro-magnetic impacts.
Operated on frequencies up to 250 MHzCompliance with the requirements
Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568-C.2
Cable: IEC 61156-2
Mechanical Characteristics
Temperature range: During installation -10 °C … +60 °C
After installation -20 °C … +60 °C
Bending radius: During installation ≥ 8 cable diameters
After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance
Оhm/km
≤ 95Insulation resistance
GOhm/km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,68Propagation delay
ns/100 m
≤ 534+36/√fDelay shift on the frequency 100 MHz
ns/100 m
≤ 30Characteristic impedance in the frequency range of:
1-100 MHz
Ohm
100±15
Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20Attenuation, dB, max:
2,1
4,1
6,5
8,3
9,3NEXT, dB, min
65,3
56,3
50,3
47,2
45,8ELFEXT, dB, min
64
52
44
40
38RL, dB, min
20,0
23,0
25,0
25,0
25,0Frequency, MHz
31,25
62,5
100Attenuation, dB, max:
11,7
17,0
22,0NEXT, dB, min
42,9
38,4
35,3ELFEXT, dB, min
34
28
24RL, dB, min
23,3
20,7
19,0IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT 5 U/UTP 2x2x24 AWG indoor
-
APPLICATION
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T
СOMPLIANCE WITH THE REQUIREMENTS
Cable: IEC 61156-5 (cat.5e)
Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
Fire safety: IEC 60332-1, CPR class Eca
MECHANICAL CHARACTERISTICS
Тemperature range:
· During installation -10 °C … +60 °C
· After installation -20 °C … +60 °C
Bending radius:· During installation ≥ 8 cable diameters
· After installation ≥ 4 cable diameters
Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance for
conductors with Ø:
0,51 mm
0,48 mm
0,46 mm
0,44 mm
Оhm/km
≤ 92
≤ 103
≤ 112
≤ 123
Insulation resistance
GOhm*km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,69Characteristic impedance in the
frequency range of: 1-100 MHz
Ohm
100±15Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20Attenuation, dB, max; for max. cable lengths with conductor Ø:
2,1
4,1
6,5
8,3
9,30,51 mm = 104 m
0,48 mm = 92 m
0,46 mm = 84 m
0,44 mm = 77 m
NEXT, dB, min
65,3
56,3
50,3
47,2
45,8PS NEXT, dB, min
62,3
53,3
47,3
44,2
42,8ELFEXT, dB, min
64
52
44
40
38PS ELFEXT, dB, min
61
49
41
37
35RL, dB, min
20,0
23,0
25,0
25,0
25,0Frequency, MHz
31,25
62,5
100Attenuation, dB, max; for max. cable lengths with conductor Ø:
11,7
17,0
22,00,51 mm = 104 m
0,48 mm = 92 m
0,46 mm = 84 m
0,44 mm = 77 m
NEXT, dB, min
42,9
38,4
35,3PS NEXT, dB, min
39,9
35,4
32,3ELFEXT, dB, min
34
28,1
24PS ELFEXT, dB, min
31
25,1
21RL, dB, min
23,6
21,5
20,1IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT 5 SF/UTP 4x2x23 AWG
-
Application:
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, ATM LAN 1,2 Gbit/s
Сompliance with the requirements:
Cable: IEC 61156-5 (cat.5e)
Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
Fire safety: IEC 60332-1, CPR class Eca
Mechanical characteristics:
Тemperature range:
- During installation -10 °C … +60 °C
- After installation -20 °C … +60 °C
Bending radius:
- During installation ≥ 8 cable diameters
- After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C:
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance for
Оhm/kmconductors with Ø:
0,51 mm
≤ 920,48 mm
≤ 1030,46 mm
≤ 1120,44 mm
≤ 123Insulation resistance
GOhm*km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,69Characteristic impedance in the
Ohm
100±15frequency range of: 1-100 MHz
Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20
31,25Attenuation, dB, max; for max. cable lengths with conductor Ø:
2,1
4,1
6,5
8,3
9,3
11,70,51 mm = 104 m
0,48 mm = 92 m
0,46 mm = 84 m
0,44 mm = 77 m
NEXT, dB, min
65,3
56,3
50,3
47,2
45,8
42,9PS NEXT, dB, min
62,3
53,3
47,3
44,2
42,8
39,9ELFEXT, dB, min
64
52
44
40
38
34PS ELFEXT, dB, min
61
49
41
37
35
31RL, dB, min
20,0
23,0
25,0
25,0
25,0
23,3Frequency, MHz
62,5
100Attenuation, dB, max; for max. cable lengths with conductor Ø:
17,0
22,00,51 mm = 104 m
0,48 mm = 92 m
0,46 mm = 84 m
0,44 mm = 77 m
NEXT, dB, min
38,4
35,3PS NEXT, dB, min
35,4
32,3ELFEXT, dB, min
28
24PS ELFEXT, dB, min
25
21RL, dB, min
20,7
19,0IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT5 F/UTP 4x2x24 AWG Indoor