Application:
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s,
100VG-AnyLAN, Token Ring 16/100 Mbit/s, Fast Ethernet (100BASE- TX), 1000BASE-T, 2.5GBASE-T, 5GBASE-T, PoE, PoE+, PoE++
Installation and Operation conditions:
For stationary installation inside buildings, stations, structures and equipment. Op- erated on frequencies up to 250 MHz
Standads:
Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568.2-D
Cable: IEC 61156-5, EN 50288-6-1, ANSI/TIA-568.2-D
Fire safety:
- Flame propagation: EN 60332-1-2
CPR class: Eca
Mechanical characteristics:
Temperature range:
- During installation -10 °C … +60 °C
- After installation -20 °C … +60 °C
Bending radius:
- During installation ≥ 8 cable diameters
- After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
Electrical characteristics at 20 °C:
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Resistance for conductor Ø, mm:
· 0,54
Оhm/km
≤ 82Insulation resistance
GOhm*km
≥ 5Resistance unbalance
%
1Velocity of propagation (NVP)
%
70Propagation delay
ns/100 m
≤ 534+36/√fDelay skew
ns/100 m
≤ 20Characteristic impedance in the frequency range of:
· 1-100 MHz
· 101-250 MHz
Ohm
100±15
100±22
Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20
31,25Attenuation, dB, max
2,1
3,8
6
7,6
8,5
10,8NEXT, dB, min
75,3
66,3
60,3
57,3
55,8
52,8PS NEXT, dB, min
72,3
63,3
57,3
54,3
52,8
49,8ELFEXT, dB, min
68
56
48
44
42
38PS ELFEXT, dB, min
65
53
45
41
39
35RL, dB, min
20,0
23,0
25,0
25,0
25,0
23,6Frequency, MHz
62,5
100
250Attenuation, dB, max
15,5
19,9
33NEXT, dB, min
48,3
45,3
39,3PS NEXT, dB, min
45,3
42,3
36,3ELFEXT, dB, min
32
28
20PS ELFEXT, dB, min
29
25
17RL, dB, min
21,5
20,1
17,3IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT6 UTP 4x2x23 AWG Indoor
-
Application:
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T, 10GBASE-T (under 55 m)
Installation and Operation conditions:
For outdoor installation in telephone ducts, collectors, mines, on the walls of buildings in conditions of heightened electro-magnetic impacts. Operated on frequencies up to 250 MHz
Compliance with the requirements:
Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568-C.2
Cable: IEC 61156-5, EN 50288-5-1
Mechanical characteristics:
Temperature range:
- During installation -10 °C … +60 °C
- After installation -50 °C … +60 °C
Bending radius:
- During installation ≥ 8 cable diameters
- After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
Electrical characteristics at 20 °C:
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance
Оhm/km
≤ 85Insulation resistance
GOhm/km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,68Propagation delay
ns/100 m
≤ 534+36/√fDelay shift on the frequency 100 MHz
ns/100 m
≤ 30Characteristic impedance in the frequency range of:
1-100 MHz
100-250 MHz
Ohm
100±15
100±22
Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20
31,25Attenuation, dB, max
2,1
3,8
6
7,6
8,5
10,8NEXT, dB, min
75,3
66,3
60,3
57,3
55,8
52,8PS NEXT, dB, min
72,3
63,3
57,3
54,3
52,8
49,8ELFEXT, dB, min
68
56
48
44
42
38PS ELFEXT, dB, min
65
53
45
41
39
35RL, dB, min
20,0
23,0
25,0
25,0
25,0
23,6Frequency, MHz
62,5
100
250Attenuation, dB, max
15,5
19,9
33NEXT, dB, min
48,3
45,3
39,3PS NEXT, dB, min
45,3
42,3
36,3ELFEXT, dB, min
32
28
20PS ELFEXT, dB, min
29
25
17RL, dB, min
21,5
20,1
17,3IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT6 F/UTP 4x2x23 AWG Outdoor
-
APPLICATION
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155
Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, 10 Gigabit Ethernet (10GBASE-T*), ATM LAN 1,2 Gbit/s
INSTALLATION AND OPERATION CONDITIONS
For stationary installation inside buildings, stations, structures and equipment in conditions of heightened electromagnetic impacts. Operated on frequencies up to 250 MHz.
СOMPLIANCE WITH THE REQUIREMENTS
System: ISO/IEC 11801, EN 50173-1, ANSI/TIA 568-С.2 Cable: IEC 61156-5
Fire safety: IEC 60332-1, IEC 61034-1, IEC 60754-2
CPR class: Eca
MECHANICAL CHARACTERISTICS
Тemperature range:
During installation -10 °C … +60 °C / After installation -20 °C … +60 °C
Bending radius:
During installation ≥ 8 cable diameters / After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C
Parameter
Unit
ValueCapacitance
pF/m
≤ 56Direct current resistance
Оhm/km
≤ 85Insulation resistance
GOhm/km
≥ 5Resistance unbalance
%
2Signal propagation velocity
s
0,68Propagation delay
ns/100 m
≤ 534+36/√fDelay shift on the frequency 100 MHz
ns/100 m
≤ 30Characteristic impedance in the frequency range of: 1-100 MHz
100-250 MHz
Ohm
100±15
100±22
Test voltage between cores, (DC, 2 s)
kV
2,5Frequency, MHz
1
4
10
16
20
31,25Attenuation, dB, max
2,1
3,8
6
7,6
8,5
10,8NEXT, dB, min
75,3
66,3
60,3
57,3
55,8
52,8PS NEXT, dB, min
72,3
63,3
57,3
54,3
52,8
49,8ELFEXT, dB, min
68
56
48
44
42
38PS ELFEXT, dB, min
65
53
45
41
39
35RL, dB, min
20,0
23,0
25,0
25,0
25,0
23,6Frequency, MHz
62,5
100
125
200
250Attenuation, dB, max
15,5
19,9
22,5
29,1
33NEXT, dB, min
48,3
45,3
43,8
40,8
39,3PS NEXT, dB, min
45,3
42,3
40,8
37,8
36,3ELFEXT, dB, min
32
28
26
22
20PS ELFEXT, dB, min
29
25
23
19
17RL, dB, min
21,5
20,1
19,4
18,0
17,3IEC 61156-5, values lower than 4 MHz are given for information only
LAN Cable CAT 6 F/UTP LSZH 4x2x23 AWG
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T (up to 55 meters)
DESIGN:
- Conductor: solid annealed copper
- Insulation: PE
- Pair: two conductors twisted together:
– Pair 1: white-blue / blue
– Pair 2: white-orange / orange
– Pair 3: white-green / green
– Pair 4: white – brown / brown - Cross-web (PE or LSFRZH)
- Core wrapping
- Core shield: aluminum polymer foil (metal outside)
- Copper tinned contact wire Ø 0,4 mm
- Jacket: PVC, LSZH, LSFRZH
- MECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius: ≥ 10 cable diameters
- Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors(0,54 mm; 0,57 mm): Оhm/km ≤ 83-88
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 6 F/UTP 4x2x23 AWG Indoor Cable
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Fast Ethernet (100BASE-TX)
- Token Ring 16/100 Mbit/s
- Firewire 100 Mbit/s
- PoE (IEEE 802.3af)
- PoE+ (IEEE 802.3at)
- PoE++ (IEEE 802.3bt)
- HDBaseT
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T
- 10GBASE-T
DESIGN:
- Conductor: soft copper wire
- Insulation: PE
- Pair: two conductors twisted together:
– Pair 1: white-blue / blue
– Pair 2: white-orange / orange
– Pair 3: white-green / green
– Pair 4: white – brown / brown - Cross-web (PE or LSFRZH)
- Core wrapping
- Core shield1: aluminum polymer foil (metal outside)
- Core shield 2: tined copper braid
- Sheath: UV-stabilized PE
- MECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius: ≥ 10 cable diameters
- Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors(0,54 mm; 0,57 mm): Оhm/km ≤ 83-88
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 6 SF/UTP 4x2x23 AWG Indoor Cable
-
APPLICATION:
- PBX
- V.11
- X.21
- ISDN
- Ethernet (10Base-T)
- ATM-25/52/155 Mbit/s
- 100VG-AnyLAN
- Token Ring 16/100 Mbit/s
- Fast Ethernet (100BASE-TX)
- 1000BASE-T
- 2.5GBASE-T
- 5GBASE-T
- PoE
- PoE+
- 4PPoE
DESIGN:
- Conductor: solid annealed copper
- Insulation: PE
- Pair: two conductors twisted:
- Cross-web: HDPE, 2,6×2,6 mm
- Jacket: LS0H, nominal thickness 0,5 mm; PVC, nominal thickness 0,5 mm
- STANDARDS:
- Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568.2-D
- Cable: IEC 61156-5, EN 50288-6-1
- Fire safety:LS0H jacket: EN 60332-1-2
- CPR class: Eca
- MECHANICAL CHARACTERISTICS:
- Temperature range:
– During installation -10 °C … +60 °C
– After installation -20 °C … +60 °C - Bending radius:- During installation ≥ 8 cable diameters- After installation ≥ 4 cable diameters
- Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
- Capacitance: pF/m ≤ 56
- Direct current resistance for conductors TPG(0,52; 0,54 mm; 0,57 mm): Оhm/km ≤ 75-82-87
- Resistance unbalance: % 2
- Insulation resistance: GOhm/km ≥ 5
- Signal propagation velocity: % 68
- Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
- Test voltage between cores, (DC, 2 s): kV 2,5
LAN Cable CAT 6 U/UTP LSZH 4x2x23 AWG Indoor Cable