LAN Cable CAT6 F/UTP 4x2x23 AWG Outdoor Aerial

Application

  • PBX, 11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Token Ring 16/100 Mbit/s
  • Fast Ethernet (100BASE-TX), Gigabit Ethernet (1000BASE-T), 2,5 Gbit/s Ethernet (2.5GBASE-T) and 5 Gbit/s (5GBASE-T)
  • PoE, PoE+, PoE++

Installation and Operation Conditions

To provide support for aerial outdoor applications in conditions of height- ened electromagnetic impacts. Operated on frequencies up to 250 MHz

Compliance with the requirements

Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568.2-D

Cable: IEC 61156-5, EN 50288-5-1, ANSI/TIA-568.2-D

CPR euroclass: Fca

Categories: , ,

Mechanical characteristics

Temperature range:

  • During installation -10 °C … +60 °C
  • After installation -50 °C … +60 °C

Bending radius:

  • During installation ≥ 10 cable diameters
  • After installation ≥ 4 cable diameters

Tensile strength: ≤ 1200 N

Electrical characteristics at 20 °C, 100 M

Parameter Unit Value
Capacitance pF/m ≤ 56
Direct current resistance Оhm/km ≤ 95
Insulation resistance GOhm/km ≥ 5
Resistance unbalance % 2
NVP % 68
Propagation delay ns/100 m ≤ 534+36/√f
Delay skew on the frequency 100 MHz ns/100 m ≤ 30
Characteristic impedance in the frequency range of:

1-250 MHz

 

Ohm

 

100±15

Test voltage between cores, (DC, 2 s) kV 2,5

 

TRANSMISSION CHARACTERISTICS AT 20 °C, 100 M

Frequency, MHz 1 4 10 16 20 31,25 62,5 100 250
Attenuation, dB, max 2,1 3,8 6 7,6 8,5 10,8 15,5 19,9 33
NEXT, dB, min 75,3 66,3 60,3 57,3 55,8 52,8 48,3 45,3 39,3
PS NEXT, dB, min 72,3 63,3 57,3 54,3 52,8 49,8 45,3 42,3 36,3
ELFEXT, dB, min 68 56 48 44 42 38 32 28 20
PS ELFEXT, dB, min 65 53 45 41 39 35 29 25 17
RL, dB, min 20,0 23,0 25,0 25,0 25,0 23,6 21,5 20,1 17,3