• LAN Cable CAT 6 U/UTP LSZH 4x2x23 AWG Indoor Cable

              APPLICATION:

    • PBX
    • V.11
    • X.21
    • ISDN
    • Ethernet (10Base-T)
    • ATM-25/52/155 Mbit/s
    • 100VG-AnyLAN
    • Token Ring 16/100 Mbit/s
    • Fast Ethernet (100BASE-TX)
    • 1000BASE-T
    • 2.5GBASE-T
    • 5GBASE-T
    • PoE
    • PoE+
    • 4PPoE

      DESIGN:
    • Conductor: solid annealed copper
    • Insulation: PE
    • Pair: two conductors twisted:
    • Cross-web: HDPE, 2,6×2,6 mm
    • Jacket: LS0H, nominal thickness 0,5 mm; PVC, nominal thickness 0,5 mm
    • STANDARDS:
    • Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568.2-D
    • Cable: IEC 61156-5, EN 50288-6-1
    • Fire safety:LS0H jacket: EN 60332-1-2
    • CPR class: Eca
    • MECHANICAL CHARACTERISTICS:
    • Temperature range:
      – During installation -10 °C … +60 °C
      – After installation -20 °C … +60 °C
    • Bending radius:- During installation ≥ 8 cable diameters- After installation ≥ 4 cable diameters
    • Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
    • Capacitance: pF/m ≤ 56
    • Direct current resistance for conductors TPG(0,52; 0,54 mm; 0,57 mm): Оhm/km ≤ 75-82-87
    • Resistance unbalance: % 2
    • Insulation resistance: GOhm/km ≥ 5
    • Signal propagation velocity: % 68
    • Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
    • Test voltage between cores, (DC, 2 s): kV 2,5
  • LAN Cable CAT 6 SF/UTP 4x2x23 AWG Indoor Cable

              APPLICATION:

    • PBX
    • V.11
    • X.21
    • ISDN
    • Ethernet (10Base-T)
    • ATM-25/52/155 Mbit/s
    • 100VG-AnyLAN
    • Fast Ethernet (100BASE-TX)
    • Token Ring 16/100 Mbit/s
    • Firewire 100 Mbit/s
    • PoE (IEEE 802.3af)
    • PoE+ (IEEE 802.3at)
    • PoE++ (IEEE 802.3bt)
    • HDBaseT
    • 1000BASE-T
    • 2.5GBASE-T
    • 5GBASE-T
    • 10GBASE-T

      DESIGN:
    • Conductor: soft copper wire
    • Insulation: PE
    • Pair: two conductors twisted together:
      – Pair 1: white-blue / blue
      – Pair 2: white-orange / orange
      – Pair 3: white-green / green
      – Pair 4: white – brown / brown
    • Cross-web (PE or LSFRZH)
    • Core wrapping
    • Core shield1: aluminum polymer foil (metal outside)
    • Core shield 2: tined copper braid
    • Sheath: UV-stabilized PE
    • MECHANICAL CHARACTERISTICS:
    • Temperature range:
      – During installation -10 °C … +60 °C
      – After installation -20 °C … +60 °C
    • Bending radius: ≥ 10 cable diameters
    • Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
    • Capacitance: pF/m ≤ 56
    • Direct current resistance for conductors(0,54 mm; 0,57 mm): Оhm/km ≤ 83-88
    • Resistance unbalance: % 2
    • Insulation resistance: GOhm/km ≥ 5
    • Signal propagation velocity: % 68
    • Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
    • Test voltage between cores, (DC, 2 s): kV 2,5
  • LAN Cable CAT 5E U/UTP 4x2x24 AWG Indoor Cable

              APPLICATION:

    • PBX
    • V.11
    • X.21
    • ISDN
    • Ethernet (10Base-T)
    • ATM-25/52/155 Mbit/s
    • 100VG-AnyLAN
    • Fast Ethernet (100BASE-TX)
    • Token Ring 16/100 Mbit/s
    • Firewire 100 Mbit/s
    • PoE (IEEE 802.3af)
    • PoE+ (IEEE 802.3at)
    • PoE++ (IEEE 802.3bt)
    • HDBaseT
    • 1000BASE-T
    • 2.5GBASE-T
    • 5GBASE-T (up to 55 meters)

      DESIGN:
    • Conductor: solid annealed copper
    • Insulation: solid PE
    • Pair: two conductors twisted together
    • Core wrapping
    • Jacket: PVC, color RAL 7035
    • СOMPLIANCE WITH THE REQUIREMENTS:
    • Cable: IEC 61156-5 (cat.5e)
    • Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
    • Fire safety: IEC 60332-1, CPR class Eca 

      MECHANICAL CHARACTERISTICS:

    • Temperature range:
      – During installation -10 °C … +60 °C
      – After installation -20 °C … +60 °C
    • Bending radius:
      – During installation ≥ 8 cable diameters
      – After installation ≥ 4 cable diameters
      Tensile stress ≤ 85 N

      ELECTRICAL CHARACTERISTICS AT 20 °C:
    • Capacitance: pF/m ≤ 56
    • Direct current resistance for conductors(-0.51 mm; -0.50mm): Оhm/km ≤ 92-95
    • Resistance unbalance: % 2
    • Insulation resistance: GOhm/km ≥ 5
    • Signal propagation velocity: % 68
    • Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
    • Test voltage between cores, (DC, 2 s): kV 2,5
  • LAN Cable CAT 5E F/UTP 4x2x24 AWG Outdoor Cable

              APPLICATION:

    • PBX
    • V.11
    • X.21
    • ISDN
    • Ethernet (10Base-T)
    • ATM-25/52/155 Mbit/s
    • 100VG-AnyLAN
    • Fast Ethernet (100BASE-TX)
    • Token Ring 16/100 Mbit/s
    • Firewire 100 Mbit/s
    • PoE (IEEE 802.3af)
    • PoE+ (IEEE 802.3at)
    • PoE++ (IEEE 802.3bt)
    • HDBaseT
    • 1000BASE-T
    • 2.5GBASE-T
    • 5GBASE-T (up to 55 meters)

      DESIGN:
    • Conductor: solid annealed copper
    • Insulation: solid PE
    • Pair: two conductors twisted together
    • Core wrapping
    • Copper tinned contact wire Ø 0,4 mm
    • Core shield: aluminum polymer foil (metal outside)
    • Jacket: PVC, color RAL 7035

      СOMPLIANCE WITH THE REQUIREMENTS:

    • Cable: IEC 61156-5 (cat.5e)
    • Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
    • Fire safety: IEC 60332-1, CPR class EcaMECHANICAL CHARACTERISTICS:
    • Temperature range:
      – During installation -10 °C … +60 °C
      – After installation -20 °C … +60 °C
    • Bending radius:
      – During installation ≥ 8 cable diameters
      – After installation ≥ 4 cable diameters
      Tensile stress ≤ 85 N

      ELECTRICAL CHARACTERISTICS AT 20 °C:
    • Capacitance: pF/m ≤ 56
    • Direct current resistance for conductors: Оhm/km ≤ 95
    • Resistance unbalance: % 2
    • Insulation resistance: GOhm/km ≥ 5
    • Signal propagation velocity: % 68
    • Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
    • Test voltage between cores, (DC, 2 s): kV 2,5
  • LAN Cable CAT 5E LSZH F/UTP 4x2x24 AWG Indoor Cable

              APPLICATION:

    • PBX
    • V.11
    • X.21
    • ISDN
    • Ethernet (10Base-T)
    • ATM-25/52/155 Mbit/s
    • 100VG-AnyLAN
    • Fast Ethernet (100BASE-TX)
    • Token Ring 16/100 Mbit/s
    • Firewire 100 Mbit/s
    • PoE (IEEE 802.3af)
    • PoE+ (IEEE 802.3at)
    • PoE++ (IEEE 802.3bt)
    • HDBaseT
    • 1000BASE-T
    • 2.5GBASE-T
    • 5GBASE-T (up to 55 meters)

      DESIGN:
    • Conductor: solid annealed copper
    • Insulation: LSZH
    • Pair: two conductors twisted together
    • Core wrapping
    • Copper tinned contact wire Ø 0,4 mm
    • Core shield: aluminum polymer foil (metal outside)
    • Jacket: PVC, LSZH, LSFRZH
    • СOMPLIANCE WITH THE REQUIREMENTS:
    • Cable: IEC 61156-5 (cat.5e)
    • Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)
    • Fire safety: IEC 60332-1, CPR class EcaMECHANICAL CHARACTERISTICS:
    • Temperature range:
      – During installation -10 °C … +60 °C
      – After installation -20 °C … +60 °C
    • Bending radius:
      – During installation ≥ 8 cable diameters
      – After installation ≥ 4 cable diameters
      Tensile stress ≤ 85 N

      ELECTRICAL CHARACTERISTICS AT 20 °C:
    • Capacitance: pF/m ≤ 56
    • Direct current resistance for conductors: Оhm/km ≤ 95
    • Resistance unbalance: % 2
    • Insulation resistance: GOhm/km ≥ 5
    • Signal propagation velocity: % 68
    • Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15
    • Test voltage between cores, (DC, 2 s): kV 2,5
  • CCTV Cable 1+4 Mini U4 2×0,50 500M

    • Impendance: 75+/-3 Ohm
    • Capacity: 55+/-3 pF/m
    • Velocity ratio: 80 %
    • DC resistance (20 ºC) Conductor: 63,1 Ohm/km
      Outer shield: 40,6 Ohm/km
    • Attenuation (20 ºC): 5 MHz 2,62 dB/100 m
      50 MHz 8,40 dB/100 m
      200 MHz 16,87 dB/100 m
      470 MHz 25,97 dB/100 m
      500 MHz 26,80 dB/100 m
      862 MHz 35,32 dB/100 m
      1000 MHz 38,09 dB/100 m
    • Return loss at: 30-470 MHz dB >20
      470-862 MHz dB >23
      862-2150 MHz dB  >18
    • Screening efficiency: 5-10 MHz dB >70
      10-30 MHz dB >80
      30-1000 MHz dB >85
  • LAN Cable CAT 6 F/UTP 4x2x23 AWG Indoor Cable

              APPLICATION:

    • PBX
    • V.11
    • X.21
    • ISDN
    • Ethernet (10Base-T)
    • ATM-25/52/155 Mbit/s
    • 100VG-AnyLAN
    • Fast Ethernet (100BASE-TX)
    • Token Ring 16/100 Mbit/s
    • Firewire 100 Mbit/s
    • PoE (IEEE 802.3af)
    • PoE+ (IEEE 802.3at)
    • PoE++ (IEEE 802.3bt)
    • HDBaseT
    • 1000BASE-T
    • 2.5GBASE-T
    • 5GBASE-T (up to 55 meters)

      DESIGN:
    • Conductor: solid annealed copper
    • Insulation: PE
    • Pair: two conductors twisted together:
      – Pair 1: white-blue / blue
      – Pair 2: white-orange / orange
      – Pair 3: white-green / green
      – Pair 4: white – brown / brown
    • Cross-web (PE or LSFRZH)
    • Core wrapping
    • Core shield: aluminum polymer foil (metal outside)
    • Copper tinned contact wire Ø 0,4 mm
    • Jacket: PVC, LSZH, LSFRZH
    • MECHANICAL CHARACTERISTICS:
    • Temperature range:
      – During installation -10 °C … +60 °C
      – After installation -20 °C … +60 °C
    • Bending radius: ≥ 10 cable diameters
    • Tensile stress ≤ 85 NELECTRICAL CHARACTERISTICS AT 20 °C:
    • Capacitance: pF/m ≤ 56
    • Direct current resistance for conductors(0,54 mm; 0,57 mm): Оhm/km ≤ 83-88
    • Resistance unbalance: % 2
    • Insulation resistance: GOhm/km ≥ 5
    • Signal propagation velocity: % 68
    • Characteristic impedance in the frequency range: 1-100 MHz 100 +/-15,22
    • Test voltage between cores, (DC, 2 s): kV 2,5
  • LAN Cable CAT 6 F/UTP LSZH 4x2x23 AWG

    APPLICATION

    PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155

    Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, 10 Gigabit Ethernet (10GBASE-T*), ATM LAN 1,2 Gbit/s

    INSTALLATION AND OPERATION CONDITIONS

    For stationary installation inside buildings, stations, structures and equipment in conditions of heightened electromagnetic impacts. Operated on frequencies up to 250 MHz.

    СOMPLIANCE WITH THE REQUIREMENTS

    System: ISO/IEC 11801, EN 50173-1, ANSI/TIA 568-С.2 Cable: IEC 61156-5

    Fire safety: IEC 60332-1, IEC 61034-1, IEC 60754-2

    CPR class: Eca

    MECHANICAL CHARACTERISTICS

    Тemperature range:

    During installation -10 °C … +60 °C / After installation -20 °C … +60 °C

    Bending radius:

    During installation ≥ 8 cable diameters / After installation ≥ 4 cable diameters

    Tensile stress ≤ 85 N

     

    ELECTRICAL CHARACTERISTICS AT 20 °C

    Parameter
    Unit
    Value

    Capacitance
    pF/m
    ≤ 56

    Direct current resistance
    Оhm/km
    ≤ 85

    Insulation resistance
    GOhm/km
    ≥ 5

    Resistance unbalance
    %
    2

    Signal propagation velocity
    s
    0,68

    Propagation delay
    ns/100 m
    ≤ 534+36/√f

    Delay shift on the frequency 100 MHz
    ns/100 m
    ≤ 30

    Characteristic impedance in the frequency range of: 1-100 MHz

    100-250 MHz
     

    Ohm
     

    100±15

    100±22

    Test voltage between cores, (DC, 2 s)
    kV
    2,5

     

    Frequency, MHz
    1
    4
    10
    16
    20
    31,25

    Attenuation, dB, max
    2,1
    3,8
    6
    7,6
    8,5
    10,8

    NEXT, dB, min
    75,3
    66,3
    60,3
    57,3
    55,8
    52,8

    PS NEXT, dB, min
    72,3
    63,3
    57,3
    54,3
    52,8
    49,8

    ELFEXT, dB, min
    68
    56
    48
    44
    42
    38

    PS ELFEXT, dB, min
    65
    53
    45
    41
    39
    35

    RL, dB, min
    20,0
    23,0
    25,0
    25,0
    25,0
    23,6

    Frequency, MHz
    62,5
    100
    125
    200
    250

    Attenuation, dB, max
    15,5
    19,9
    22,5
    29,1
    33

    NEXT, dB, min
    48,3
    45,3
    43,8
    40,8
    39,3

    PS NEXT, dB, min
    45,3
    42,3
    40,8
    37,8
    36,3

    ELFEXT, dB, min
    32
    28
    26
    22
    20

    PS ELFEXT, dB, min
    29
    25
    23
    19
    17

    RL, dB, min
    21,5
    20,1
    19,4
    18,0
    17,3

    IEC 61156-5, values lower than 4 MHz are given for information only

  • LAN Cable CAT 5 F/UTP 2x2x24 AWG outdoor

    DESIGN

    1. Conductor: soft copper Diameter: 0,51 mm (±0,005 mm)
    2. Insulation: PE . Conductor diameter: 1,03 mm
    3. Pair: two conductors twisted together. Color identification of pairs: white-blue / blue and white – orange / orange
    4. Core wrapping
    5. Copper tinned contact wire Ø 0,4 mm is applied between the sheath and shield.
    6. Core shield: aluminum polymer foil (metal inside)
    7. Sheath: PE, nominal cable diameter: 6,0 mm, color: black

    APPLICATION

    PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s,

    100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s,

    Gigabit Ethernet (1000BASE-T), Firewire 100 Mbit/s, ATM LAN 1,2 Gbit/s

    СOMPLIANCE WITH THE REQUIREMENTS

    ISO/IEC 11801:2002, EN 50173-1:2002, ANSI/TIA/EIA-568-B.2-1-2002, IEC 61156-5:2002, TU U 31.3-05758730-020-2002

    MECHANICAL CHARACTERISTICS

    Тemperature range:

    During installation -10 °C … +60 °C

    After installation -50 °C … +60 °C

    Bending radius:

    During installation ≥ 8 cable diameters After installation ≥ 4 cable diameters

    Tensile stress ≤ 85 N

    ELECTRICAL CHARACTERISTICS AT 20 °C

    Parameter
    Unit
    Value

    Capacitance
    pF/m
    ≤ 56

    Direct current resistance
    Оhm/km
    ≤ 100

    Insulation resistance
    GOhm/km
    ≥ 5

    Resistance unbalance
    %
    2

    Signal propagation velocity
    s
    0,65

    Characteristic impedance in the frequency range of:
    Ohm
    100±15

    Test voltage between cores, (DC, 2 s)
    kV
    2,5

     

    Frequency, MHz
    1
    4
    10
    16
    20

    Attenuation, dB, max
    2,1
    4,1
    6,5
    8,3
    9,3

    NEXT, dB, min
    65,3
    56,2
    50,3
    47,2
    45,7

    PS NEXT, dB, min
    62,3
    53,2
    47,3
    44,2
    42,7

    ELFEXT, dB, min
    64
    51,9
    44
    39,9
    37,9

    PS ELFEXT, dB, min
    61
    48,9
    41
    36,9
    34,9

    RL, dB, min
    20
    23
    25
    25
    25

    Frequency, MHz
    31,25
    62,5
    100

    Attenuation, dB, max
    11,7
    17,0
    22,0

    NEXT, dB, min
    42,8
    38,3
    35,3

    PS NEXT, dB, min
    39,8
    35,3
    32,3

    ELFEXT, dB, min
    34,1
    28
    24

    PS ELFEXT, dB, min
    31,1
    25
    21

    RL, dB, min
    23,6
    21,5
    20,1

    IEC 61156-5, values lower than 4 MHz are given for information only

  • LAN Cable CAT 5 U/UTP 2x2x24 AWG indoor

    Application

    PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s

    Installation and Operation Conditions

    For outdoor installation in telephone ducts, collectors, mines, on the walls of buildings in conditions of heightened electro-magnetic impacts.
    Operated on frequencies up to 250 MHz

    Compliance with the requirements

    Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568-C.2

    Cable: IEC 61156-2

    Mechanical Characteristics

    Temperature range:    During installation -10 °C … +60 °C

    After installation -20 °C … +60 °C

    Bending radius:            During installation ≥ 8 cable diameters

    After installation ≥ 4 cable diameters

    Tensile stress ≤ 85 N

     

    ELECTRICAL CHARACTERISTICS AT 20 °C

    Parameter
    Unit
    Value

    Capacitance
    pF/m
    ≤ 56

    Direct current resistance
    Оhm/km
    ≤ 95

    Insulation resistance
    GOhm/km
    ≥ 5

    Resistance unbalance
    %
    2

    Signal propagation velocity
    s
    0,68

    Propagation delay
    ns/100 m
    ≤ 534+36/√f

    Delay shift on the frequency 100 MHz
    ns/100 m
    ≤ 30

    Characteristic impedance in the frequency range of:

    1-100 MHz
     

    Ohm
     

    100±15

    Test voltage between cores, (DC, 2 s)
    kV
    2,5

     

    Frequency, MHz
    1
    4
    10
    16
    20

    Attenuation, dB, max:
    2,1
    4,1
    6,5
    8,3
    9,3

    NEXT, dB, min
    65,3
    56,3
    50,3
    47,2
    45,8

    ELFEXT, dB, min
    64
    52
    44
    40
    38

    RL, dB, min
    20,0
    23,0
    25,0
    25,0
    25,0

    Frequency, MHz
    31,25
    62,5
    100

    Attenuation, dB, max:
    11,7
    17,0
    22,0

    NEXT, dB, min
    42,9
    38,4
    35,3

    ELFEXT, dB, min
    34
    28
    24

    RL, dB, min
    23,3
    20,7
    19,0

    IEC 61156-5, values lower than 4 MHz are given for information only

     

  • LAN Cable CAT 5 SF/UTP 4x2x23 AWG

    APPLICATION

    PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T

    СOMPLIANCE WITH THE REQUIREMENTS

    Cable: IEC 61156-5 (cat.5e)

    Cabling: ISO/IEC 11801-1 & EN 50173-1 (class D), ANSI/TIA 568-С.2 (cat.5e)

    Fire safety: IEC 60332-1, CPR class Eca

    MECHANICAL CHARACTERISTICS

    Тemperature range:

    · During installation -10 °C … +60 °C

    · After installation -20 °C … +60 °C
    Bending radius:

    · During installation ≥ 8 cable diameters

    · After installation ≥ 4 cable diameters
    Tensile stress ≤ 85 N

     

    ELECTRICAL CHARACTERISTICS AT 20 °C

    Parameter
    Unit
    Value

    Capacitance
    pF/m
    ≤ 56

    Direct current resistance for

    conductors with Ø:

    0,51 mm

    0,48 mm

    0,46 mm

    0,44 mm
    Оhm/km
     

     

    ≤ 92

    ≤ 103

    ≤ 112

    ≤ 123

    Insulation resistance
    GOhm*km
    ≥ 5

    Resistance unbalance
    %
    2

    Signal propagation velocity
    s
    0,69

    Characteristic impedance in the

    frequency range of: 1-100 MHz
    Ohm
    100±15

    Test voltage between cores, (DC, 2 s)
    kV
    2,5

     

    Frequency, MHz
    1
    4
    10
    16
    20

    Attenuation, dB, max; for max. cable lengths with conductor Ø:
    2,1
    4,1
    6,5
    8,3
    9,3

    0,51 mm = 104 m

    0,48 mm = 92 m

    0,46 mm = 84 m

    0,44 mm = 77 m

    NEXT, dB, min
    65,3
    56,3
    50,3
    47,2
    45,8

    PS NEXT, dB, min
    62,3
    53,3
    47,3
    44,2
    42,8

    ELFEXT, dB, min
    64
    52
    44
    40
    38

    PS ELFEXT, dB, min
    61
    49
    41
    37
    35

    RL, dB, min
    20,0
    23,0
    25,0
    25,0
    25,0

    Frequency, MHz
    31,25
    62,5
    100

    Attenuation, dB, max; for max. cable lengths with conductor Ø:
    11,7
    17,0
    22,0

    0,51 mm = 104 m

    0,48 mm = 92 m

    0,46 mm = 84 m

    0,44 mm = 77 m

    NEXT, dB, min
    42,9
    38,4
    35,3

    PS NEXT, dB, min
    39,9
    35,4
    32,3

    ELFEXT, dB, min
    34
    28,1
    24

    PS ELFEXT, dB, min
    31
    25,1
    21

    RL, dB, min
    23,6
    21,5
    20,1

    IEC 61156-5, values lower than 4 MHz are given for information only

  • Loudspeaker cable 2×0,75 mm²

    Application

    Designed for connection home acoustics (speakers, music centers, home cinemas), lengthening speaker cords.

    Cable design

    1. Conductor: copper wire (conductor structure complies with VDE 0295 class 6)
    2. Sheath: ion stable PVC (transparent with a longitudinal black stripe).

    Installation and operation conditions

    Temp Rating:

    • Installation Temp Rating: -10 °C … +50 °C;
    • Operating Temp Range: -20 °C … +70 °C.

    Min Bend Radius: 5 cable diameters.

    Main technical and mechanical characteristics

    Cable brand                                          Resistance, Ohm/km     Capacitance, pF/m     Inductance, mH/k

    Loudspeaker Cable 2*0,75 Hi-Fi
    23,5                               60                                     0,61

     

    Nomenclature and mass-dimensional characteristics

    Cable brand                                                     Outside diameter, mm                            Weight, kg/km

    Loudspeaker Cable 2*0,75 Hi-Fi
    2,5х5,4
    27,1

  • Loudspeaker cable 2×1,5 mm²

    Application

    Designed for connection home acoustics (speakers, music centers, home cinemas), lengthening speaker cords.

    Cable design

    1. Conductor: copper wire (conductor structure complies with VDE 0295 class 6)
    2. Sheath: ion stable PVC (transparent with a longitudinal black stripe).

    Installation and operation conditions

    Temp Rating:

    • Installation Temp Rating: -10 °C … +50 °C;
    • Operating Temp Range: -20 °C … +70 °C.

    Min Bend Radius: 5 cable diameters.

    Main technical and mechanical characteristics

    Cable brand                                          Resistance, Ohm/km     Capacitance, pF/m     Inductance, mH/k

    Loudspeaker Cable 2*0,75 Hi-Fi
    12,5                              67                                     0,54

     

    Nomenclature and mass-dimensional characteristics

    Cable brand                                                     Outside diameter, mm                            Weight, kg/km

    Loudspeaker Cable 2*0,75 Hi-Fi
    3,5х7,4
    54,7

  • Fiber Optic Cable Armoured 9125 outdoor Uni-tube

    Optics Specifications

    Attenuation(dB/km)
    @1310nm
    ≤0.34db/km

    @1383nm (after hydrogen aging)
    ≤0.32db/km

    @1550nm
    ≤0.20db/km

    @1625nm
    ≤0.24db/km

    Dispersion
    @1285nm~1340nm
    -3.0~3.0ps/(nm*km)

    @1550nm
    ≤18ps/(nm*km)

    @1625nm
    ≤22ps/(nm*km)

    Zero-Dispersion wavelength
    1300~1324nm

    Zero-Dispersion slope
    ≤0.092ps/(nm2*km)

    Mode field diameter @ 1310nm
    9.2±0.4μm

    Mode field diameter @ 1550nm
    10.4±0.8μm

    PMD
    Max. value for fiber on the reel
    0.2ps/km 1/2

    Max. Designed value for link
    0.08ps/km 1/2

    Cable cutoff wavelength,λ cc
    ≤1260nm

    Effective group index(Neff)@1310nm
    1.4675

    Effective group index(Neff)@1550nm
    1.4680

    Macro-bend loss(Φ60mm,100 turns)@1550nm
    ≤0.05db

    Back scatter characteristic(@1310nm&1550nm)

    Point discontinuity
    ≤0.05db

    Attenuation uniformity
    ≤0.05db/km

    Attenuation coefficient difference for bi-directional measurement
    ≤0.05db/km

    Geometrical characteristics

    Cladding diameter
    125±1μm

    Cladding non-circularity
    ≤1%

    Core/cladding concentricity error
    ≤0.4μm

    Fiber diameter with coating(uncolored)
    245±5μm

    Cladding/coating concentricity error
    ≤12.0μm

    Curl
    ≥4m

    Mechanical characteristic

    Proof test
    0.69GPa

    Coating strip force(typical value)
    1.4N

    Dynamic stress corrosion susceptibility parameter(typical value)
    ≥20

    Environmental characteristics(@1310nm&1550nm)

    Temperature induced attenuation(-60~+85℃)
    ≤0.5dB/km

    Dry heat induced attenuation(85±2℃,30days)
    ≤0.5dB/km

    Water immersion induced attenuation(23±2℃,30days)
    ≤0.5dB/km

    Damp heat induced attenuation(85±2℃,RH85%,30days)
    ≤0.5dB/km

     

     

    Fiber count
    2
    4
    6
    8
    12

    Fiber No. per tube
    2
    4
    6
    8
    12

    Loose tube diameter/Material
    2.2+0.2mm/PBT

    Outer sheath thickness &Material
    1.5-1.8mm   HDPE

    Strength member
    Steel tape +Two steel wire

    Cable overall diameter
    8.5±0.2mm

    Cable weight
    Approx 65 kg/km

    Operation temperature range
    -40 ℃ to + 70 ℃

    Installation temperature range
    -40   ℃ to + 70 ℃

    Transport and storage temperature

    range
    – 40 ℃ to + 70 ℃

    Allowable Tensile Load(N)
    2000N

    Crush resistance
    Short term :2200N/100MM    Long term:

    1100N/100MM

    Minimal installation bending radius
    20 x OD

    Minimal operation bending radius
    10 x OD

  • CCTV Cable RG59 1+2 2×0,75 outdoor 500m

    Electric parameters:

    Impedance

    Ohm
    75+/-3

    Capacity

    pF/m
    54.5+/-3

    Velocity ratio

    %
    85

    DC resistance (20 ºC)
    Conductor
    Ohm/km
    35.5

    Outer shield
    Ohm/km
    31

    Attenuation (20 ºC)
    1 MHz
    db/100 m
    0.87

    5 MHz
    db/100 m
    1.98

    10 MHz
    db/100 m
    2.79

    50 MHz
    db/100 m
    6.25

    100 MHz
    db/100 m
    8.91

    200 MHz
    db/100 m
    12.9

    300 MHz
    db/100 m
    15.83

    470 MHz
    db/100 m
    19.41

    862 MHz
    db/100 m
    26.14

    1000 MHz
    db/100 m
    28.92

    1350 MHz
    db/100 m

    1750 MHz
    db/100 m

    2150 MHz
    db/100 m

    Return loss at
    30-470 MHz
    db
    >23

    470-862 MHz
    db
    >20

    682-2150 MHz
    db
    >18

    Screening efficiency
    5-10 MHz
    db
    >55

    10-30 MHz
    db
    >60

    30-1000 MHz
    db
    >65

    Construction:

    Material conductor

    Bare copper

    Diameter conductor
    mm
    0.8

    Material dielectric

    FHDPE

    Diameter dielectric
    mm
    3,7±0,15

    Typf of foil

    Al/Pet/Al

    Braiding material

    AM (aluminium)

    Braid coverage
    %
    67

    Power wires

    Copper (2 x 0,75 mm2)

    Outer jacket

    PVC

    Diameter sheath
    mm
    6.1/12.0

    Min. Setting radius
    mm
    35