• APPLICATION

    PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155

    Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, 10 Gigabit Ethernet (10GBASE-T*), ATM LAN 1,2 Gbit/s

    INSTALLATION AND OPERATION CONDITIONS

    For stationary installation inside buildings, stations, structures and equipment in conditions of heightened electromagnetic impacts. Operated on frequencies up to 250 MHz.

    СOMPLIANCE WITH THE REQUIREMENTS

    System: ISO/IEC 11801, EN 50173-1, ANSI/TIA 568-С.2 Cable: IEC 61156-5

    Fire safety: IEC 60332-1, IEC 61034-1, IEC 60754-2

    CPR class: Eca

    MECHANICAL CHARACTERISTICS

    Тemperature range:

    During installation -10 °C … +60 °C / After installation -20 °C … +60 °C

    Bending radius:

    During installation ≥ 8 cable diameters / After installation ≥ 4 cable diameters

    Tensile stress ≤ 85 N

     

    ELECTRICAL CHARACTERISTICS AT 20 °C

    Parameter
    Unit
    Value

    Capacitance
    pF/m
    ≤ 56

    Direct current resistance
    Оhm/km
    ≤ 85

    Insulation resistance
    GOhm/km
    ≥ 5

    Resistance unbalance
    %
    2

    Signal propagation velocity
    s
    0,68

    Propagation delay
    ns/100 m
    ≤ 534+36/√f

    Delay shift on the frequency 100 MHz
    ns/100 m
    ≤ 30

    Characteristic impedance in the frequency range of: 1-100 MHz

    100-250 MHz
     

    Ohm
     

    100±15

    100±22

    Test voltage between cores, (DC, 2 s)
    kV
    2,5

     

    Frequency, MHz
    1
    4
    10
    16
    20
    31,25

    Attenuation, dB, max
    2,1
    3,8
    6
    7,6
    8,5
    10,8

    NEXT, dB, min
    75,3
    66,3
    60,3
    57,3
    55,8
    52,8

    PS NEXT, dB, min
    72,3
    63,3
    57,3
    54,3
    52,8
    49,8

    ELFEXT, dB, min
    68
    56
    48
    44
    42
    38

    PS ELFEXT, dB, min
    65
    53
    45
    41
    39
    35

    RL, dB, min
    20,0
    23,0
    25,0
    25,0
    25,0
    23,6

    Frequency, MHz
    62,5
    100
    125
    200
    250

    Attenuation, dB, max
    15,5
    19,9
    22,5
    29,1
    33

    NEXT, dB, min
    48,3
    45,3
    43,8
    40,8
    39,3

    PS NEXT, dB, min
    45,3
    42,3
    40,8
    37,8
    36,3

    ELFEXT, dB, min
    32
    28
    26
    22
    20

    PS ELFEXT, dB, min
    29
    25
    23
    19
    17

    RL, dB, min
    21,5
    20,1
    19,4
    18,0
    17,3

    IEC 61156-5, values lower than 4 MHz are given for information only

    LAN Cable CAT 6 F/UTP LSZH 4x2x23 AWG

  •           APPLICATION:

    • PBX
    • V.11
    • X.21
    • ISDN
    • Ethernet (10Base-T)
    • ATM-25/52/155 Mbit/s
    • 100VG-AnyLAN
    • Fast Ethernet (100BASE-TX)
    • Token Ring 16/100 Mbit/s
    • Firewire 100 Mbit/s
    • PoE (IEEE 802.3af)
    • PoE+ (IEEE 802.3at)
    • PoE++ (IEEE 802.3bt)
    • HDBaseT
    • 1000BASE-T
    • 2.5GBASE-T
    • 5GBASE-T (up to 55 meters)

      DESIGN:
    • Conductor: solid annealed copper
    • Insulation: PE
    • Pair: two conductors twisted together:
      – Pair 1: white-blue / blue
      – Pair 2: white-orange / orange
      – Pair 3: white-green / green
      – Pair 4: white – brown / brown
    • Cross-web (PE or LSFRZH)
    • Core wrapping
    • Core shield: aluminum polymer foil (metal outside)
    • Copper tinned contact wire Ø 0,4 mm
    • Jacket: PVC, LSZH, LSFRZH
    • MECHANICAL CHARACTERISTICS:
    • Temperature range:
      – During installation -10 °C … +60 °C
      – After installation -20 °C … +60 °C
    • Bending radius: ≥ 10 cable diameters
    • Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
    • Capacitance: pF/m ≤ 56
    • Direct current resistance for conductors(0,54 mm; 0,57 mm): Оhm/km ≤ 83-88
    • Resistance unbalance: % 2
    • Insulation resistance: GOhm/km ≥ 5
    • Signal propagation velocity: % 68
    • Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
    • Test voltage between cores, (DC, 2 s): kV 2,5

    LAN Cable CAT 6 F/UTP 4x2x23 AWG Indoor Cable

  •           APPLICATION:

    • PBX
    • V.11
    • X.21
    • ISDN
    • Ethernet (10Base-T)
    • ATM-25/52/155 Mbit/s
    • 100VG-AnyLAN
    • Fast Ethernet (100BASE-TX)
    • Token Ring 16/100 Mbit/s
    • Firewire 100 Mbit/s
    • PoE (IEEE 802.3af)
    • PoE+ (IEEE 802.3at)
    • PoE++ (IEEE 802.3bt)
    • HDBaseT
    • 1000BASE-T
    • 2.5GBASE-T
    • 5GBASE-T
    • 10GBASE-T

      DESIGN:
    • Conductor: soft copper wire
    • Insulation: PE
    • Pair: two conductors twisted together:
      – Pair 1: white-blue / blue
      – Pair 2: white-orange / orange
      – Pair 3: white-green / green
      – Pair 4: white – brown / brown
    • Cross-web (PE or LSFRZH)
    • Core wrapping
    • Core shield1: aluminum polymer foil (metal outside)
    • Core shield 2: tined copper braid
    • Sheath: UV-stabilized PE
    • MECHANICAL CHARACTERISTICS:
    • Temperature range:
      – During installation -10 °C … +60 °C
      – After installation -20 °C … +60 °C
    • Bending radius: ≥ 10 cable diameters
    • Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
    • Capacitance: pF/m ≤ 56
    • Direct current resistance for conductors(0,54 mm; 0,57 mm): Оhm/km ≤ 83-88
    • Resistance unbalance: % 2
    • Insulation resistance: GOhm/km ≥ 5
    • Signal propagation velocity: % 68
    • Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
    • Test voltage between cores, (DC, 2 s): kV 2,5

    LAN Cable CAT 6 SF/UTP 4x2x23 AWG Indoor Cable

  •           APPLICATION:

    • PBX
    • V.11
    • X.21
    • ISDN
    • Ethernet (10Base-T)
    • ATM-25/52/155 Mbit/s
    • 100VG-AnyLAN
    • Token Ring 16/100 Mbit/s
    • Fast Ethernet (100BASE-TX)
    • 1000BASE-T
    • 2.5GBASE-T
    • 5GBASE-T
    • PoE
    • PoE+
    • 4PPoE

      DESIGN:
    • Conductor: solid annealed copper
    • Insulation: PE
    • Pair: two conductors twisted:
    • Cross-web: HDPE, 2,6×2,6 mm
    • Jacket: LS0H, nominal thickness 0,5 mm; PVC, nominal thickness 0,5 mm
    • STANDARDS:
    • Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568.2-D
    • Cable: IEC 61156-5, EN 50288-6-1
    • Fire safety:LS0H jacket: EN 60332-1-2
    • CPR class: Eca
    • MECHANICAL CHARACTERISTICS:
    • Temperature range:
      – During installation -10 °C … +60 °C
      – After installation -20 °C … +60 °C
    • Bending radius:- During installation ≥ 8 cable diameters- After installation ≥ 4 cable diameters
    • Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
    • Capacitance: pF/m ≤ 56
    • Direct current resistance for conductors TPG(0,52; 0,54 mm; 0,57 mm): Оhm/km ≤ 75-82-87
    • Resistance unbalance: % 2
    • Insulation resistance: GOhm/km ≥ 5
    • Signal propagation velocity: % 68
    • Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
    • Test voltage between cores, (DC, 2 s): kV 2,5

    LAN Cable CAT 6 U/UTP LSZH 4x2x23 AWG Indoor Cable